Advantech INTRAC-305 user manual No Antenna Drive, Example

Page 93

7

INTRAC-305

FAULT FINDING

If all the angles are changing the fault is on the Interface PCB.

wrong angle displayed If the displayed angle changes to be near 0° or 90° it is probable that one of the two return signal circuits from the resolver is broken or the resolver itself is faulty.

If the displayed angle changes to any angle other than near 0° or 90° the fault is on the Interface PCB.

angle doesn’t change If the displayed angle doesn’t change when the antenna is

when antenna is moved being driven first ensure that the antenna is actually moving in the relevant plane. Select Manual Mode and drive the antenna in the appropriate direction and either check that the beacon level changes or actually look at the antenna.

If the antenna moves but the displayed angle does not change the problem is the connection of the resolver to the antenna.

No Antenna Drive

Check that the LEDs in the Manual Control keys illuminate

 

 

 

when antenna drive is commanded. If not the fault is on the

 

 

 

Interface PCB.

 

 

 

 

 

 

 

 

 

 

 

 

The Motor Controls connector (50-way D-type) on INTRAC

 

 

 

rear panel outputs +12v and ground to for each drive signal.

 

 

 

The +12v and ground levels are switched to the approriate

 

 

 

pins of the connector by relays. One relay switches +12v for

 

 

 

all Az drive commands, another does so for all El drive

 

 

 

 

commands and a third for Pol drive. The ground level is

 

 

 

switched by changeover relays, one does Az West or East,

 

 

 

another Az Fast or Slow, another El Down or Up, another El

 

 

 

Fast or Slow and another for Pol CCW or CW.

 

 

 

 

 

 

The table below indicates across which two pins of the 50

 

 

 

way connector there should be 12v for each drive condition.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Direction

 

Az

Az

 

Az

Az

El

 

El

El

El

 

Pol

Pol

 

& Speed

 

East

West

 

Fast

Slow

Down

 

Up

Fast

Slow

 

CCw

Cw

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

+12 volts

 

18

19

 

20

21

22

 

23

24

25

 

26

27

 

Ground

 

1

2

 

3

4

5

 

6

7

8

 

9

10

 

 

 

 

 

 

 

 

 

 

 

 

 

 

example

Elevation Up Fast -

there should be 12v across pins 23 & 6

 

 

 

(El Up) and across 24 & 7 (El Fast).

 

 

 

 

 

 

If the drive signals from the INTRAC are correct the fault lies with the Motor Drive Cabinet, the antenna drive motors or the intervening wiring.

© Advantech Wireless

INTRAC-305 MANUAL - Issue 3.2

Page 81

Image 93
Contents Preface INTRAC-305Preface PrefaceManual Sections INTRAC-305 Subject Contents INTRAC-305Installation ContentsIntroduction INTRAC-305 Introducing the INTRAC-305Retro Fitting IntroductionIquick Start Guide INTRAC-305 Quick Start Guide Safety INTRAC-305 SafetyElectrical Do not Place in Normal Garbage or in a FireSafety MechanicalEMC Page Specification & Options Specification & OptionsRequired Mechanical Characteristics of the Antenna System Specification & Options INTRAC-305 SpecificationDo not Mount by Front Panel Lugs Alone Serial Interfaces VoltageINTRAC-305 Deliberately blank Operating the INTRAC-305 OperationFront Panel Menu Structure Operation INTRAC-305Function System SetupNext Field EnterAlphabetical Index of Menus INTRAC-305 Home HomeStandby StandbyGoto Auto Continue New Model NEW ModeMANUAL/STOW Home NEW Mode Menu KEYGoto Position Search OperationGoto Satellite Auto Continue Auto NEW Model When IT is Required to Control the Intrac from Function ConfigurationRemote Terminal Diagnostics Must be Switched OFFHome Function Menu KEY 6 Enter Beacon FrequencyConfig Menu KEY 6 X2 Enter Edit Satellite TableHome Function Menu KEY 6 X2 Enter Drive in Manual Mode is not Inhibited by Soft LimitsSoft Limits X2 Resolver Setup X2 SetupDiagnostics On Diagnostics on / Diagnostics OFFBeacon Threshold Home Function System Setup Enter System Setup EnterContrast & Brightness Fine Tune sense Home Function System SetupAzimuth true Elevation inv Fine Tune OffsetsStation CO-ORDINATES Date & Time Time Rate Correction AZ & EL Beamwidth Stow Setup Used Select Stow USEFitted Options Rapid Model Generate Home Function Models EnterModels Enter Program Track Home Function Models Menu KEY 6 EnterModels Menu KEY 6 Enter Home Function Models Reserve ModelINTRAC-305EDIT IESS-412 Edit Norad Buffer Edit Star Track Edit Satellite Table Intrac IESS-412 Clear ModelsMore Show AlarmsREMOTE/LOCAL Normal Operation Alarms & Errors Alarms & ErrorsPrimary Alarms Secondary Alarms Alarms & Errors INTRAC-305Alarm Outputs Recovering from AlarmsErrors INTRAC-305 Alarms & ErrorsPower Failure IESS-412 DataDeliberately blank Technical Description Technical DescriptionTechnical Description INTRAC-305 Modes Technical Description Auto normal operating modeUsing either IESS-412 or Norad data. see Reserve Model 72hrs, the beacon is still not producing a useful signal*Where the satellite’s position is only roughly known search High accuracy of the model the tracking is within 0.05dBManual mode or search mode see below before selecting Enters Standby. The antenna can then be peaked usingManually or in search mode see below. To commence During those scans and phase two of the search isUsing IESS-412 or Norad Data LMO value is given in the range -180to +180. Than two places of decimalsXNDT20 EpochXNDD60 BstarAntenna Motion Limits Axes Position Tracking SignalTechnical Description INTRAC-305 Installation InstallationConnections general Installation INTRAC-305Installation Connections Block DiagramRear Panel Layout Intractm 305 Resolvers Connector Connector PIN AllocationsMotor Control Signals to the Motor Drive CabinetStp-Trk Inputs / Alarm outputs Communication PortsRemote Port Test Port 1 & 2 RS422 Test Port 1 & 2 RS423Second PC connected to Test Port Data can be monitored during remote operation by using aINTRAC-305 Installation Tracking signal may be provided as a dc voltage from an Tracking Signal InputAppropriate drive command re-instated Emergency Stop switch is releasedOperational Checks Manual OperationAuto Operation Remote ControlFault Finding Fault FindingFault Symptoms Fault Finding INTRAC-305To power up Intrac doesn’t appearTWO Part Retaining PIN Enter Standby Mode System Alarm indicator to illuminate and the Intrac toSwitch consists of two normally closed N.C. contacts Pressing the switch opens both sets of contacts. The switchExample No Antenna DriveFault Finding INTRAC-305 Warranty & Repair Warranty & RepairWarranty Repair ServiceEffective repair technique and issue a repair cost estimate AMT Limited will investigate the fault, determine the mostCustomer either by a Purchase Order or through a Repair Contract