Function list (Extended function parameters)
|
|
|
|
|
| |||
|
|
|
|
|
|
| tions |
|
|
|
|
|
|
| ": Usable function | ||
Function | Parameter |
|
|
| Cus- | ×: Unusable function | ||
|
|
|
|
| * : Functions that can be used | |||
|
| Name | Outline | Factory | tomer | |||
|
| for param | ||||||
|
| Setting | Set- | |||||
|
|
|
|
| trol |
| ||
|
|
|
|
| ting |
|
| |
|
|
|
|
|
|
|
| |
|
|
|
|
|
| Vector Control | ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Speed | Torque | Position |
|
|
|
|
|
| control | control | control |
|
| 232 |
| By setting any value other than "9999", set speeds 8 to 15. |
|
| 9999 | " | " | × * | ||||||
|
|
| (speed 8) |
|
|
|
|
|
| |||||||
|
|
|
| This function is designed to change the running speed in stages by changing the ON/ |
|
|
|
| ||||||||
|
|
|
|
|
|
| × * | |||||||||
|
| 233 | OFF combination of the contact signals (RH, RM, RL, REX signals). | 9999 | " | " | ||||||||||
|
| (speed 9) | ||||||||||||||
|
|
|
|
|
|
|
|
|
|
| ||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 234 |
|
|
|
|
|
|
|
|
|
| 9999 | " | " | × * |
operation |
| Speed 9 |
| RH |
| RM | RL | REX |
| |||||||
235 | (speed 11) |
|
| OFF |
| OFF | ON | ON |
| 9999 | " | " | × * | |||
|
|
| (speed 10) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Speed 8 |
| OFF |
| OFF | OFF | ON |
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
| Speed 10 |
| OFF |
| ON | OFF | ON |
|
|
|
|
| ||
|
| 236 |
|
|
|
|
| 9999 | " | " | × * | |||||
|
|
|
|
|
|
|
|
|
|
| ||||||
|
|
| Speed 11 |
| OFF |
| ON | ON | ON |
| ||||||
|
| (speed 12) |
|
|
|
| ||||||||||
|
|
|
|
| Speed 12 |
| ON |
| OFF | OFF | ON |
|
|
|
|
|
|
| 237 |
| 9999 | " | " | × * | |||||||||
|
|
|
|
|
|
|
|
|
|
| ||||||
|
| (speed 13) |
| Speed 13 |
| ON |
| OFF | ON | ON |
| |||||
|
|
|
|
| Speed 14 |
| ON |
| ON | OFF | ON |
|
|
|
|
|
|
| 238 |
|
|
| 9999 | " | " | × * | |||||||
|
|
|
|
|
|
|
|
|
|
| ||||||
|
|
| Speed 15 |
| ON |
| ON | ON | ON |
| ||||||
|
|
| (speed 14) |
|
|
|
|
|
|
|
| |||||
|
| 239 |
| 0 to 3600r/min, 9999 |
|
|
|
|
|
| 9999 | " | " | × * | ||
|
|
| (speed 15) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| You can select to exercise | long wiring mode. When |
|
|
|
| |||||||
|
|
|
| control is made valid, you can change the metallic tone of motor sound into an |
|
|
|
| ||||||||
|
|
|
| unoffending complex tone. Surge voltage is surpressed in the long wiring mode |
|
|
|
| ||||||||
|
|
|
| regardless of the wiring length between the inverter and motor. (When operating a |
|
|
|
| ||||||||
functions | 240 |
| 400V motor with wiring length of 40m or more, select long wiring mode.) | 10 | " | " | " | |||||||||
10: | ||||||||||||||||
|
|
|
| 0: |
|
|
|
|
|
| ||||||
|
|
|
| 1: |
|
|
|
| ||||||||
Sub |
|
| 11: |
|
|
|
| |||||||||
|
|
| *The Pr.72 "PWM frequency selection" setting is made invalid. |
|
|
|
| |||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
| Cooling fan operation | You can control the operation of the cooling fan built in the inverter. |
|
|
|
| ||||||||
|
| 244 | 0: The fan is always operated at |
|
| 0 | " | " | " | |||||||
|
|
| selection | 1: The fan is always on while the inverter is running. During a stop, the inverter status is |
|
|
|
| ||||||||
|
|
|
| monitored and the fan switches |
|
|
|
| ||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
selectionStop | function |
|
| Set to allow the motor to be coasted to a stop by turning off the start command during |
|
|
|
| ||||||||
|
|
|
|
|
|
|
| |||||||||
|
| 250 | Stop selection | V/F or speed control. |
|
|
|
|
|
| 9999 | " | " | × | ||
|
