To add a new instrument:
1.Select Display then select Instruments. If you can't see the Select Panel button, select Return.
2.Choose Select Panel then select the instrument panel that you want to change and select Return.
3.Select Config then select Add Instrument. The Select Data Channel box is displayed.
4.The Active Channels button shows the current setting. If it's On, the 8000i shows the data channels that are currently receiving that data. (If it's Off, the 8000i shows all the data channels that are available.) Select the button to toggle the Active Channels button On, if necessary.
5.Select + next to the data channel that is most appropriate for the instrument that you're adding (for example, if you're adding a water temperature sensor, select + Environment). The 8000i lists the instrument data available from that data channel.
6.Select the instrument data that you want to show, then choose Next.
7.The new instrument is shown immediately on the selected Instruments screen in the top left corner.
8.You can select the new instrument and drag it to a new location on the instrument panel. The yellow lines help you to align the new instrument with the existing instruments.
9.When you are finished, select Save Changes
10.If you want to add another new instrument, select Add Instrument and repeat the procedure. Otherwise, select Return.
10.17.3Resize an instrument
You can use this to change the size of an instrument displayed on an instrument panel. The instrument can be set to small, medium, or large.
The default size is medium.
To resize an instrument:
1.Select Display then select Instruments. If you can't see the Select Panel button, select Return.
2.Choose Select Panel then select the instrument panel that you want to change and select Return.
3.Select Config from the control panel then select the instrument to be resized.
4.The Resize Instrument button shows the current setting. Select the button if you want to change the setting and a drop down list of choices appears.
5.Select the new setting then select Save Changes to confirm.
6.The new setting is applied immediately and stays until you change it again.
7.When you are finished, select Return.
10.17.4Rename an instrument panel
You can use this to change the name of an instrument panel.
To rename an instrument panel:
1.Select Display, then Instruments.
2.Choose Config, then Panel Config, then Rename Panel to display the Rename Panel box.
3.Select the instrument panel that you want to rename.
4.Select EDIT then enter the new name using the onscreen keyboard.
5.Select OK to confirm the new name.
6.When you are finished, select Return.
Northstar 8000i System - 12" Display Processor Installation Manual | 79 |