Invacare Top End T-3 Adjusting Wheelbase Width Figure, Adjusting Wheelbase Width A-4 Camber Tube

Page 44

WHEELS

PROCEDURE 6

WHEELS

 

 

ADJUSTING WHEELBASE WIDTH (FIGURE 14)

ADJUSTING WHEELBASE WIDTH - A-4 CAMBER TUBE

NOTE: Perform this procedure one (1) side of the wheelchair at a time for ease of adjustment.

1.Open the camber clamps. Refer to OPENING/CLOSING CLAMPS in this procedure of the manual.

WARNING

NEVER position the camber inserts in the axle tube with more than 3-inches (12 indexing marks showing) of the camber insert outside of the axle tube. The camber inserts will not be securely tightened in the axle tube resulting in possible injury to the user or damage to the wheelchair.

2.Position the camber insert to the desired position. Make sure there is no more than 3-inches (12 indexing marks showing) of the camber inserts outside of the axle tube.

3.Slide the indexing ring on the camber insert until it is flush with the frame bracket.

NOTE: Before using the wheelchair, make sure both camber inserts are set at the same indexing mark. This will make sure the distance between the rear wheel and the wheelchair is the same on both sides.

WARNING

QUICK RELEASE LEVERS - Make sure the quick release levers are pointing towards the rear of the wheelchair and is in the CLOSED position BEFORE using the wheelchair, otherwise personal injury or damage to the wheelchair may result.

STANDARD - Make sure the hex screws and locknuts are securely tightened BEFORE using the wheelchair, otherwise personal injury or damage to the wheelchair may result.

4.Close the camber clamps. Refer to OPENING/CLOSING CLAMPS in this procedure of the manual.

5.Repeat STEPS 1-4 for the opposite side of the wheelchair.

A-4 CAMBER TUBE

Indexing Marks

Indexing Ring

 

 

Axle Tube

Camber Insert

Frame Bracket

CAMBER TUBE 2000

NOTE: Axle bolt removed from axle tube for clarity. It is not necessary to remove the axle bolt for this procedure.

Axle Nut

Threads

Axle Bolt

FIGURE 14 - ADJUSTING WHEELBASE WIDTH

T-3™ and T-4™ Series

44

Part No. 1054916

Image 44
Contents Owners Operator And Maintenance Manual Special Notes Special NotesTable of Contents Register Your Product Complete and mail this form Name AddressZip/Postal Code Email Phone No Invacare Model No. Serial NoFold here Cut Along Line Typical Product Parameters Typical Product ParametersSee current order form 250 lbs See current order form Procedure General Guidelines StabilityGeneral Guidelines Stability WarningsGeneral Warnings Continuted Tire Pressure Weight TrainingWeight Limitation SAFETY/HANDLING of Wheelchairs Stability and BalanceProcedure General Guidelines Coping with Everyday Obstacles Percentage of Weight DistributionAdjustable Models Only Functional Reach from a WheelchairGuidelines Shortening FrontTilting Do not tilt the chair without assistanceStairways ESCALATORS? Sorry Transferring to and from Other SeatsSafety Inspection Safety Inspection ChecklistSafety Inspection Safety Inspection Checklist Maintenance Safety Inspection ProcedureMaintenance Safety Precautions Suggested Maintenance ProceduresADJUSTING/REPLACING Back Upholstery Figure Procedure BackAdjusting Back Upholstery BackFolding Back Figure Replacing Back UpholsteryBack Height Adjustment Figure Back Angle Adjustment FigureHole Number 11-14 14-18 16-20Back Angle to Seat Rail Seat Seat Upholstery Replacement FigureProcedure Seat Rear Seat Height Adjustment Rear Seat to Floor Range in InchesFront Seat Height Adjustment Front Seat Height Adjustment BeforeNylon Clothing Guard with Plastic Insert Replacement Figure Rigid Clothing Guard Replacement FigureClothing Guards ClothingREMOVING/INSTALLING Rear Wheels Figure Procedure WheelsWheels Quick or QUAD-RELEASE AxlesAdjusting QUICK-RELEASE Axles Figure REMOVING/INSTALLING Rear WheelsINSTALLING/ADJUSTING QUAD-RELEASE Axles Installing FigureRemoving Play From Rear Wheels Adjusting FigureAdjusting Quad-Release Handles In And/Or Out Do not inflate tire until handrim is completely assembled Handrim Replacement FigureREPAIRING/REPLACING Rear WHEEL, TIRE/TUBE Open Position OPENING/CLOSING Clamps FigureQUICK-RELEASE Lever Standard Closed Position Determining TOE IN/TOE OUT Figure Detail a Measuring the Centerlines TOP ViewWheelchair Front WheelchairAdjusting TOE IN/TOE OUT Camber InsertsOr 6/12 Camber Inserts Or 12 CamberWheels Axle Tube Will Rotate UP Only Adjusting Rear Wheel Camber Figure Elite and T-4 Models with Fixed Camber FigureCamber Insert Adjustment RequiredAdjusting Wheelbase Length Adjusting Center Gravity Detail a Measuring Frame Bracket DistanceCamber Tube Adjusting Wheelbase Width FigureAdjusting Wheelbase Width A-4 Camber Tube Adjusting Wheelbase Width Camber Tube Replacing Axle Tube FigureReplacing Axle Tube Front Caster Replacement Figure Adjusting Front Caster Height FigureInstalling QUICK-RELEASE Casters Figure Installing Quick Release CastersReplacing the HIGH/LOW Mount Wheel Lock Wheel Lock ADJUSTMENT/REPLACEMENT FigureAdjusting the HIGH/LOW Mount Wheel Locks Procedure Footrest FootrestWheelchair Frame Mounting Bracket Hex Screw Procedure Footrest Adjusting Footrest Height AdjustmentDepth Adjustment Tennis Elite Individual Footplates Before 4/2000 Figures 2Footrest Procedure Changing Footplate Angle Changing Footplate DepthChanging Footplate Height Repositioning FootplateProcedure Footrest Removing Footplates Installing FootplatesRemoving Footplate System Mounting Clamp Replacing Footplate Mounting BracketFootrest Procedure 3 Tennis Elite Individual FootplatesReplacing Individual Footplates Tennis Adjustable Footrest System Before 4/2000 FigureAdjusting Individual Footplates Footrest Procedure Replacing Footplate Weldment Replacing Seat Adjustment WeldmentProcedure Footrest REPLACING/ADJUSTING Fixed ANTI-TIPPER Swivel Caster Optional ANTI-TIPPER ProcedureReplacement Elite and T-4 Elite with Fixed Camber Tube FigureAdjusting AssembleddisassembledANTI-TIPPER INSTALLING/ADJUSTING Removable ANTI-TIPPEROptional Anti-Tipper Push Mounting Holes Warranty WarrantyCanada