Maytag MDE17MN Vent System Length, Multiple Dryer Venting, Maximum Vent Length

Page 6

Plan installation to use the fewest number of elbows and turns.

AB

Exhaust Air Flow

A.Good

B.Better

Allow as much room as possible when using elbows or making turns. Bend vent gradually to avoid kinking.

Vent outlet is located at the center of the bottom dryer back.

The vent can be routed up, down, left, right, behind the dryer, or straight out the back of the dryer.

Vent System Length

Maximum length of vent system depends upon the type of vent used, number of elbows, and type of exhaust hood.

Maximum Vent Length

102 mm (4") Diameter Exhaust Hoods

Rigid Metal Vent

Each vent should enter the main vent at an angle pointing in the direction of the airflow. Vents entering from the opposite side should be staggered to reduce the exhausted air from interfering with the other vents.

The maximum angle of each vent entering the main vent should be no more than 30°.

A

30° max.

air flow

 

 

B

 

 

 

 

 

 

A. Individual dryer vent

B. Main vent

Keep air openings free of dry cleaning fluid fumes. Fumes create acids which, when drawn through the dryer heating units, can damage dryers and loads being dried.

A clean-out cover should be located on the main vent for periodic cleaning of the vent system.

If an exhaust hood cannot be used:

B

A

C

D

No. of 90° turns

Box Hood and Louvered Style

Angled Hood Style

 

 

 

0

19.5 m (64 ft.)

17.7 m (58 ft.)

1

16.5 m (54 ft.)

14.6 m (48 ft.)

2

13.4 m (44 ft.)

11.6 m (38 ft.)

3

10.7 m (35 ft.)

8.8 m (29 ft.)

4

8.2 m (27 ft.)

6.4 m (21 ft.)

If dryer is installed in a confined area, such as a bedroom, bathroom, or closet, provision must be made for enough air for combustion and ventilation. (Check governing codes and ordinances.) See “Recessed Area and Closet Installation Instructions” in the “Location requirements” section.

Min. 30 cm (12") clearance above any accumulation of snow, ice, or debris such as leaves.

C

A. Exhaust hood or elbow

B.Wall

C.Main collector vent

D.Horizontal vent

E.180° sweep elbow

F.Vertical vent

G.Roof

 

E

 

61 cm (24") min.

 

above highest

F

point of building

 

G

A 10.2 cm (4") outlet hood is preferred. However,a 6.4 cm (212") outlet exhaust hood may be used. A 6.4 cm (212") outlet creates greater back pressure than other hood types. For permanent installation, a stationary vent system is required.

Multiple Dryer Venting

A main vent can be used for venting a group of dryers. Main vent should be sized to remove 5663 l/min (200 CFM) of air per dryer. Large-capacity lint screens of proper design may be used in the main vent if checked and cleaned frequently. The room where the dryers are located should have make-up air equal to or greater than the airflow of all the dryers in the room.

Back-draft Damper Kit, Part No. 3391910, is available from your dealer and should be installed in each dryer’s vent to prevent exhausted air from returning into the dryers and to keep the exhaust in balance within the main vent.

Unobstructed air openings are required.

The outside end of the main vent should have a sweep elbow directed downward. If the main vent travels vertically through the roof, rather than through the wall, install a 180° sweep elbow on the end of the vent at least 61 cm (2 ft.) above the highest part of the building. The opening in wall or roof shall have a diameter 13 mm (12") larger than the vent diameter. The vent should be centered in the opening.

Do not install screening or cap over the end of the vent.

6

Image 6
Contents Installation Instructions Commercial Dryer W10184536AÍndice Table of ContentsTable DES Matieres IndiceTools and Parts Dryer SafetyInstallation Requirements Tools neededMinimum Installation Clearances Product Dimensions 68.6 cm 27 dryerRecessed Area and Closet Installation Instructions Location RequirementsElectrical Requirements Venting RequirementsRecommended Earthing Method Maximum Vent Length Vent System LengthMultiple Dryer Venting 102 mm 4 Diameter Exhaust HoodsInstall Leveling Legs Complete InstallationElectrical Connection If dryer does not operate check the following Maintenance InstructionsMaintenance instructions If you need assistanceOutillage et pièces Exigences D’INSTALLATIONSecurite DU SECHE-LINGE Outillage nécessaireExigences d’emplacement Distances de séparation minimalesEncastrement, vue avant Dimensions du produit Sèche-linge de 68,6 cm Méthode recommandée pour la mise à la terreSpécifications électriques Exigences concernant l’évacuation Longueur du circuit d’évacuationLongueur maximale du conduit Évacuation multiple du sèche-linge Si une bouche de décharge ne peut être utilisée’air non obstrués sont requis Raccordement électrique Installation des pieds de nivellementAchever l’installation Raccordement du conduit d’évacuationSi le sèche-linge ne fonctionne pas, vérifier ce qui suit Instructions D’ENTRETIENInstructions d’entretien Si vous avez besoin d’assistancePiezas suministradas Seguridad DE LA Secadora Requisitos DE InstalaciónHerramientas necesarias Pinzas Cuchillo para masillaEspacios mínimos para la instalación Dimensiones del producto Secadora de 68,6 cmInstrucciones para la instalación empotrada o en armario Vista frontal en Vista lateral enRequisitos eléctricos Método recomendado de conexión a tierraLargo del sistema de ventilación Ventilación para múltiples secadorasLongitud máxima del ducto de escape Instalación de las patas niveladoras Conexión eléctricaSi no puede usarse una capota de ventilación Instrucciones DE Mantenimiento Conexión del ducto de escapeComplete la instalación Attrezzi necessari Requisiti D’INSTALLAZIONESicurezza DELL’ASCIUGATRICE Componenti in dotazioneSpazi minimi di installazione Dimensioni del prodotto asciugatrice da 68,6 cmIstruzioni di installazione incassata e in armadi Requisiti di ubicazioneRequisiti elettrici Asciugatrice elettrica Metodo di messa a terra consigliatoLunghezza massima dello scarico Lunghezza dell’impianto di scaricoScarico di asciugatrici multiple Diametro delle cappe di scarico 102 mmInstallazione dei piedini di regolazione Completamento dell’installazioneConnessione elettrica Connessione dello scarico Se l’asciugatrice non funziona controllare che Istruzioni DI ManutenzioneIstruzioni di manutenzione Per l’assistenzaImprimé aux É.-U Impreso en EE.UU. Stampato negli S.U.A 07/2008