AEG 8000012364 BAL operating instructions UniVert 2 inverter

Page 35

"UniVert 2" inverter

Protection class

IP 20

 

Cooling

Forced air cooling

 

Intake air temperature

At rated current 0°C to 45°C,

 

measured below the SBS

Storage temperature

-20°C to +70°C

 

Ambient conditions

IEC 721 Part 3-3 Class 3K3 / 3Z1 /

 

3B1 / 3C2 / 3S2 / 3M3

Site altitude

Up to 2000 m above sea level

Mechanical stability

 

 

and vibration resistance

In acc. with VDE 0160

 

Version 5.88 Item 7.2.2

Surface painted with

RAL 7032 (front panel)

Dimensions (W x H x D)

483 x 174 x 400 mm

 

 

(19" x 4 height modules)

Weight

Approx. 13.5 kg

 

Noise generation

< 50 dB(A)

 

Connection system

 

 

X1 AC mains input:

Screw terminal 10 ...

25 mm2

X2 AC output:

Screw terminal 10 ...

25 mm2

X4 remote signals:

Screw terminal 0.2 ...

2.5 mm2

PE conductor:

M4 thread

 

X6 CAN bus interface

10-pin socket connector with

 

insulation displacement

 

connection system

 

 

in acc. with DIN 41651

X7 CAN bus interface

16-pin socket connector with

 

insulation displacement

 

connection system

 

 

in acc. with DIN 41651

Page 35 of 42

8000012364 BAL, en

Image 35
Contents Operating Instructions UniVert 2 inverter and SBS option Handling WarrantyDuty to Provide Information ValidityCopyright AbbreviationsHotline Table of Contents Dimensional Drawing Maintenance TroubleshootingTechnical Data Accident Prevention Regulations Safety InstructionsImportant Instructions and Explanations Qualified Personnel Application Safety AwarenessDirectives LiabilitySystem Description General InformationIndividual or parallel operation with SBS Function of the SystemIndividual INV operation Parallel INV operationParallel INV operation Description of the INV Block diagram of the inverterPrinciple of Operation of the INV, Electrical SBS Description of the SBSPrinciple of Operation of the SBS, Electrical Function of the Inverter S2.1 S2.2 S2.3 ON/OFF SwitchDIL Switch Can Bus Interfaces X6S2.4 S2.5 S2.6 Address Switches S2.4, S2.5 and S2.6 Own Address INVSwitches S2.7 and S2.8 Number of redundant INVs INVs Settings must be the same on all INVs and the SBSDisplay Colour Operating status Signalling, Displays and Remote SignalsOperating Statuses Switchback AttemptsFunction of the SBS optional AC Mains Monitoring System Reset ButtonAC Mains Input AC BusbarS3.1 S3.2 S3.3 S3.7 S3.8 INVs Operating modes Assignment of the signal terminalsSwitchover without gap Switchover with gap Connection InstallationConnecting the Loads / DC / Mains Start-UpDisconnection Maintenance For systems with SBS additionally TroubleshootingOutput Voltage Deviation General Data INV Technical DataOperation FaultOvertemperature ϑ Collective faultGeneral Data SBS With safe isolation at UO ≤ 60 V DC UniVert 2 inverter Electrical Data At 24 Type E-number G110 E230/10,9/2rfg-CFp2,5 3000000263 Type E-number E230 E230/115/2-VFp26,5-8 3000000646 Inverter dimensions type 1.5 and 3.3 kVA Dimensional DrawingInverter dimensions type 2.5 kVA SBS dimensions