"UniVert 2" inverter
Type E-number
G110 E230/10,9/2rfg-CFp2,5
3000000263
Rated output capacity | 2.5 kVA |
|
|
with power factor | 0.8 |
|
|
Power factor range | 0 inductive to 0 capacitive |
|
|
Rated output voltage | 230 V ±0.5 static, ±3% dynamic at 100% load change |
|
|
Output frequency | 50 Hz ±0.05% |
|
|
THD factor | < 3% |
|
|
Rated output current | 10.9 A |
|
|
DC rated input voltage | 110 V |
|
|
DC rated current | 20.4 A at 110 V |
|
|
Efficiency | >88% |
|
|
DC input current ripple | < 50% of DC rated current |
|
|
Monitoring systems |
|
|
|
DC undervoltage, | Fault < 85% of 110 V (93.5 V), without delay |
| Acknowledgement > 103% of 110 V (113.3 V), 15 s delay |
|
|
DC overvoltage, | Fault > 128% of 110 V (140.8 V), without delay |
| Acknowledgement < 125% of 110 V (137 V), 15 s delay |
|
|
AC undervoltage, | Fault < 90% rated (207 V), 2.5 s delay |
| Acknowledgement by ON/OFF switch |
|
|
Overtemperature, | Fault > 80 °C, acknowledgement < 70 °C, approx. 5 s delay |
|
|