Advantech INTRAC-305 user manual NEW Mode, Goto Auto Continue New Model

Page 26

OPERATION

INTRAC-305

NEW MODE

Current Mode

Beac Level

Beac Freq

El Angle

Az Angle

Pol Angle

Local

New Mode

Standby

Home

Manual /Stow

Goto

Auto Continue

Auto

New

Model

1

2

3

4

5

6

puts the antenna control system into STANDBY mode and skips to the HOME menu

skips to the Home (root) menu

moves to the Manual/Stow menu

moves to the 1st ‘Goto’ menu ie Goto Position

resumes tracking using the INTRAC’S current model

clears the INTRAC’S current model and starts learning a new model

Path

Menu key 3 from the “HOME” or “STANDBY” menus.

Description

Displays the current mode and antenna pointing angles on

 

the full screen.

 

This is the entry menu for moving the antenna.

 

Menu key 3 leads to the Manual antenna control and antenna

 

stow menu.

 

Menu key 4 leads to the “Goto” menu for “Goto Position”,

 

“Goto Satellite” and “Search”.

 

Menu key 5 resumes tracking using the current model.

 

(Assuming that there is a valid model).

 

Menu key 6 clears the existing model and starts learning a

 

new model for the satellite at the current pointing.

Page 14

INTRAC-305 MANUAL - Issue 3.2

©2011 Advantech Wireless

Image 26
Contents INTRAC-305 PrefaceManual Sections PrefacePreface INTRAC-305 Contents INTRAC-305 SubjectContents InstallationIntroducing the INTRAC-305 Introduction INTRAC-305Introduction Retro FittingIquick Start Guide INTRAC-305 Quick Start Guide Electrical SafetySafety INTRAC-305 Do not Place in Normal Garbage or in a FireEMC SafetyMechanical Page Required Mechanical Characteristics of the Antenna System Specification & OptionsSpecification & Options Specification Specification & Options INTRAC-305Do not Mount by Front Panel Lugs Alone Voltage Serial InterfacesINTRAC-305 Deliberately blank Front Panel Operating the INTRAC-305Operation Operation INTRAC-305 Menu StructureNext Field System SetupFunction EnterAlphabetical Index of Menus INTRAC-305 Home HomeStandby StandbyNEW Mode Goto Auto Continue New ModelHome NEW Mode Menu KEY MANUAL/STOWGoto Position Operation SearchGoto Satellite Auto Continue Auto NEW Model Remote Terminal Diagnostics Must be Function ConfigurationWhen IT is Required to Control the Intrac from Switched OFFBeacon Frequency Home Function Menu KEY 6 EnterHome Function Menu KEY 6 X2 Enter Config Menu KEY 6 X2 EnterEdit Satellite Table Soft Limits Drive in Manual Mode is not Inhibited bySoft Limits X2 Setup X2 Resolver SetupDiagnostics on / Diagnostics OFF Diagnostics OnBeacon Threshold Contrast & Brightness Home Function System Setup EnterSystem Setup Enter Home Function System Setup Fine Tune senseFine Tune Offsets Azimuth true Elevation invStation CO-ORDINATES Date & Time Time Rate Correction AZ & EL Beamwidth Stow Setup Select Stow USE UsedFitted Options Models Enter Rapid Model GenerateHome Function Models Enter Models Menu KEY 6 Enter Program TrackHome Function Models Menu KEY 6 Enter Reserve Model Home Function ModelsINTRAC-305EDIT IESS-412 Edit Norad Buffer Edit Star Track Edit Satellite Table Clear Models Intrac IESS-412Show Alarms MoreREMOTE/LOCAL Normal Operation Primary Alarms Alarms & ErrorsAlarms & Errors Alarm Outputs Alarms & Errors INTRAC-305Secondary Alarms Recovering from AlarmsPower Failure INTRAC-305 Alarms & ErrorsErrors IESS-412 DataDeliberately blank Technical Description Technical DescriptionTechnical Description INTRAC-305 Modes Auto normal operating mode Technical DescriptionWhere the satellite’s position is only roughly known search 72hrs, the beacon is still not producing a useful signal*Using either IESS-412 or Norad data. see Reserve Model High accuracy of the model the tracking is within 0.05dBManually or in search mode see below. To commence Enters Standby. The antenna can then be peaked usingManual mode or search mode see below before selecting During those scans and phase two of the search isUsing IESS-412 or Norad Data Than two places of decimals LMO value is given in the range -180to +180.XNDD60 EpochXNDT20 BstarAntenna Motion Limits Tracking Signal Axes PositionTechnical Description INTRAC-305 Installation InstallationInstallation INTRAC-305 Connections generalRear Panel Layout InstallationConnections Block Diagram Connector PIN Allocations Intractm 305 Resolvers ConnectorSignals to the Motor Drive Cabinet Motor ControlRemote Port Stp-Trk Inputs / Alarm outputsCommunication Ports Test Port 1 & 2 RS423 Test Port 1 & 2 RS422Data can be monitored during remote operation by using a Second PC connected to Test PortINTRAC-305 Installation Tracking Signal Input Tracking signal may be provided as a dc voltage from anOperational Checks Emergency Stop switch is releasedAppropriate drive command re-instated Manual OperationRemote Control Auto OperationFault Finding Fault FindingTo power up Fault Finding INTRAC-305Fault Symptoms Intrac doesn’t appearTWO Part Retaining PIN Switch consists of two normally closed N.C. contacts System Alarm indicator to illuminate and the Intrac toEnter Standby Mode Pressing the switch opens both sets of contacts. The switchNo Antenna Drive ExampleFault Finding INTRAC-305 Warranty Warranty & RepairWarranty & Repair Repair ServiceCustomer either by a Purchase Order or through a Repair AMT Limited will investigate the fault, determine the mostEffective repair technique and issue a repair cost estimate Contract