Advantech INTRAC-305 Function Configuration, Home Menu KEY, Remote Terminal Diagnostics Must be

Page 33

INTRAC-305

FUNCTION (Configuration)

3

OPERATION

 

Current Mode

Tracking

Function

 

 

 

 

 

 

Standby

 

 

Control State

Local

 

 

Beac Freq

11.452000 GHz

 

 

 

Beac Level

-10.05 dB

 

 

 

 

 

El

Angle

25.37

 

 

Home

 

 

Az

Angle

210.50

 

 

 

 

Pol

Angle

27.4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Models

 

 

 

 

 

 

 

 

 

 

 

 

 

 

> Beacon Pol not avail <

Test

 

 

 

 

Port-1

 

 

 

 

Beacon Frequency

Diags

 

 

 

 

Edit Satellite Table

 

 

 

 

 

System

 

 

 

 

Soft Limits

 

 

 

 

x2 Setup

 

 

 

Setup

 

 

 

 

Diagnostics On

 

 

 

 

 

Next

 

 

 

 

Diagnostics Off

 

 

 

 

Beacon Threshold

Field

 

 

Press EN to accept selection

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

2

3

4

5

6

puts the antenna control system into STANDBY mode and skips to the HOME menu

skips to the Home (root) menu

skips to the Models menu

controls whether ‘Angles’ or ‘Diagnostics’ appear on Test Port 1

skips to the System Setup menu

moves the highlight box to the next field in the current menu

Path

HOME - MENU KEY 4

Note

There are three separate menus under the FUNCTION

 

heading. Pressing Menu Key 4 (FUNCTION) on the “Home“

 

menu leads to the CONFIGURATION menu from which the

 

MODELS menu and the SYSTEM SETUP menu are reached

 

via Menu Keys 3 & 5 respectively.

 

This Configuration menu can also be reached by Menu Keys

 

from the MODELS & SYSTEM SETUP menus

Description

The Configuration menu contains seven sub menus plus

 

Diagnostics On & Off.

 

The sub menus are described on the following pages.

 

The Diagnostics On & Off keys are used to route the INTRAC

 

diagnostic data to the Remote Control port. This facility

 

enables one PC to be used as both the remote control

 

terminal and the diagnostics receiving terminal. However it

 

cannot do both at the same time.

 

WHEN IT IS REQUIRED TO CONTROL THE INTRAC FROM

 

THE REMOTE TERMINAL DIAGNOSTICS MUST BE

 

SWITCHED OFF.

Menu Key 4

Test Port - 1 Diags (Angles)

 

The data available at Test Port - 1 is either INTRAC

 

diagnostic data (the same diagnostic data as mentioned

 

above) or angles data. Selection between these two is by

 

Menu Key 4 whose label toggles between “Diags” & “Angles”

© 2011 Advantech Wireless

INTRAC-305 MANUAL - Issue 3.2

Page 21

Image 33
Contents Preface INTRAC-305Preface PrefaceManual Sections INTRAC-305 Subject Contents INTRAC-305Installation ContentsIntroduction INTRAC-305 Introducing the INTRAC-305Retro Fitting IntroductionIquick Start Guide INTRAC-305 Quick Start Guide Safety INTRAC-305 SafetyElectrical Do not Place in Normal Garbage or in a FireSafety MechanicalEMC Page Specification & Options Specification & OptionsRequired Mechanical Characteristics of the Antenna System Specification & Options INTRAC-305 SpecificationDo not Mount by Front Panel Lugs Alone Serial Interfaces VoltageINTRAC-305 Deliberately blank Operating the INTRAC-305 OperationFront Panel Menu Structure Operation INTRAC-305Function System SetupNext Field EnterAlphabetical Index of Menus INTRAC-305 Home HomeStandby StandbyGoto Auto Continue New Model NEW ModeMANUAL/STOW Home NEW Mode Menu KEYGoto Position Search OperationGoto Satellite Auto Continue Auto NEW Model When IT is Required to Control the Intrac from Function ConfigurationRemote Terminal Diagnostics Must be Switched OFFHome Function Menu KEY 6 Enter Beacon FrequencyConfig Menu KEY 6 X2 Enter Edit Satellite TableHome Function Menu KEY 6 X2 Enter Drive in Manual Mode is not Inhibited by Soft LimitsSoft Limits X2 Resolver Setup X2 SetupDiagnostics On Diagnostics on / Diagnostics OFFBeacon Threshold Home Function System Setup Enter System Setup EnterContrast & Brightness Fine Tune sense Home Function System SetupAzimuth true Elevation inv Fine Tune OffsetsStation CO-ORDINATES Date & Time Time Rate Correction AZ & EL Beamwidth Stow Setup Used Select Stow USEFitted Options Rapid Model Generate Home Function Models EnterModels Enter Program Track Home Function Models Menu KEY 6 EnterModels Menu KEY 6 Enter Home Function Models Reserve ModelINTRAC-305EDIT IESS-412 Edit Norad Buffer Edit Star Track Edit Satellite Table Intrac IESS-412 Clear ModelsMore Show AlarmsREMOTE/LOCAL Normal Operation Alarms & Errors Alarms & ErrorsPrimary Alarms Secondary Alarms Alarms & Errors INTRAC-305Alarm Outputs Recovering from AlarmsErrors INTRAC-305 Alarms & ErrorsPower Failure IESS-412 DataDeliberately blank Technical Description Technical DescriptionTechnical Description INTRAC-305 Modes Technical Description Auto normal operating modeUsing either IESS-412 or Norad data. see Reserve Model 72hrs, the beacon is still not producing a useful signal*Where the satellite’s position is only roughly known search High accuracy of the model the tracking is within 0.05dBManual mode or search mode see below before selecting Enters Standby. The antenna can then be peaked usingManually or in search mode see below. To commence During those scans and phase two of the search isUsing IESS-412 or Norad Data LMO value is given in the range -180to +180. Than two places of decimalsXNDT20 EpochXNDD60 BstarAntenna Motion Limits Axes Position Tracking SignalTechnical Description INTRAC-305 Installation InstallationConnections general Installation INTRAC-305Installation Connections Block DiagramRear Panel Layout Intractm 305 Resolvers Connector Connector PIN AllocationsMotor Control Signals to the Motor Drive CabinetStp-Trk Inputs / Alarm outputs Communication PortsRemote Port Test Port 1 & 2 RS422 Test Port 1 & 2 RS423Second PC connected to Test Port Data can be monitored during remote operation by using aINTRAC-305 Installation Tracking signal may be provided as a dc voltage from an Tracking Signal InputAppropriate drive command re-instated Emergency Stop switch is releasedOperational Checks Manual OperationAuto Operation Remote ControlFault Finding Fault FindingFault Symptoms Fault Finding INTRAC-305To power up Intrac doesn’t appearTWO Part Retaining PIN Enter Standby Mode System Alarm indicator to illuminate and the Intrac toSwitch consists of two normally closed N.C. contacts Pressing the switch opens both sets of contacts. The switchExample No Antenna DriveFault Finding INTRAC-305 Warranty & Repair Warranty & RepairWarranty Repair ServiceEffective repair technique and issue a repair cost estimate AMT Limited will investigate the fault, determine the mostCustomer either by a Purchase Order or through a Repair Contract