For example when the power button is pressed on the Northstar 15" Monitor it sends a + Volts signal through its Utility Cable (External Wake Up) to the Black Box Processors Utility Cable (Remote Power On). The processor detects the voltage and powers on. When the monitor is turned off, the 8000i Black Box Processor detects zero volts and and after (four) 4 seconds powers down.
NOTE: that the processor takes up to 30 Seconds to power down. This will not be visible on the 15" Monitor. Allow time for the processor to shut down before removing power to the system.
A | Yellow |
|
|
|
|
B | Black / White |
|
|
|
|
C | White |
|
|
|
|
D | Black |
|
|
|
|
E | Orange |
|
|
|
|
F | Blue |
|
|
|
|
G | Dark Green |
|
|
|
|
H | Grey | External Wake Up (Grey Wire) on the Utility Cable. |
|
| Connect this to the Light Green wire on the |
|
| Processor Utility Cable |
|
|
|
I | Light Green | Remote Power On wire connected to the Black Box |
|
| Processor |
|
|
|
J | Purple |
|
|
|
|
K | Pink |
|
|
|
|
Northstar 8000i System - 12" Display Processor Installation Manual
42