Mount the Transmitter

For dimensional drawing information refer to Appendix A: Reference Data.

Electronics Housing

Provide 0.75 inches (19 mm) of clearance for units without an LCD display. Three inches of clearance is required for cover removal if a meter is installed.

Cover Installation

Always ensure a proper seal by installing the electronics housing cover so the o-ring is engaged. Use Rosemount O-rings.

The Rosemount 4500 is designed to be mounted directly to a process pipe or vessel using a standard sanitary fitting. The transmitter is available with either a 1.5 or 2-inch Tri-Clamp®connection or a fractional line fitting.

When installing the transmitter to the sanitary fitting it is important to use the proper sanitary clamp and gasket (user-supplied). Check the clamp and gasket specifications before installing. Refer to Table 2-2for a list of standard sanitary clamps, their respective maximum pressure ranges, and the recommended torque to be applied when mounting.

Figure 2-3. Rosemount 4500

Mounting Configuration Using a

Sanitary Fitting

1.5 or 2-in. Tri-Clamp Connection

DETAIL OF SANITARY

CONNECTION

B

A

User

Supplied

Gasket and

Clamp

4500_04_AA.EPS, 4500_24_AA.EPS

Table 2-1. Connection Size

Description

Connection Size in (mm)

A

B

 

 

 

 

11/2 inch Tri-Clamp

1.50 (38)

1.99 (50)

1.71 (43)

2 inch Tri-Clamp

2.00 (51)

2.52 (64)

2.22 (56)

Fractional Line Fitting

1.50 (38)

1.99 (50)

1.50 (38)

Table 2-2. Standard Sanitary Clamp Models

Clamp Model

13MHHM 1.5-inch 13 MHHM 2-inch

13MHHS 1.5-inch 13 MHHS 2-inch 13 MHP 1.5-inch 13 MHP 2-inch

psi @ 70 °F

(kPa @ 21 °C)

450 (3 103)

500 (3 448)

600 (4 138)

550 (3 793)

1500 (10 345)

1000 (6 896)

psi @ 250 °F

(kPa @ 121 °C)

250 (1 724)

250 (1 724)

300 (2 069)

275 (1 896)

1200 (8 276)

800 (5 517)

Recommended Torque

25in-lb (2.8 N•m)

25in-lb (2.8 N•m)

25in-lb (2.8 N•m)

25in-lb (2.8 N•m)

20 ft-lb (27 N•m)

20 ft-lb (27 N•m)

2-4

Image 12
Contents Reference Manual Page Rosemount 4500 Hygienic Pressure Transmitter Page Table of Contents Operation Maintenance SectionUsing this Manual Section IntroductionService Support Section Installation Overview Safety MessagesConsiderations GeneralEnvironmental Hart Installation Flowchart Installation Procedures Mount the TransmitterSet Switches LCD Switches LOI SwitchesConfigure Alarm Direction AMSConnect Wiring and Power Up Hart Terminal BlocksInstalling the LCD Meter GroundingSection Configuration Setting the Loop to Manual Commissioning on the Bench with HartWiring Diagrams Hart Communicator Menu TreeFast Key Sequence Function Hart Fast Key SequenceReview Configuration Data Sensor Temperature Check OutputProcess Variables Basic Setup Set Process Variable UnitsRerange Fast Keys 3, 1 Damping LCD DisplayDetailed Setup Failure Mode Alarm and SaturationAlarm and Saturation Level Configuration Alarm and Saturation Levels for Burst Mode Alarm and Saturation Values for Multidrop ModeAlarm Level Verification Process Alerts Scaled Variable Configuration Rosemount Re-mapping Sensor Temperature Unit Diagnostics ServiceTransmitter Test Loop Test Saving, Recalling, Cloning Configuration Data Advanced Functions for Hart ProtocolRosemount Burst Mode Multidrop Communication Changing a Transmitter Address Communicating with a Multidropped TransmitterPolling a Multidropped Transmitter Operation and Maintenance Overview Calibration for Hart ProtocolCalibration Overview Transmitter Data Flow with Calibration Options Calculate total probable error TPE Determining Calibration FrequencyChoosing a Trim Procedure Sensor Trim Zero Trim Full TrimRecall Factory Trim Recall Factory Trim- Sensor Trim Recall Factory Trim- Analog Output Analog Output Trim Digital-to-Analog TrimDigital-to-Analog Trim Using Other Scale Diagnostic Messages Fail ModuleNonpv Limit Stuck KEY Troubleshooting Symptom Corrective Actions Specifications Performance SpecificationsAppendix a Reference Data Functional Specifications 00809-0100-4027, Rev AA December Range and Sensor LimitsRosemount Physical Specifications Dimensional Drawings 11/2 inch Tri-Clamp ModuleInch Tri-Clamp Module Fractional Line Fitting Module Ordering Information Code Process Connection StyleAppendix B Product Certificates Hazardous Locations Certifications North American CertificationsRosemount Rosemount Index Index-2 Page ¢00809-0100-4027 ¤