4.4.3 Digital inputs - X3
Digital inputs DIN0 to DIN3 can be used as high speed position latches. The fast position inputs are routed through a programmable
12 | Location | Breakout module, connector X3 | ||
|
|
|
| |
| Pin | Name | MintMT keyword / description | |
|
|
|
| |
| 1 | DIN0 | INX.0 | |
|
|
|
| |
| 2 | Common1 | Common connection | |
|
|
|
| |
| 3 | Shield | Shield connection | |
1 |
|
|
| |
4 | DIN1 | INX.1 | ||
| ||||
|
|
|
| |
| 5 | Common1 | Common connection | |
|
|
|
| |
| 6 | Shield | Shield connection | |
|
|
|
| |
| 7 | DIN2 | INX.2 | |
|
|
|
| |
| 8 | Common1 | Common connection | |
|
|
|
| |
| 9 | Shield | Shield connection | |
|
|
|
| |
| 10 | DIN3 | INX.3 | |
|
|
|
| |
| 11 | Common1 | Common connection | |
|
|
|
| |
| 12 | Shield | Shield connection | |
|
|
|
| |
| Description |
|
| |
| Four fast position digital inputs. |
| ||
| Sampling frequency: 1kHz (MintMT) | |||
|
|
|
|
Note: Digital inputs DIN0 to DIN3 are particularly sensitive to noise, so inputs must use shielded twisted pair cable.
NextMove PCI
3k3
DINx
Common1
Active high:
DINx =
Common1 = 0V
Vcc
MintMT
TLP115
Active low: DINx = 0V
Common1 =
Figure 4 - Digital input circuit - fast interrupts
| MN1903 |