| 0 to 100s: Coasting to stop |
|
|
|
|
|
| ||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
|
|
|
| 9999: Deceleration to stop |
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
selectionOperation | function |
| Output phase failure | You can disable the output phase failure function that stops the inverter output if one of |
|
|
|
| ||||||||
|
|
|
|
|
|
| ||||||||||
|
| 251 | the inverter output side (load side) three phases (U, V, W) opens. | 1 | " | " | " | |||||||||
|
|
| protection selection | 0: Without output phase failure protection |
|
|
|
|
|
|
|
| ||||
|
|
|
| 1: With output phase failure protection |
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Additional | functions | 253 | Override gain |
|
|
|
|
|
|
|
|
| 150% | " | " | × |
|
| 252 | Override bias | When you selected the override in Pr. 73, you can adjust the override bias (0 to 200%) | 50% | " | " | × | ||||||||
|
|
|
| and override gain (0 to 200%). |
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
| |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
| 261 | Power failure stop | You can select the stopping method at a power failure. |
|
|
| " | " | × | ||||||
|
| 0: Coasting to stop, inverter output shutoff |
|
|
| 0 | ||||||||||
|
|
| selection | 1: Inverter is decelerated to a stop. |
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
| |||||
functions |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
263 | Subtraction starting | 0 to 3600r/min, 9999 |
|
|
|
|
|
| 1500r/m in | " | " | × | ||||
|
| 262 | Subtracted speed at | 0 to 600r/min |
|
|
|
|
|
| 90r/min | " | " | × | ||
|
|
| deceleration start |
|
|
|
|
|
|
|
|
|
|
|
|
|
stop |
| speed |
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
failure | 264 |
| 0 to 3600/0 to 360s |
|
|
|
|
|
| 5s | " | " | × | |||
| deceleration time 1 |
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
Power | 265 |
| 0 to 3600/0 to 360s, 9999 |
|
|
|
|
|
| 9999 | " | " | × | |||
| deceleration time 2 |
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| × |
|
| 266 | deceleration time | 0 to 3600r/min |
|
|
|
|
|
| 1500r/m in | " | " | |||
|
|
| switchover speed |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 278 | Brake opening speed |
|
|
|
|
|
|
|
|
| 20r/min | " | × | × |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 279 | Brake opening |
|
|
|
|
|
|
|
|
| 130% | " | × | × |
|
|
| current |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 280 | Brake opening | Set when outputting the operation timing signal of the mechanical brake in vertical lift | 0.3s | " | × | × | ||||||||
|
| current detection time | ||||||||||||||
sequence | applications. (When speed control (invalid for V/F control) is selected) | |||||||||||||||
282 | Brake operation speed | 0 to 5s (Pr. 281) |
|
|
|
|
|
| 25r/min | " | × | × | ||||
|
| 281 | Brake operation time | 0 to 900r/min (Pr. 278) |
|
|
|
|
|
| 0.3s | " | × | × | ||
|
| at start | 0 to 200% (Pr. 279) |
|
|
|
|
|
| |||||||
Brake |
|
| 0 to 2s (Pr. 280) |
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
| |||||
|
| 0 to 900r/min (Pr. 282) |
|
|
|
|
|
|
|
|
|
| ||||
|
| 283 | Brake operation time |
|
|
|
|
|
| 0.3s | " | × | × | |||
|
| 0 to 5s (Pr. 283) |
|
|
|
|
|
| ||||||||
|
|
| at stop | 0, 1 (Pr. 284) |
|
|
|
|
|
|
|
|
|
| ||
|
|
| Deceleration | 0 to 900r/min, 9999 (Pr. 285) |
|
|
|
|
|
|
|
| × | × | ||
|
| 284 | detection function |
|
|
|
|
|
|
|
|
| 0 | " | ||
|
|
| selection |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 285 | Overspeed detection |
|
|
|
|
|
|
|
|
| 9999 | " | × | × |
|
|
| speed |
|
|
|
|
|
|
|
|
|
|
|
|
|