D3/D5 MOTOR AUTOMATIC SET-UP
1
2
3
1- Gate starts at “crawl” speed to open gate.
NB. If gate closes, remove power and reverse motor wires (see page 20)
2- Gate hits “open” end stop and reverses direction running at crawl speed.
3 - Gate hits “closed” end stop and reverses direction running at “FULL” speed until the marker, then at CRAWL speed to end.
4
5
6
4 - Gate hits “open” end stop and reverses but now runs at “FULL” speed.
5 - As gate sensor passes the motor, the speed reduces to CRAWL. Gate hits “closed” end stops and reverses
at FULL SPEED.
6 - Gate stops at “pedestrian” (PED) position. If required, widen PED opening by pulsing PED input.
24