Advantech INTRAC-305 user manual Operation, Search

Page 29

INTRAC-305

SEARCH

3

OPERATION

Current Mode

Tracking

Control State

Local

Beac Freq

11.500000GHz

El Angle

25.55°

Az Angle

235.45°

Pol Angle

25.63°

SEARCH

 

Nom. Angle

 

Box Size

 

 

 

 

2.0°

El

-027.334°

 

 

 

 

 

 

Az

178.550°

2.0°

Dwell Time

25secs

Beac Freq 12.250500GHz Press EN to begin search

Mode

Standby

Home

Goto

Position

Goto

Satellite

Next

Field

1

2

3

4

5

6

puts the antenna control system into STANDBY mode and skips to the HOME menu

skips to the Home (root) menu

skips to the Goto Position menu

(not used)

skips to the Goto Satellite menu

moves the highlight box to the next field in the current menu

Path

HOME - NEW MODE - GOTO (Position) - MENU KEY 4

Description

Used to search a specific area of sky for the strongest signal

 

on the beacon frequency.

 

The antenna may be driven to the nominal co-ordinates of the

 

required satellite by either the Goto Position or Goto Satellite

 

commands or manually. Alternatively the Az & El co-

 

ordinates can be entered on this screen.

 

Using Menu Key 6 (Next Field) and the numeric keys the

 

satellite's position and beacon frequency may be entered.

 

The search box size and the antenna dwell time are also

 

entered in the same manner.

 

The box size parameters are either side of the nominal angle

 

thus entering 2° will cause a 4° scan.

 

The dwell time is the time that the antenna will remain at each

 

step. It is the lock time of the beacon receiver. For the IBR-L

 

(The Signal Processors supplied Integrated Beacon Receiver)

 

the default dwell time of 25 seconds is correct.

 

Once all the co-ordinates are set pressing ENTER will start

 

the search. The antenna will drive to the nearest corner of

 

the search box before commencing the search pattern.

© 2011 Advantech Wireless

INTRAC-305 MANUAL - Issue 3.2

Page 17

Image 29
Contents Preface INTRAC-305Manual Sections PrefacePreface INTRAC-305 Subject Contents INTRAC-305Installation ContentsIntroduction INTRAC-305 Introducing the INTRAC-305Retro Fitting IntroductionIquick Start Guide INTRAC-305 Quick Start Guide Safety INTRAC-305 SafetyElectrical Do not Place in Normal Garbage or in a FireEMC SafetyMechanical Page Required Mechanical Characteristics of the Antenna System Specification & OptionsSpecification & Options Specification & Options INTRAC-305 SpecificationDo not Mount by Front Panel Lugs Alone Serial Interfaces VoltageINTRAC-305 Deliberately blank Front Panel Operating the INTRAC-305Operation Menu Structure Operation INTRAC-305Function System SetupNext Field EnterAlphabetical Index of Menus INTRAC-305 Home HomeStandby StandbyGoto Auto Continue New Model NEW ModeMANUAL/STOW Home NEW Mode Menu KEYGoto Position Search OperationGoto Satellite Auto Continue Auto NEW Model When IT is Required to Control the Intrac from Function ConfigurationRemote Terminal Diagnostics Must be Switched OFFHome Function Menu KEY 6 Enter Beacon FrequencyHome Function Menu KEY 6 X2 Enter Config Menu KEY 6 X2 EnterEdit Satellite Table Soft Limits Drive in Manual Mode is not Inhibited bySoft Limits X2 Resolver Setup X2 SetupDiagnostics On Diagnostics on / Diagnostics OFFBeacon Threshold Contrast & Brightness Home Function System Setup EnterSystem Setup Enter Fine Tune sense Home Function System SetupAzimuth true Elevation inv Fine Tune OffsetsStation CO-ORDINATES Date & Time Time Rate Correction AZ & EL Beamwidth Stow Setup Used Select Stow USEFitted Options Models Enter Rapid Model GenerateHome Function Models Enter Models Menu KEY 6 Enter Program TrackHome Function Models Menu KEY 6 Enter Home Function Models Reserve ModelINTRAC-305EDIT IESS-412 Edit Norad Buffer Edit Star Track Edit Satellite Table Intrac IESS-412 Clear ModelsMore Show AlarmsREMOTE/LOCAL Normal Operation Primary Alarms Alarms & ErrorsAlarms & Errors Secondary Alarms Alarms & Errors INTRAC-305Alarm Outputs Recovering from AlarmsErrors INTRAC-305 Alarms & ErrorsPower Failure IESS-412 DataDeliberately blank Technical Description Technical DescriptionTechnical Description INTRAC-305 Modes Technical Description Auto normal operating modeUsing either IESS-412 or Norad data. see Reserve Model 72hrs, the beacon is still not producing a useful signal*Where the satellite’s position is only roughly known search High accuracy of the model the tracking is within 0.05dBManual mode or search mode see below before selecting Enters Standby. The antenna can then be peaked usingManually or in search mode see below. To commence During those scans and phase two of the search isUsing IESS-412 or Norad Data LMO value is given in the range -180to +180. Than two places of decimalsXNDT20 EpochXNDD60 BstarAntenna Motion Limits Axes Position Tracking SignalTechnical Description INTRAC-305 Installation InstallationConnections general Installation INTRAC-305Rear Panel Layout InstallationConnections Block Diagram Intractm 305 Resolvers Connector Connector PIN AllocationsMotor Control Signals to the Motor Drive CabinetRemote Port Stp-Trk Inputs / Alarm outputsCommunication Ports Test Port 1 & 2 RS422 Test Port 1 & 2 RS423Second PC connected to Test Port Data can be monitored during remote operation by using aINTRAC-305 Installation Tracking signal may be provided as a dc voltage from an Tracking Signal InputAppropriate drive command re-instated Emergency Stop switch is releasedOperational Checks Manual OperationAuto Operation Remote ControlFault Finding Fault FindingFault Symptoms Fault Finding INTRAC-305To power up Intrac doesn’t appearTWO Part Retaining PIN Enter Standby Mode System Alarm indicator to illuminate and the Intrac toSwitch consists of two normally closed N.C. contacts Pressing the switch opens both sets of contacts. The switchExample No Antenna DriveFault Finding INTRAC-305 Warranty & Repair Warranty & RepairWarranty Repair ServiceEffective repair technique and issue a repair cost estimate AMT Limited will investigate the fault, determine the mostCustomer either by a Purchase Order or through a Repair Contract