INSTALLATION |
|
Installing the
WARNING
POSSIBLE LETHAL POTENTIALS EXIST WITHIN THIS EQUIPMENT
THE COVERS SHOULD NOT BE REMOVED EXCEPT BY QUALIFIED PERSONNEL.
SWITCH OFF POWER AND ISOLATE SUPPLY BEFORE REMOVING COVERS.
IF IT IS NECESSARY TO OPERATE THE EQUIPMENT WITH THE COVERS REMOVED FOR
SERVICING PURPOSES ALL NECESSARY PRECAUTIONS SHOULD BE TAKEN TO
PROTECT AGAINST ELECTRIC SHOCKS
| The |
| system including antenna beamwidth, resolver type and |
| internal or external beacon receiver. |
Note | THE |
| FRONT PANEL LUGS. |
| IT MUST BE SUPPORTED ALONG ITS SIDES |
Connections (general) | Before making connections between the INTRAC Controller |
| and the Motor Cabinet ensure that they are both isolated from |
| the power source. |
| Connect the cables between the Motor Cabinet and the |
| INTRAC. |
| There should be no earth connection between the INTRAC |
| and the Motor Cabinet. |
| All connections between the INTRAC and the Motor Cabinet |
| should be via multi twisted pair cables with individual pairs |
| screened or an overall screen. |
| THE SCREEN(S) SHOULD ONLY BE CONNECTED AT THE |
| INTRAC END. |
Page 66 | ©2011 Advantech Wireless |