Advantech INTRAC-305 user manual Contrast & Brightness, Home Function System Setup Enter

Page 40

OPERATION

INTRAC-305

CONTRAST & BRIGHTNESS

Function

Standby

Home

Contrast adjust

Bright adjust

Normal

Next

Field

Press Enter to store values

1

2

3

4

5

6

puts the antenna control system into STANDBY mode and skips to the HOME menu

skips to the Home (root) menu

adjusts contrast of LCD display panel

adjusts brightness of LCD display panel

restores factory defined baseline settings

moves the highlight box to the next field in the current menu

Path

HOME - FUNCTION - SYSTEM SETUP - ENTER

or

From Models or Configuration

 

SYSTEM SETUP - ENTER

Description

The screen Contrast and Brightness can be adjusted in this

 

menu.

 

The Contrast range is from 0 to 15 and the Brightness range

 

is from 0 to 8.

 

The levels are set using Menu Key 3 for contrast and Menu

 

Key 4 for brightness.

 

Each press of a key increases the displayed number by one

 

and the screen brightness or contrast changes.

 

When the display is at its most visible press ENTER to store

 

the values.

 

Menu Key 5 (Normal) sets the Brightness and Contrast to the

 

default values which are 8 in both cases.

Note

The Flicker setting is not an operator controllable parameter.

Page 28

INTRAC-305 MANUAL - Issue 3.2

©2011 Advantech Wireless

Image 40
Contents INTRAC-305 PrefacePreface PrefaceManual Sections INTRAC-305 Contents INTRAC-305 SubjectContents InstallationIntroducing the INTRAC-305 Introduction INTRAC-305Introduction Retro FittingIquick Start Guide INTRAC-305 Quick Start Guide Safety Safety INTRAC-305Electrical Do not Place in Normal Garbage or in a FireMechanical SafetyEMC Page Specification & Options Specification & OptionsRequired Mechanical Characteristics of the Antenna System Specification Specification & Options INTRAC-305Do not Mount by Front Panel Lugs Alone Voltage Serial InterfacesINTRAC-305 Deliberately blank Operation Operating the INTRAC-305Front Panel Operation INTRAC-305 Menu StructureSystem Setup FunctionNext Field EnterAlphabetical Index of Menus INTRAC-305 Home HomeStandby StandbyNEW Mode Goto Auto Continue New ModelHome NEW Mode Menu KEY MANUAL/STOWGoto Position Operation SearchGoto Satellite Auto Continue Auto NEW Model Function Configuration When IT is Required to Control the Intrac fromRemote Terminal Diagnostics Must be Switched OFFBeacon Frequency Home Function Menu KEY 6 EnterEdit Satellite Table Config Menu KEY 6 X2 EnterHome Function Menu KEY 6 X2 Enter Soft Limits Drive in Manual Mode is not Inhibited bySoft Limits X2 Setup X2 Resolver SetupDiagnostics on / Diagnostics OFF Diagnostics OnBeacon Threshold System Setup Enter Home Function System Setup EnterContrast & Brightness Home Function System Setup Fine Tune senseFine Tune Offsets Azimuth true Elevation invStation CO-ORDINATES Date & Time Time Rate Correction AZ & EL Beamwidth Stow Setup Select Stow USE UsedFitted Options Home Function Models Enter Rapid Model GenerateModels Enter Home Function Models Menu KEY 6 Enter Program TrackModels Menu KEY 6 Enter Reserve Model Home Function ModelsINTRAC-305EDIT IESS-412 Edit Norad Buffer Edit Star Track Edit Satellite Table Clear Models Intrac IESS-412Show Alarms MoreREMOTE/LOCAL Normal Operation Alarms & Errors Alarms & ErrorsPrimary Alarms Alarms & Errors INTRAC-305 Secondary AlarmsAlarm Outputs Recovering from AlarmsINTRAC-305 Alarms & Errors ErrorsPower Failure IESS-412 DataDeliberately blank Technical Description Technical DescriptionTechnical Description INTRAC-305 Modes Auto normal operating mode Technical Description72hrs, the beacon is still not producing a useful signal* Using either IESS-412 or Norad data. see Reserve ModelWhere the satellite’s position is only roughly known search High accuracy of the model the tracking is within 0.05dBEnters Standby. The antenna can then be peaked using Manual mode or search mode see below before selectingManually or in search mode see below. To commence During those scans and phase two of the search isUsing IESS-412 or Norad Data Than two places of decimals LMO value is given in the range -180to +180.Epoch XNDT20XNDD60 BstarAntenna Motion Limits Tracking Signal Axes PositionTechnical Description INTRAC-305 Installation InstallationInstallation INTRAC-305 Connections generalConnections Block Diagram InstallationRear Panel Layout Connector PIN Allocations Intractm 305 Resolvers ConnectorSignals to the Motor Drive Cabinet Motor ControlCommunication Ports Stp-Trk Inputs / Alarm outputsRemote Port Test Port 1 & 2 RS423 Test Port 1 & 2 RS422Data can be monitored during remote operation by using a Second PC connected to Test PortINTRAC-305 Installation Tracking Signal Input Tracking signal may be provided as a dc voltage from anEmergency Stop switch is released Appropriate drive command re-instatedOperational Checks Manual OperationRemote Control Auto OperationFault Finding Fault FindingFault Finding INTRAC-305 Fault SymptomsTo power up Intrac doesn’t appearTWO Part Retaining PIN System Alarm indicator to illuminate and the Intrac to Enter Standby ModeSwitch consists of two normally closed N.C. contacts Pressing the switch opens both sets of contacts. The switchNo Antenna Drive ExampleFault Finding INTRAC-305 Warranty & Repair Warranty & RepairWarranty Repair ServiceAMT Limited will investigate the fault, determine the most Effective repair technique and issue a repair cost estimateCustomer either by a Purchase Order or through a Repair Contract