Advantech INTRAC-305 user manual Operation, Edit Star Track

Page 55

3

INTRAC-305

OPERATION

EDIT STAR TRACK

Current Mode

Tracking

 

Control State

Local

 

Beac Freq

11.452000 GHz

Beac Level

-10.05

 

dB

El

Angle

25.37o

 

Az

Angle

210.50o

 

Pol

Angle

27.4

o

 

Year

00

Hour

13

Month

1

Minute

21

Day

1

Second

35

Star

Az

123.12

Star

El

57.32

Press EN to accept selection

Function

Standby

Home

Models

Config

System

Setup

Next

Field

1

2

3

4

5

6

puts the antenna control system into STANDBY mode and skips to the HOME menu

skips to the Home (root) menu

skips to the Models menu

skips to the Config menu

skips to the System Setup menu

moves the highlight box to the next field in the current menu

Path

HOME - FUNCTION - MODELS -

 

MENU KEY 6 (x5) - ENTER

or

From Configure or System Setup

 

MODELS - MENU KEY 6 (x5) - ENTER

Description

The Star Track Model keeps the antenna pointed at a specific

 

star by compensating for the rotation of the earth.

 

It requires the co-ordinates of the star to be input together

 

with the date and time of those co-ordinates.

 

The model is then built using above data and the Station Co-

 

ordinates. (see Station Co-ordinates menu on page 33)

 

Menu Key 6 (Next Field) steps the edit box through the eight

 

data fields. The data is entered using the Numeric Keypad.

 

Pressing ENTER accepts the displayed data and enters Star

 

Track mode.

Note

This facility is used for engineering purposes.

© 2011 Advantech Wireless

INTRAC-305 MANUAL - Issue 3.2

Page 43

Image 55
Contents Preface INTRAC-305Preface PrefaceManual Sections INTRAC-305 Subject Contents INTRAC-305Installation ContentsIntroduction INTRAC-305 Introducing the INTRAC-305Retro Fitting IntroductionIquick Start Guide INTRAC-305 Quick Start Guide Do not Place in Normal Garbage or in a Fire SafetySafety INTRAC-305 ElectricalMechanical SafetyEMC Page Specification & Options Specification & OptionsRequired Mechanical Characteristics of the Antenna System Specification & Options INTRAC-305 SpecificationDo not Mount by Front Panel Lugs Alone Serial Interfaces VoltageINTRAC-305 Deliberately blank Operation Operating the INTRAC-305Front Panel Menu Structure Operation INTRAC-305Enter System SetupFunction Next FieldAlphabetical Index of Menus INTRAC-305 Home HomeStandby StandbyGoto Auto Continue New Model NEW ModeMANUAL/STOW Home NEW Mode Menu KEYGoto Position Search OperationGoto Satellite Auto Continue Auto NEW Model Switched OFF Function ConfigurationWhen IT is Required to Control the Intrac from Remote Terminal Diagnostics Must beHome Function Menu KEY 6 Enter Beacon FrequencyEdit Satellite Table Config Menu KEY 6 X2 EnterHome Function Menu KEY 6 X2 Enter Soft Limits Drive in Manual Mode is not Inhibited bySoft Limits X2 Resolver Setup X2 SetupDiagnostics On Diagnostics on / Diagnostics OFFBeacon Threshold System Setup Enter Home Function System Setup EnterContrast & Brightness Fine Tune sense Home Function System SetupAzimuth true Elevation inv Fine Tune OffsetsStation CO-ORDINATES Date & Time Time Rate Correction AZ & EL Beamwidth Stow Setup Used Select Stow USEFitted Options Home Function Models Enter Rapid Model GenerateModels Enter Home Function Models Menu KEY 6 Enter Program TrackModels Menu KEY 6 Enter Home Function Models Reserve ModelINTRAC-305EDIT IESS-412 Edit Norad Buffer Edit Star Track Edit Satellite Table Intrac IESS-412 Clear ModelsMore Show AlarmsREMOTE/LOCAL Normal Operation Alarms & Errors Alarms & ErrorsPrimary Alarms Recovering from Alarms Alarms & Errors INTRAC-305Secondary Alarms Alarm OutputsIESS-412 Data INTRAC-305 Alarms & ErrorsErrors Power FailureDeliberately blank Technical Description Technical DescriptionTechnical Description INTRAC-305 Modes Technical Description Auto normal operating modeHigh accuracy of the model the tracking is within 0.05dB 72hrs, the beacon is still not producing a useful signal*Using either IESS-412 or Norad data. see Reserve Model Where the satellite’s position is only roughly known searchDuring those scans and phase two of the search is Enters Standby. The antenna can then be peaked usingManual mode or search mode see below before selecting Manually or in search mode see below. To commenceUsing IESS-412 or Norad Data LMO value is given in the range -180to +180. Than two places of decimalsBstar EpochXNDT20 XNDD60Antenna Motion Limits Axes Position Tracking SignalTechnical Description INTRAC-305 Installation InstallationConnections general Installation INTRAC-305Connections Block Diagram InstallationRear Panel Layout Intractm 305 Resolvers Connector Connector PIN AllocationsMotor Control Signals to the Motor Drive CabinetCommunication Ports Stp-Trk Inputs / Alarm outputsRemote Port Test Port 1 & 2 RS422 Test Port 1 & 2 RS423Second PC connected to Test Port Data can be monitored during remote operation by using aINTRAC-305 Installation Tracking signal may be provided as a dc voltage from an Tracking Signal InputManual Operation Emergency Stop switch is releasedAppropriate drive command re-instated Operational ChecksAuto Operation Remote ControlFault Finding Fault FindingIntrac doesn’t appear Fault Finding INTRAC-305Fault Symptoms To power upTWO Part Retaining PIN Pressing the switch opens both sets of contacts. The switch System Alarm indicator to illuminate and the Intrac toEnter Standby Mode Switch consists of two normally closed N.C. contactsExample No Antenna DriveFault Finding INTRAC-305 Repair Service Warranty & RepairWarranty & Repair WarrantyContract AMT Limited will investigate the fault, determine the mostEffective repair technique and issue a repair cost estimate Customer either by a Purchase Order or through a Repair