AEG 8000012364 BAL Duty to Provide Information, Validity, Warranty, Handling

Page 2

"UniVert 2" inverter

Notes on these Operating Instructions

Duty to Provide Information

These operating instructions must be read carefully by all persons working with or on the inverter system prior to installation and initial start-up.

These operating instructions are a composite part of the inverter system.

The operator of this unit is obliged to make these operating instructions available to all personnel transporting or starting up units, or performing maintenance or any other work on the unit.

Validity

These operating instructions comply with the current technical specifications of the inverter system at the time of publication. The contents do not constitute a subject matter of the contract, but serve for information purposes only.

AEG reserves the right to make modifications with regard to contents and technical data in these operating instructions without prior notification. AEG cannot be held liable for any inaccuracies or inapplicable information in these operating instructions, as no obligation to continuously update the data and maintain their validity has been entered into.

Warranty

Our goods and services are subject to the general conditions of supply for products of the electrical industry, and our general sales conditions. We reserve the right to alter any specifications given in these operating instructions, especially with regard to technical data, operation, dimensions and weights. Claims in connection with supplied goods must be submitted within one week of receipt, along with the packing slip. Subsequent claims cannot be considered.

AEG will rescind all obligations such as warranty agreements, service contracts, etc. entered into by AEG or its representatives without prior notice in the event of maintenance and repair work being carried out with anything other than original AEG parts or spare parts purchased by AEG.

Handling

These operating instructions are structured so that all work necessary for start-up, maintenance and repair of the units can be performed by qualified personnel.

Illustrations are provided to clarify and facilitate certain steps.

If danger to personnel and equipment cannot be ruled out in the event of certain work, it is highlighted accordingly by pictograms explained in chapter 1, Safety Instructions.

Page 2 of 42

8000012364 BAL, en

Image 2
Contents Operating Instructions UniVert 2 inverter and SBS option Validity WarrantyDuty to Provide Information HandlingCopyright AbbreviationsHotline Table of Contents Dimensional Drawing Maintenance TroubleshootingTechnical Data Accident Prevention Regulations Safety InstructionsImportant Instructions and Explanations Qualified Personnel Safety Awareness ApplicationLiability DirectivesGeneral Information System DescriptionParallel INV operation Function of the SystemIndividual INV operation Individual or parallel operation with SBSParallel INV operation Block diagram of the inverter Description of the INVPrinciple of Operation of the INV, Electrical Description of the SBS SBSPrinciple of Operation of the SBS, Electrical Function of the Inverter Can Bus Interfaces X6 ON/OFF SwitchDIL Switch S2.1 S2.2 S2.3INVs Settings must be the same on all INVs and the SBS Switches S2.4, S2.5 and S2.6 Own Address INVSwitches S2.7 and S2.8 Number of redundant INVs S2.4 S2.5 S2.6 AddressSignalling, Displays and Remote Signals Display Colour Operating statusOperating Statuses Switchback AttemptsFunction of the SBS optional AC Busbar Reset ButtonAC Mains Input AC Mains Monitoring SystemS3.1 S3.2 S3.3 S3.7 S3.8 INVs Operating modes Assignment of the signal terminalsSwitchover without gap Switchover with gap Start-Up InstallationConnecting the Loads / DC / Mains ConnectionDisconnection Maintenance For systems with SBS additionally TroubleshootingOutput Voltage Deviation Technical Data General Data INVCollective fault FaultOvertemperature ϑ OperationGeneral Data SBS With safe isolation at UO ≤ 60 V DC UniVert 2 inverter Electrical Data At 24 Type E-number G110 E230/10,9/2rfg-CFp2,5 3000000263 Type E-number E230 E230/115/2-VFp26,5-8 3000000646 Dimensional Drawing Inverter dimensions type 1.5 and 3.3 kVAInverter dimensions type 2.5 kVA SBS dimensions