Emerson 00825-0100-4716 Rosemount 3095 MultiVariable, Quick Installation Guide, Function/Variable

Page 15
Manual background

Quick Installation Guide

00825-0100-4716, Rev DA October 2009

Rosemount 3095 MultiVariable

Function/Variable

Fast Key Sequence

DP Sens Trim

1, 2, 2, 1, 1

DP Snsr Range

1, 3, 5, 1

DP URV

5

DP units

1, 3, 2, 1

Date

1, 3, 4, 4

Descriptor

1, 3, 4, 2

Diff pres damp

1, 4, 2, 4

Diff pres

1, 1, 1

Diff pres

2

Fld dev rev

1, 3, 4, 9, 2

Flo rate

1, 1, 4, 5

Flow Rate Special Units

1, 4, 5, 1

Flow Units

1, 3, 2, 5

GP Damping

1, 4, 2, 5, 4

GP Sens Trim

1, 2, 2, 1, 3

GP Units

1, 3, 2, 4

Gage (GP)

1, 1, 4, 4

Hardware rev

1, 3, 4, 9, 4

LCD Settings

1, 4, 3

Loop test

1, 2, 1, 1

Message

1, 3, 4, 3

Num req preams

1, 4, 1, 2, 2

Num resp preams

1, 4, 1, 2, 3

PV is

1, 1, 5, 1, 1

Poll addr

1, 4, 1, 2, 1

Process temp unit

1, 3, 2, 3

Process temp

1, 1, 4, 3

RS type

1, 3, 5, 10

RTD Config

1, 4, 2, 2

Range values

1, 3, 3

Reset

1, 2, 1, 3

SP Snsr Range

1, 3, 5, 2

SP Type

1, 3, 5, 3

SV is

1, 1, 5, 2, 1

Scaled D/A trim

1, 2, 2, 2, 2

Status group 1

1, 6

Totalizer

1, 4, 4

Totalizer Special Units

1, 4, 5, 2

TV is

1, 1, 5, 3, 1

Tag

1, 3, 1

Temp Sens Trim

1, 2, 2, 1, 4

Temp damp

1, 4, 2, 5, 3

Universal rev

1, 3, 4, 9, 1

View status

1, 2, 1, 2

Write protect

1, 3, 4, 8

Xmtr Var Slot Assn

1, 4, 1, 2, 4, 3

15

Image 15
Contents ¢00825-0100-4716/¤ Quick Installation GuideRosemount 3095 MultiVariable Fieldbus Protocol Rosemount 3095MF Series Flowmeter TransmitterIMPORTANT NOTICE Explosions could result in death or serious injuryProcess leaks may cause harm or result in death Electrical shock can result in death or serious injuryCertification Label Electronics Board Nameplate Module O-ring TRANSMITTER EXPLODED VIEWRTD Connector Terminal Block HART O-ring CoverSteam Flow Applications STEP 1 MOUNT THE TRANSMITTERLiquid Flow Applications Gas Flow ApplicationsSTEP 2 TRANSMITTER INSTALLATION Consider Housing RotationField Installation STEP 2 CONTINUED Figure 2. Alarm Jumper LocationFigure 3. Armored Shielded RTD Cable Figure 5. ATEX/IECEx Flameproof RTD Cable Cable Adapter 1/2-14 NPT Black Cable ConnectorCable Gland Black Cable Connector/ RTD Connector Figure 4. Shielded RTD CableFigure 6. Common Transmitter Assemblies Bolting ConsiderationsPTFE Based O-rings with Flange AdaptersFlange Adapter O-ring3095 Engineering Assistant EA for HART Software Installation STEP 3 SOFTWARE INSTALLATION3. Select Hart Modem Installing the HART Modem3095 Engineering Assistant EA for FOUNDATION Fieldbus STEP 3 CONTINUED24 Vdc Supply Current RL≥ 250Ω Meter STEP 4 CONNECT WIRING AND POWER UP HARTShield Wire Ground STEP 4 CONNECT WIRING AND POWER UP FIELDBUSPower Supply Power ConditionerBasic Configuration Parameters STEP 5 CONFIGURE THE TRANSMITTER HARTSetting the Loop to Manual Send the Configuration to the TransmitterFast Key Sequence STEP 5 CONFIGURE THE TRANSMITTER FIELDBUS To configure the AI BlockAI Block configuration parameters STEP 6 TRIM THE TRANSMITTER Using the Field CommunicatorUsing the Foundation Fieldbus AI Block Using the Foundation Fieldbus Host SystemRosemount 3095 HART Hazardous Locations Certifications PRODUCT CERTIFICATIONS Rosemount 3095 with HARTApproved Manufacturing Locations European Directive InformationCanadian Standards Association CSA European CertificationsSpecial Conditions for Safe Use IECEx Certifications HART INMETRO Certifications Conditions of CertificationChina NEPSI Certifications Special conditions for safe useL i ≈ Maximum Temperature of European Pressure Equipment Directive PED 97/23/EC Rosemount 3095 with FieldbusCombinations of Certifications ATEX Directive 94/9/ECCanadian Standards Association CSA Rosemount 3095 Fieldbus Hazardous Locations CertificationsNorth American Certifications FM ApprovalsSpecial conditions for safe use IECEx Certifications Fieldbus Quick Installation Guide Rosemount 3095 MultiVariableCombinations of Certifications Rosemount 3095 MultiVariable Quick Installation GuideRosemount 3095 MultiVariable Quick Installation GuideRosemount 3095 MultiVariable Quick Installation GuideRosemount 3095 MultiVariable Quick Installation Guide