Centurion CP72SR5 Mounting of Gate Sensor, Mounting Configuration For Steel Rack

Page 17

MOUNTING CONFIGURATION

FOR STEEL RACK

BOLT USING

WELD

FASTENERS66

MOUNTING

PROVIDED

BRACKET

PROVIDED TO

STEEL RACK

ORIGIN MARKER

BRACKET

66

A

68

 

GREATER THAN 500mm

66

B

 

 

66

C

13-20mm

 

68

MOUNTING OF GATE SENSOR

-With the gate in the CLOSED position, mount the origin marker (66) a minimum 500mm from the origin sensor (68). (See isometric view (A) or plan view (B) above).Please note this distance will affect the pedestrian opening distance. For

minimum pedestrian opening, mount the origin marker at 500mm. The maximum distance of the origin marker is limited by the marker having to pass the sensor by no less than 500mm before the gate opens fully. If a longer crawling distance is required, the position of the marker needs to be changed (see table 3 on page 30).

-Manually slide gate OPEN until origin marker (66) is in line with the origin sensor (68). Ensure distance between face of marker (66) and front face of sensor (68) is between 13 and 20mm. (See (C) above)

-Adjust distance by sliding the origin marker (66) along the slotted mounting holes until desired distance is achieved.

15

Image 17
Contents Sliding Gate Automation Page Major Components Typical D5 Shown Oil Specifications Grade 75W90 Qty 75mlStart kgF RUN kgF Gate Mass kg 300 500 ANTI-LIFT Brackets Duty Cycle Curves Recommended Installation and Cable Thickness REQUIREMENTS† Option 1 Bolt down onto concrete plinth Mechanical Mounting DetailsPage Option 2 Set into concrete plinth Provision for Cables Gearbox Mounting Down Details Useful TIP Mounting Rack200mm Installing Chain Drive Systems Ensure fan has stopped turning Setting Mechanical Clutch A5 onlyMounting of Gate Sensor Mounting Configuration For Steel RackRemovable Connectors Power Wiring see page 15 for Signal WiringSignal Wiring CP80 and CP81 Recommended Lightning Protection Commissioning Block Diagram Gate Closes Towards Left Above Black Blue RED Towards Right Setting Motor DirectionSelecting Programme Mode A5 only Setting Gate LimitsStart Automated Gate Limits Routine Setting Gate LimitsD3/D5 Motor Automatic SET-UP Start Manual Gate Limits Routine Exit Gate Limits Routine D3/D5 onlyA5 Motor Manual SET-UP Align Origin SwitchFunctions Select Exit Gate Limits Routine A5 onlyFactory Defaults Highlighted Timer and Counter Setting Main Unit Menu Measure Fault Finders Guide D3 / D5 Operators Procedure to Programme Controller Back to Factory SettingsGate Opens to Pedestrian and Closes Page Centurion