Advantech INTRAC-305 user manual Operation, Fitted Options

Page 49

INTRAC-305

FITTED OPTIONS

3

OPERATION

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Function

 

 

Current Mode

Tracking

 

 

Standby

 

 

Control State

Local

 

 

 

 

Beac Freq

 

11.452000 GHz

 

 

 

 

Beac Level

-10.05

dB

 

 

 

 

El

Angle

25.37

 

 

Home

 

 

Az

Angle

210.50

 

 

 

 

Pol

Angle

27.4

 

 

 

 

 

 

Beacon

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Receiver: Fitted

 

 

 

 

 

Beac pol select: Not Fitted

 

Fitted/

 

 

Polarization

: Fitted

 

 

 

 

Mount

Az/El : Fitted

 

 

Not

 

 

Type HrAng/Dcl: Not Fitted

 

 

 

 

 

Recall

 

 

Resolver x2

: Fitted

 

 

 

 

 

 

Existing

 

 

Type

x1

: Not Fitted

 

Settings

 

 

Extended Az

: Not Fitted

 

 

 

 

 

Next

 

 

Geared Pol

: Not Fitted

 

 

 

SimAx Drive

: Fitted

 

 

Field

 

 

Inv Beacon Lock: Not Fitted

 

 

 

 

Press EN to accept all fields

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

2

3

4

5

6

puts the antenna control system into STANDBY mode and skips to the HOME menu

skips to the Home (root) menu

(not used)

toggles the highlighted parameter between Fitted/Not Fitted

resets the menu to display the currently stored values

moves the highlight box to the next field in the current menu

Path

HOME - FUNCTION - SYSTEM SETUP -

 

MENU KEY 6 (x6) - ENTER

or

From Models or Configuration

 

SYSTEM SETUP - MENU KEY 6 (x6) - ENTER

Description

Various options such as polarisation drive and simultaneous

 

axis drive are available on the INTRAC-305. Their use has to

 

be programmed into the INTRAC in order for them to be

 

usable. That programming is carried out in this menu.

 

The various options are shown on this screen.

 

Menu Key 6 (Next Field) steps the highlighted edit line

 

through the options.

 

Menu Key 4 (Fitted/Not) toggles the option between fitted and

 

not fitted.

 

Menu Key 5 (Recall Existing Settings) resets the options to

 

the state they were in when this menu was entered.

 

Pressing ENTER accepts the displayed settings.

Note

Beacon Pol Select, Extended Az, Geared Pol, and Inv

 

Beacon Lock should be set to “Not Fitted”.

 

SimAx Drive should be set to “Fitted”.

 

Normally, when replacing an APC300, the correct resolver

 

type will be x2.

© 2011 Advantech Wireless

INTRAC-305 MANUAL - Issue 3.2

Page 37

Image 49
Contents Preface INTRAC-305Preface PrefaceManual Sections INTRAC-305 Subject Contents INTRAC-305Installation ContentsIntroduction INTRAC-305 Introducing the INTRAC-305Retro Fitting IntroductionIquick Start Guide INTRAC-305 Quick Start Guide Safety INTRAC-305 SafetyElectrical Do not Place in Normal Garbage or in a FireMechanical SafetyEMC Page Specification & Options Specification & OptionsRequired Mechanical Characteristics of the Antenna System Specification & Options INTRAC-305 SpecificationDo not Mount by Front Panel Lugs Alone Serial Interfaces VoltageINTRAC-305 Deliberately blank Operation Operating the INTRAC-305Front Panel Menu Structure Operation INTRAC-305Function System SetupNext Field EnterAlphabetical Index of Menus INTRAC-305 Home HomeStandby StandbyGoto Auto Continue New Model NEW ModeMANUAL/STOW Home NEW Mode Menu KEYGoto Position Search OperationGoto Satellite Auto Continue Auto NEW Model When IT is Required to Control the Intrac from Function ConfigurationRemote Terminal Diagnostics Must be Switched OFFHome Function Menu KEY 6 Enter Beacon FrequencyEdit Satellite Table Config Menu KEY 6 X2 EnterHome Function Menu KEY 6 X2 Enter Soft Limits Drive in Manual Mode is not Inhibited bySoft Limits X2 Resolver Setup X2 SetupDiagnostics On Diagnostics on / Diagnostics OFFBeacon Threshold System Setup Enter Home Function System Setup EnterContrast & Brightness Fine Tune sense Home Function System SetupAzimuth true Elevation inv Fine Tune OffsetsStation CO-ORDINATES Date & Time Time Rate Correction AZ & EL Beamwidth Stow Setup Used Select Stow USEFitted Options Home Function Models Enter Rapid Model GenerateModels Enter Home Function Models Menu KEY 6 Enter Program TrackModels Menu KEY 6 Enter Home Function Models Reserve ModelINTRAC-305EDIT IESS-412 Edit Norad Buffer Edit Star Track Edit Satellite Table Intrac IESS-412 Clear ModelsMore Show AlarmsREMOTE/LOCAL Normal Operation Alarms & Errors Alarms & ErrorsPrimary Alarms Secondary Alarms Alarms & Errors INTRAC-305Alarm Outputs Recovering from AlarmsErrors INTRAC-305 Alarms & ErrorsPower Failure IESS-412 DataDeliberately blank Technical Description Technical DescriptionTechnical Description INTRAC-305 Modes Technical Description Auto normal operating modeUsing either IESS-412 or Norad data. see Reserve Model 72hrs, the beacon is still not producing a useful signal*Where the satellite’s position is only roughly known search High accuracy of the model the tracking is within 0.05dBManual mode or search mode see below before selecting Enters Standby. The antenna can then be peaked usingManually or in search mode see below. To commence During those scans and phase two of the search isUsing IESS-412 or Norad Data LMO value is given in the range -180to +180. Than two places of decimalsXNDT20 EpochXNDD60 BstarAntenna Motion Limits Axes Position Tracking SignalTechnical Description INTRAC-305 Installation InstallationConnections general Installation INTRAC-305Connections Block Diagram InstallationRear Panel Layout Intractm 305 Resolvers Connector Connector PIN AllocationsMotor Control Signals to the Motor Drive CabinetCommunication Ports Stp-Trk Inputs / Alarm outputsRemote Port Test Port 1 & 2 RS422 Test Port 1 & 2 RS423Second PC connected to Test Port Data can be monitored during remote operation by using aINTRAC-305 Installation Tracking signal may be provided as a dc voltage from an Tracking Signal InputAppropriate drive command re-instated Emergency Stop switch is releasedOperational Checks Manual OperationAuto Operation Remote ControlFault Finding Fault FindingFault Symptoms Fault Finding INTRAC-305To power up Intrac doesn’t appearTWO Part Retaining PIN Enter Standby Mode System Alarm indicator to illuminate and the Intrac toSwitch consists of two normally closed N.C. contacts Pressing the switch opens both sets of contacts. The switchExample No Antenna DriveFault Finding INTRAC-305 Warranty & Repair Warranty & RepairWarranty Repair ServiceEffective repair technique and issue a repair cost estimate AMT Limited will investigate the fault, determine the mostCustomer either by a Purchase Order or through a Repair Contract