3-wire connection: Direct Wire
Use where local codes permit connecting
Direct wire cable must have 5 ft (1.52 m) of extra length so dryer can be moved if needed.
Strip 3¹⁄₂" (8.9 cm) of outer covering from end of cable. Strip insulation back 1" (2.5 cm). If using
1" (2.5cm)
3¹⁄₂" (8.9 cm)
When connecting to the terminal block, place the hooked end of the wire under the screw of the terminal block (hook facing right), squeeze hooked end together and tighten screw, as shown.
1. Loosen or remove center
2.Place the hooked end of the neutral wire (white or center wire) of power supply cable under the center screw of terminal block (hook facing right). Squeeze hooked end together. Tighten screw.
BC
D
AE
A. Neutral ground wire
B. External ground conductor screw
C. Center
D. Neutral wire (white or center wire)
E. ³⁄₄" (1.9 cm) UL listed strain relief
3.Place the hooked ends of the other power supply cable wires under the outer terminal block screws (hooks facing right). Squeeze hooked ends together. Tighten screws.
4.Tighten strain relief screw.
5.Insert tab of terminal block cover into slot of dryer rear panel. Secure cover with hold- down screw.
6.You have completed your electrical connections. Now go to “Venting Requirements.”