Advantech INTRAC-305 user manual Reserve Model, Home Function Models

Page 52

OPERATION

INTRAC-305

RESERVE MODEL

Current Mode

Tracking

Control State

Local

Beac Freq

11.452000 GHz

Beac Level

-10.05

dB

El

Angle

25.37o

 

Az

Angle

210.50o

 

Pol

Angle

27.4 o

 

>IESS-412

SET

SET

<

NORAD

NOT

 

Press EN to accept selection

Function

Standby

Home

Models

Config

System

Setup

Next

Field

1

2

3

4

5

6

puts the antenna control system into STANDBY mode and skips to the HOME menu

skips to the Home (root) menu

skips to the Models menu

skips to the Config menu

skips to the System Setup menu

moves the highlight box to the next field in the current menu

Path

HOME - FUNCTION - MODELS -

 

MENU KEY 6 (x2) - ENTER

or

From Configuration or System Setup

 

MODELS - MENU KEY 6 (x2) - ENTER

Description

Once the INTRAC-305 has built an orbit model it can track

 

the satellite with no tracking signal for 72hrs. After this time if

 

there is still no signal the INTRAC deems the model to be

 

expired and ceases to track.

 

In such a situation the INTRAC can fall back into Program

 

Track mode using the “Reserve Model”.

 

The “Reserve Model” requires that valid IESS-412 or NORAD

 

data be loaded and that the required reserve model is

 

selected.

 

In this menu the required reserve model, IESS-412 or

 

NORAD is set.

 

Menu Key 6 (Next Field) steps through the two selections.

 

Pressing ENTER accepts the highlighted selection.

Note

The words SET and NOT SET following IESS-412 and

 

NORAD refer to the previous selection. Pressing ENTER will

 

make the highlighted selection SET and the other NOT SET

 

regardless of the current displayed state.

Page 40

INTRAC-305 MANUAL - Issue 3.2

©2011 Advantech Wireless

Image 52
Contents INTRAC-305 PrefacePreface PrefaceManual Sections INTRAC-305 Contents INTRAC-305 SubjectContents InstallationIntroducing the INTRAC-305 Introduction INTRAC-305Introduction Retro FittingIquick Start Guide INTRAC-305 Quick Start Guide Safety Safety INTRAC-305Electrical Do not Place in Normal Garbage or in a FireMechanical SafetyEMC Page Specification & Options Specification & OptionsRequired Mechanical Characteristics of the Antenna System Specification Specification & Options INTRAC-305Do not Mount by Front Panel Lugs Alone Voltage Serial InterfacesINTRAC-305 Deliberately blank Operation Operating the INTRAC-305Front Panel Operation INTRAC-305 Menu StructureSystem Setup FunctionNext Field EnterAlphabetical Index of Menus INTRAC-305 Home HomeStandby StandbyNEW Mode Goto Auto Continue New ModelHome NEW Mode Menu KEY MANUAL/STOWGoto Position Operation SearchGoto Satellite Auto Continue Auto NEW Model Function Configuration When IT is Required to Control the Intrac fromRemote Terminal Diagnostics Must be Switched OFFBeacon Frequency Home Function Menu KEY 6 EnterEdit Satellite Table Config Menu KEY 6 X2 EnterHome Function Menu KEY 6 X2 Enter Soft Limits Drive in Manual Mode is not Inhibited bySoft Limits X2 Setup X2 Resolver SetupDiagnostics on / Diagnostics OFF Diagnostics OnBeacon Threshold System Setup Enter Home Function System Setup EnterContrast & Brightness Home Function System Setup Fine Tune senseFine Tune Offsets Azimuth true Elevation invStation CO-ORDINATES Date & Time Time Rate Correction AZ & EL Beamwidth Stow Setup Select Stow USE UsedFitted Options Home Function Models Enter Rapid Model GenerateModels Enter Home Function Models Menu KEY 6 Enter Program TrackModels Menu KEY 6 Enter Reserve Model Home Function ModelsINTRAC-305EDIT IESS-412 Edit Norad Buffer Edit Star Track Edit Satellite Table Clear Models Intrac IESS-412Show Alarms MoreREMOTE/LOCAL Normal Operation Alarms & Errors Alarms & ErrorsPrimary Alarms Alarms & Errors INTRAC-305 Secondary AlarmsAlarm Outputs Recovering from AlarmsINTRAC-305 Alarms & Errors ErrorsPower Failure IESS-412 DataDeliberately blank Technical Description Technical DescriptionTechnical Description INTRAC-305 Modes Auto normal operating mode Technical Description72hrs, the beacon is still not producing a useful signal* Using either IESS-412 or Norad data. see Reserve ModelWhere the satellite’s position is only roughly known search High accuracy of the model the tracking is within 0.05dBEnters Standby. The antenna can then be peaked using Manual mode or search mode see below before selectingManually or in search mode see below. To commence During those scans and phase two of the search isUsing IESS-412 or Norad Data Than two places of decimals LMO value is given in the range -180to +180.Epoch XNDT20XNDD60 BstarAntenna Motion Limits Tracking Signal Axes PositionTechnical Description INTRAC-305 Installation InstallationInstallation INTRAC-305 Connections generalConnections Block Diagram InstallationRear Panel Layout Connector PIN Allocations Intractm 305 Resolvers ConnectorSignals to the Motor Drive Cabinet Motor ControlCommunication Ports Stp-Trk Inputs / Alarm outputsRemote Port Test Port 1 & 2 RS423 Test Port 1 & 2 RS422Data can be monitored during remote operation by using a Second PC connected to Test PortINTRAC-305 Installation Tracking Signal Input Tracking signal may be provided as a dc voltage from anEmergency Stop switch is released Appropriate drive command re-instatedOperational Checks Manual OperationRemote Control Auto OperationFault Finding Fault FindingFault Finding INTRAC-305 Fault SymptomsTo power up Intrac doesn’t appearTWO Part Retaining PIN System Alarm indicator to illuminate and the Intrac to Enter Standby ModeSwitch consists of two normally closed N.C. contacts Pressing the switch opens both sets of contacts. The switchNo Antenna Drive ExampleFault Finding INTRAC-305 Warranty & Repair Warranty & RepairWarranty Repair ServiceAMT Limited will investigate the fault, determine the most Effective repair technique and issue a repair cost estimateCustomer either by a Purchase Order or through a Repair Contract