6mm
13mm
<15kgF |
SETTING MECHANICAL CLUTCH (A5 ONLY)
-Isolate MAINS POWER.
-Remove fan from motor to expose the motor shaft (where applicable).
Ensure fan has stopped turning.
-Lock shaft using 13mm spanner and use 6mm allen key to adjust sensitivity - Clockwise to increase force.
-Recommended maximum push force should not exceed 15kgF.
14