HTerminators must only be fitted at both ends of the network, not at intermediate nodes.
HThe 0V connection of all of the nodes on the network must be tied together through the CAN cabling. This ensures that the CAN signal levels transmitted by NextMove PCI or CAN peripheral devices are within the common mode range of the receiver circuitry of other nodes on the network.
4.6.1CAN1 (CANopen) - X17
CANopen connections are made using the breakout module connector X17.
15
6 9
Location | Breakout module, connector X17 | |
|
|
|
Pin | Name | Description |
|
|
|
1 | Shield | Cable shield |
|
|
|
2 | CAN1- | CAN channel 1 negative |
|
|
|
3 | CAN1 GND | CAN1 Ground / earth reference |
|
|
|
4 | - | (NC) |
|
|
|
5 | - | (NC) |
|
|
|
6 | - | (NC) |
|
|
|
7 | CAN1+ | CAN channel 1 positive |
|
|
|
8 | - | (NC) |
|
|
|
9 | CAN1 V+ | CAN1 power |
|
|
|
Description
CANopen interface using a
If NextMove PCI is at the end of the CANopen network the termination resistor must be connected by fitting the termination jumper J8, labelled “CO Term”, on the breakout module.