OPERATION |
|
DIAGNOSTICS ON / DIAGNOSTICS OFF
Current Mode | Tracking |
| |
Control State | Local |
| |
Beac Freq | 11.452000 GHz | ||
Beac Level |
| ||
El | Angle | 25.37 |
|
Az | Angle | 210.50 |
|
Pol | Angle | 27.4 |
|
| Beacon Frequncy |
| |
| Edit Satellite Table |
| |
| Soft Limits |
| |
| Extended Azimuth Setup | ||
| > Diagnostics On | < | |
| Diagnostics Off |
| |
| Beacon Threshold |
| |
Press EN to accept selection |
Function
Standby
Home
Models
Test
Diags
System
Setup
Next
Field
1 |
2 |
3 |
4 |
5 |
6 |
puts the antenna control system into STANDBY mode and skips to the HOME menu
skips to the Home (root) menu
skips to the Models menu
selects whether ‘Angles’ or ‘Diagnostics’ appear on Test Port 1
skips to the System Setup menu
moves the highlight box to the next field in the current menu
Path | HOME - FUNCTION - MENU KEY 6 (x5 for ON) |
| (x6 for OFF) - ENTER |
or | From Models or System Setup |
| CONFIG - MENU KEY 6 (x5 or 6) - ENTER |
Description | Diagnostics On & Off are used to route the INTRAC |
| diagnostic data to the Remote Control port. |
| Use Menu Key 6 to step the highlight bar to the ON or OFF |
| line and press ENTER to set. |
Note | This facility enables one PC to be used as both the remote |
| control terminal and the diagnostics receiving terminal. |
| However it cannot do both at the same time. |
| WHEN IT IS REQUIRED TO CONTROL THE INTRAC FROM |
| THE REMOTE TERMINAL DIAGNOSTICS MUST BE |
| SWITCHED OFF. |
Page 26 | ©2011 Advantech Wireless |