Emerson 00825-0100-4716, 3095 manual Canadian Standards Association CSA, European Certifications

Page 19
Canadian Standards Association (CSA)

Quick Installation Guide

00825-0100-4716, Rev DA October 2009

Rosemount 3095 MultiVariable

Canadian Standards Association (CSA)

CExplosion Proof for Class I, Division 1, Groups B, C, and D. Dust-Ignition Proof for Class II/Class III, Division 1, Groups E, F, and G. CSA enclosure Type 4X suitable for indoor and outdoor hazardous locations. Provides nonincendive RTD connection for Class I, Division 2, Groups A, B, C, and D.Factory Sealed. Install in accordance with Rosemount Drawing 03095-1024. Approved for Class I, Division 2, Groups A, B, C, and D.

KIntrinsically Safe for Class I, Division 1, Groups A, B, C, and D. when installed in accordance with Rosemount drawing 03095-1021. Temperature Code T3C.

For input parameters and installation see control drawing 03095-1021.

European Certifications

FATEX Intrinsic Safety

Certificate Number: BAS98ATEX1359X European Certifications II 1 G

Ex ia IIC T5 (Tamb = –45 °C to 40 °C) Ex ia IIC T4 (Tamb = –45 °C to 70 °C) Special Conditions for Safe Use 1180

Table 3. Connection Parameters (Power/Signal Terminals)

Ui = 30V

Ii = 200 mA

Pi = 1.0 W

Ci = 0.012 µF

Li = 0

Table 4. Temperature Sensor Connection Parameters

Uo = 30V

Io = 19 mA

Po = 140 mW

Ci = 0.002 µF

Li = 0

Table 5. Connection Parameters for Temperature Sensor Terminals

Co = 0.066 ￿F

Gas Group IIC

Co = 0.560 ￿F

Gas Group IIB

Co = 1.82 ￿F

Gas Group IIA

Lo = 96 mH

Gas Group IIC

Lo = 365 mH

Gas Group IIB

Lo = 696 mH

Gas Group IIA

Lo/Ro = 247 ￿H/ohm

Gas Group IIC

Lo/Ro = 633 ￿H/ohm

Gas Group IIB

Lo/Ro= 633 ￿H/ohm

Gas Group IIA

Special Conditions for Safe Use

The 3095, when fitted with the transient terminal block (order code B), are not capable of withstanding the 500 volts insulation test required by EN 60079-11, Clause 6.3.12. This condition must be accounted for during installation.

19

Image 19
Contents ¢00825-0100-4716/¤ Quick Installation GuideRosemount 3095 MultiVariable Fieldbus Protocol Rosemount 3095MF Series Flowmeter TransmitterIMPORTANT NOTICE Explosions could result in death or serious injuryProcess leaks may cause harm or result in death Electrical shock can result in death or serious injuryCertification Label Electronics Board Nameplate Module O-ring TRANSMITTER EXPLODED VIEWRTD Connector Terminal Block HART O-ring CoverSteam Flow Applications STEP 1 MOUNT THE TRANSMITTERLiquid Flow Applications Gas Flow ApplicationsConsider Housing Rotation STEP 2 TRANSMITTER INSTALLATIONField Installation Figure 2. Alarm Jumper Location STEP 2 CONTINUEDFigure 3. Armored Shielded RTD Cable Figure 5. ATEX/IECEx Flameproof RTD Cable Cable Adapter 1/2-14 NPT Black Cable ConnectorCable Gland Black Cable Connector/ RTD Connector Figure 4. Shielded RTD CableFigure 6. Common Transmitter Assemblies Bolting ConsiderationsPTFE Based O-rings with Flange AdaptersFlange Adapter O-ring3095 Engineering Assistant EA for HART Software Installation STEP 3 SOFTWARE INSTALLATION3. Select Hart Modem Installing the HART Modem3095 Engineering Assistant EA for FOUNDATION Fieldbus STEP 3 CONTINUED24 Vdc Supply Current RL≥ 250Ω Meter STEP 4 CONNECT WIRING AND POWER UP HARTShield Wire Ground STEP 4 CONNECT WIRING AND POWER UP FIELDBUSPower Supply Power ConditionerBasic Configuration Parameters STEP 5 CONFIGURE THE TRANSMITTER HARTSetting the Loop to Manual Send the Configuration to the TransmitterFast Key Sequence To configure the AI Block STEP 5 CONFIGURE THE TRANSMITTER FIELDBUSAI Block configuration parameters STEP 6 TRIM THE TRANSMITTER Using the Field CommunicatorUsing the Foundation Fieldbus AI Block Using the Foundation Fieldbus Host SystemRosemount 3095 HART Hazardous Locations Certifications PRODUCT CERTIFICATIONS Rosemount 3095 with HARTApproved Manufacturing Locations European Directive InformationEuropean Certifications Canadian Standards Association CSASpecial Conditions for Safe Use IECEx Certifications HART INMETRO Certifications Conditions of CertificationSpecial conditions for safe use China NEPSI CertificationsL i ≈ Maximum Temperature of European Pressure Equipment Directive PED 97/23/EC Rosemount 3095 with FieldbusCombinations of Certifications ATEX Directive 94/9/ECCanadian Standards Association CSA Rosemount 3095 Fieldbus Hazardous Locations CertificationsNorth American Certifications FM ApprovalsSpecial conditions for safe use IECEx Certifications Fieldbus Rosemount 3095 MultiVariable Quick Installation GuideCombinations of Certifications Rosemount 3095 MultiVariable Quick Installation GuideRosemount 3095 MultiVariable Quick Installation GuideRosemount 3095 MultiVariable Quick Installation GuideRosemount 3095 MultiVariable Quick Installation Guide