Advantech INTRAC-305 user manual Normal Operation

Page 60

OPERATION

INTRAC-305

NORMAL OPERATION

 

Continuing Tracking

With the INTRAC-305 operating normally it will be in Tracking

 

Mode and will require no operator input.

 

Should it become necessary to move the antenna off satellite

 

for some reason, such as to stow it because of wind, all that

 

is required to resume tracking is to select Auto Continue.

 

(after the antenna has been unstowed)

To Track a new Satellite

Set the Beacon Frequency.

 

Set the Polarisation angle if motorised Pol fitted.

 

Point the antenna at the required satellite using Manual

 

control, Goto Position or Goto Satellite.

 

Peak the antenna on the beacon signal using Manual control

 

or Search.

 

When the antenna is peaked on the beacon signal cause the

 

INTRAC to enter Learning Mode by selecting Auto New

 

Model.

 

After 24 hours of learning the INTRAC will automatically enter

 

Tracking Mode.

Note

If Auto Continue is selected instead of Auto New Model and

 

the previous model has not been cleared the antenna will

 

drive back to the previous satellite and continue tracking it.

 

If the beacon signal is lost the INTRAC will enter Predicting

 

Mode. It will then track the satellite by predicting from the

 

model for a period of time depending on how long it has been

 

learning. If Tracking Mode had been achieved before the

 

signal is lost the INTRAC will track in Predicting Mode for up

 

to 72 hours after which time it will deem the model to no

 

longer be accurate enough.

 

When the beacon signal returns, if the INTRAC is still in

 

Predicting Mode, Tracking Mode will be resumed. If the

 

INTRAC has entered Standby, due to the period without

 

signal being too long, Learning Mode will have to be invoked

 

from the front panel.

Page 48

INTRAC-305 MANUAL - Issue 3.2

©2011 Advantech Wireless

Image 60
Contents INTRAC-305 PrefacePreface PrefaceManual Sections INTRAC-305 Contents INTRAC-305 SubjectContents InstallationIntroducing the INTRAC-305 Introduction INTRAC-305Introduction Retro FittingIquick Start Guide INTRAC-305 Quick Start Guide Safety Safety INTRAC-305Electrical Do not Place in Normal Garbage or in a FireSafety MechanicalEMC Page Specification & Options Specification & OptionsRequired Mechanical Characteristics of the Antenna System Specification Specification & Options INTRAC-305Do not Mount by Front Panel Lugs Alone Voltage Serial InterfacesINTRAC-305 Deliberately blank Operating the INTRAC-305 OperationFront Panel Operation INTRAC-305 Menu StructureSystem Setup FunctionNext Field EnterAlphabetical Index of Menus INTRAC-305 Home HomeStandby StandbyNEW Mode Goto Auto Continue New ModelHome NEW Mode Menu KEY MANUAL/STOWGoto Position Operation SearchGoto Satellite Auto Continue Auto NEW Model Function Configuration When IT is Required to Control the Intrac fromRemote Terminal Diagnostics Must be Switched OFFBeacon Frequency Home Function Menu KEY 6 EnterConfig Menu KEY 6 X2 Enter Edit Satellite TableHome Function Menu KEY 6 X2 Enter Drive in Manual Mode is not Inhibited by Soft LimitsSoft Limits X2 Setup X2 Resolver SetupDiagnostics on / Diagnostics OFF Diagnostics OnBeacon Threshold Home Function System Setup Enter System Setup EnterContrast & Brightness Home Function System Setup Fine Tune senseFine Tune Offsets Azimuth true Elevation invStation CO-ORDINATES Date & Time Time Rate Correction AZ & EL Beamwidth Stow Setup Select Stow USE UsedFitted Options Rapid Model Generate Home Function Models EnterModels Enter Program Track Home Function Models Menu KEY 6 EnterModels Menu KEY 6 Enter Reserve Model Home Function ModelsINTRAC-305EDIT IESS-412 Edit Norad Buffer Edit Star Track Edit Satellite Table Clear Models Intrac IESS-412Show Alarms MoreREMOTE/LOCAL Normal Operation Alarms & Errors Alarms & ErrorsPrimary Alarms Alarms & Errors INTRAC-305 Secondary AlarmsAlarm Outputs Recovering from AlarmsINTRAC-305 Alarms & Errors ErrorsPower Failure IESS-412 DataDeliberately blank Technical Description Technical DescriptionTechnical Description INTRAC-305 Modes Auto normal operating mode Technical Description72hrs, the beacon is still not producing a useful signal* Using either IESS-412 or Norad data. see Reserve ModelWhere the satellite’s position is only roughly known search High accuracy of the model the tracking is within 0.05dBEnters Standby. The antenna can then be peaked using Manual mode or search mode see below before selectingManually or in search mode see below. To commence During those scans and phase two of the search isUsing IESS-412 or Norad Data Than two places of decimals LMO value is given in the range -180to +180.Epoch XNDT20XNDD60 BstarAntenna Motion Limits Tracking Signal Axes PositionTechnical Description INTRAC-305 Installation InstallationInstallation INTRAC-305 Connections generalInstallation Connections Block DiagramRear Panel Layout Connector PIN Allocations Intractm 305 Resolvers ConnectorSignals to the Motor Drive Cabinet Motor ControlStp-Trk Inputs / Alarm outputs Communication PortsRemote Port Test Port 1 & 2 RS423 Test Port 1 & 2 RS422Data can be monitored during remote operation by using a Second PC connected to Test PortINTRAC-305 Installation Tracking Signal Input Tracking signal may be provided as a dc voltage from anEmergency Stop switch is released Appropriate drive command re-instatedOperational Checks Manual OperationRemote Control Auto OperationFault Finding Fault FindingFault Finding INTRAC-305 Fault SymptomsTo power up Intrac doesn’t appearTWO Part Retaining PIN System Alarm indicator to illuminate and the Intrac to Enter Standby ModeSwitch consists of two normally closed N.C. contacts Pressing the switch opens both sets of contacts. The switchNo Antenna Drive ExampleFault Finding INTRAC-305 Warranty & Repair Warranty & RepairWarranty Repair ServiceAMT Limited will investigate the fault, determine the most Effective repair technique and issue a repair cost estimateCustomer either by a Purchase Order or through a Repair Contract