Advantech INTRAC-305 user manual Warranty & Repair, Repair Service

Page 95

8

INTRAC-305

WARRANTY & REPAIR

8.WARRANTY & REPAIR

WARRANTY

Advantech AMT Limited warrants the INTRAC-305 Antenna

 

Control Unit, the (optional) IBR-L integral L-band beacon

 

receiver and other associated products designed,

 

manufactured and supplied by Advantech AMT Limited for a

 

period of 365 days from the date of delivery.

 

The liability of Advantech AMT Limited under this warranty

 

shall be limited to repair or replacement of defective units or

 

parts thereof, at Advantech’s option, which are returned,

 

carriage and insurance paid, to Advantech AMT Limited, 39

 

Edison Road, St.Ives, Cambridgeshire, PE27 3LF, England.

 

The returned unit(s) must be accompanied by a document

 

declaring that the equipment is returned for repair under

 

warranty and describing clearly and fully the reason for the

 

return of the unit.

 

Subject to the unit being eligible for warranty repair

 

Advantech AMT Limited will effect the repair and return the

 

unit by pre-paid shipment to the originating location. Subject

 

to the shipment charges being the same as, or less than, that

 

to the original location the unit may be shipped to some other

 

location as the customer may specify.

 

Under no circumstances shall Advantech AMT Limited be

 

liable for any consequential or incidental costs or damage.

Exclusions

This warranty does not apply to any equipment which has

 

been damaged through abuse, accident (such as lightning

 

strike), negligence or failure to comply with Advantech AMT

 

Ltd instructions for storage, installation and use as contained

 

in the equipment manual(s).

 

Except as specifically provided above Advantech AMT

 

Limited makes no warranties, expressed or implied, as to the

 

merchantability or fitness for a particular purpose.

REPAIR SERVICE

Advantech AMT Limited will provide a repair service for all

 

equipment manufactured by Advantech AMT Limited for a

 

period of ten (10) years.

Returning equipment for repair

Prior to the return of any equipment for repair, whether under

 

warranty or by payment, Advantech AMT Limited must be

 

contacted. The purpose of this contact is to discuss the

 

problem and confirm that equipment needs to be returned.

 

Also to agree the most effective solution to the problem and

 

to discuss the method of return in order to avoid unnecessary

 

duties and ensure that the packing is adequate to protect the

 

equipment during shipment.

 

The cost of returning the equipment to Advantech AMT

 

Limited will be paid by the customer.

Repairs not under warranty

Repairs to equipment not under warranty will be paid for by

 

the customer. On receipt of the defective unit Advantech

© Advantech Wireless

INTRAC-305 MANUAL - Issue 3.2

Page 83

Image 95
Contents Preface INTRAC-305Manual Sections PrefacePreface INTRAC-305 Subject Contents INTRAC-305Installation ContentsIntroduction INTRAC-305 Introducing the INTRAC-305Retro Fitting IntroductionIquick Start Guide INTRAC-305 Quick Start Guide Do not Place in Normal Garbage or in a Fire SafetySafety INTRAC-305 ElectricalEMC SafetyMechanical Page Required Mechanical Characteristics of the Antenna System Specification & OptionsSpecification & Options Specification & Options INTRAC-305 SpecificationDo not Mount by Front Panel Lugs Alone Serial Interfaces VoltageINTRAC-305 Deliberately blank Front Panel Operating the INTRAC-305Operation Menu Structure Operation INTRAC-305Enter System SetupFunction Next FieldAlphabetical Index of Menus INTRAC-305 Home HomeStandby StandbyGoto Auto Continue New Model NEW ModeMANUAL/STOW Home NEW Mode Menu KEYGoto Position Search OperationGoto Satellite Auto Continue Auto NEW Model Switched OFF Function ConfigurationWhen IT is Required to Control the Intrac from Remote Terminal Diagnostics Must beHome Function Menu KEY 6 Enter Beacon FrequencyHome Function Menu KEY 6 X2 Enter Config Menu KEY 6 X2 EnterEdit Satellite Table Soft Limits Drive in Manual Mode is not Inhibited bySoft Limits X2 Resolver Setup X2 SetupDiagnostics On Diagnostics on / Diagnostics OFFBeacon Threshold Contrast & Brightness Home Function System Setup EnterSystem Setup Enter Fine Tune sense Home Function System SetupAzimuth true Elevation inv Fine Tune OffsetsStation CO-ORDINATES Date & Time Time Rate Correction AZ & EL Beamwidth Stow Setup Used Select Stow USEFitted Options Models Enter Rapid Model GenerateHome Function Models Enter Models Menu KEY 6 Enter Program TrackHome Function Models Menu KEY 6 Enter Home Function Models Reserve ModelINTRAC-305EDIT IESS-412 Edit Norad Buffer Edit Star Track Edit Satellite Table Intrac IESS-412 Clear ModelsMore Show AlarmsREMOTE/LOCAL Normal Operation Primary Alarms Alarms & ErrorsAlarms & Errors Recovering from Alarms Alarms & Errors INTRAC-305Secondary Alarms Alarm OutputsIESS-412 Data INTRAC-305 Alarms & ErrorsErrors Power FailureDeliberately blank Technical Description Technical DescriptionTechnical Description INTRAC-305 Modes Technical Description Auto normal operating modeHigh accuracy of the model the tracking is within 0.05dB 72hrs, the beacon is still not producing a useful signal*Using either IESS-412 or Norad data. see Reserve Model Where the satellite’s position is only roughly known searchDuring those scans and phase two of the search is Enters Standby. The antenna can then be peaked usingManual mode or search mode see below before selecting Manually or in search mode see below. To commenceUsing IESS-412 or Norad Data LMO value is given in the range -180to +180. Than two places of decimalsBstar EpochXNDT20 XNDD60Antenna Motion Limits Axes Position Tracking SignalTechnical Description INTRAC-305 Installation InstallationConnections general Installation INTRAC-305Rear Panel Layout InstallationConnections Block Diagram Intractm 305 Resolvers Connector Connector PIN AllocationsMotor Control Signals to the Motor Drive CabinetRemote Port Stp-Trk Inputs / Alarm outputsCommunication Ports Test Port 1 & 2 RS422 Test Port 1 & 2 RS423Second PC connected to Test Port Data can be monitored during remote operation by using aINTRAC-305 Installation Tracking signal may be provided as a dc voltage from an Tracking Signal InputManual Operation Emergency Stop switch is releasedAppropriate drive command re-instated Operational ChecksAuto Operation Remote ControlFault Finding Fault FindingIntrac doesn’t appear Fault Finding INTRAC-305Fault Symptoms To power upTWO Part Retaining PIN Pressing the switch opens both sets of contacts. The switch System Alarm indicator to illuminate and the Intrac toEnter Standby Mode Switch consists of two normally closed N.C. contactsExample No Antenna DriveFault Finding INTRAC-305 Repair Service Warranty & RepairWarranty & Repair WarrantyContract AMT Limited will investigate the fault, determine the mostEffective repair technique and issue a repair cost estimate Customer either by a Purchase Order or through a Repair