Centurion CP72SR5 Mechanical Mounting Details, Option 1 Bolt down onto concrete plinth

Page 8

MECHANICAL MOUNTING DETAILS

Option 1 - Bolt down onto concrete plinth

-Ensure motor does not protrude into drive-way install baseplate with centre line 250mm off pillar centre.

-Position baseplate (43) with centre of single support stud (45) 105mm from edge of gate (46). (This dimension assumes centre line of rack (47) is 20mm from edge of gate).

-Using the baseplate as a template mark and drill the 4 mounting holes into the concrete for the four M10 x 95 expansion studs.

-Use two M12 plated nuts per expansion stud as spacers below the foundation plate.

-Secure the baseplate to the expansion studs using one M10 washer and nut per expansion stud.

43

47

46

45

105mm

20mm

C

L

6

Image 8
Contents Sliding Gate Automation Page Oil Specifications Grade 75W90 Qty 75ml Major Components Typical D5 ShownStart kgF RUN kgF Gate Mass kg 300 500 ANTI-LIFT Brackets Duty Cycle Curves Recommended Installation and Cable Thickness REQUIREMENTS† Mechanical Mounting Details Option 1 Bolt down onto concrete plinthPage Option 2 Set into concrete plinth Provision for Cables Gearbox Mounting Down Details Mounting Rack Useful TIP200mm Installing Chain Drive Systems Setting Mechanical Clutch A5 only Ensure fan has stopped turningMounting Configuration For Steel Rack Mounting of Gate SensorPower Wiring see page 15 for Signal Wiring Removable ConnectorsSignal Wiring CP80 and CP81 Recommended Lightning Protection Commissioning Block Diagram Setting Motor Direction Gate Closes Towards Left Above Black Blue RED Towards RightSelecting Programme Mode Setting Gate Limits A5 onlySetting Gate Limits Start Automated Gate Limits RoutineD3/D5 Motor Automatic SET-UP Exit Gate Limits Routine D3/D5 only Start Manual Gate Limits RoutineAlign Origin Switch A5 Motor Manual SET-UPExit Gate Limits Routine A5 only Functions SelectFactory Defaults Highlighted Timer and Counter Setting Main Unit Menu Measure Procedure to Programme Controller Back to Factory Settings Fault Finders Guide D3 / D5 OperatorsGate Opens to Pedestrian and Closes Page Centurion