Emerson 4500 manual Ordering Information, Code Process Connection Style

Page 62

Rosemount 4500

Reference Manual

00809-0100-4027, Rev AA December 2005

ORDERING

INFORMATION

Model

Transmitter Type

 

 

4500

Hygienic Pressure Transmitter

Code

Measurement Type

 

 

GGauge

A Absolute

Code

Pressure Range

 

 

Gauge

Absolute

 

 

 

1

-14.7 to 30 psi

0 to 30 psia

2

-14.7 to 150 psi

0 to 150 psia

 

 

 

Code

Wetted Materials

 

 

 

 

2316L SST

3Hastelloy C-276

Code

Process Connection Style

 

 

C11

1-1/2inch Tri-Clamp Connection

C12

2 inch Tri-Clamp Connection

 

 

C13

1-1/2inch Fractional Line Fitting Connection

Code

Oil Fill

 

 

A

Neobee M-20

Code

Transmitter Output

 

 

A

4-20 mA with Digital Signal Based on HART protocol

Code

Cable Entry

 

 

2A

Cable Gland

Code

Options

 

 

 

Surface Finish

F1

Electro polished to 10 μ-inch Ra

 

 

 

Software Configuration

C1

Custom Software Configuration (CDS required with order)

 

 

 

Alarm Limits

C6

Custom Alarm & Saturation Signal Levels, High Alarm

 

 

C7

Custom Alarm & Saturation Signal Levels, Low Alarm

 

Hardware Adjustments

 

 

D1

Zero & Span Adjustments

 

Digital Display

 

 

M5

LCD Display

 

Calibration Data Certificate

 

 

Q4

Calibration data certificate consistent with ISO 10474 2.1 or EN 10204 2.1

QP

Calibration Certificate and Tamper Evident Seal

 

 

 

Material Traceability Certification

Q8

Material traceability certification per EN 10204 3.1.B

 

 

 

Surface Finish Certification

Q16

Surface Finish Certification

 

 

Code

Product Certifications

 

 

I1

ATEX Intrinsic Safety

 

 

I5

FM Approvals Intrinsically Safe

I6

CSA Intrinsically Safe

 

 

N1

ATEX Type n

 

 

Typical Model Number: 4500 G 2 2 C12 A A 2A

A-8

Image 62
Contents Reference Manual Page Rosemount 4500 Hygienic Pressure Transmitter Page Table of Contents Operation Maintenance SectionUsing this Manual Section IntroductionService Support Section Installation Overview Safety MessagesEnvironmental ConsiderationsGeneral Hart Installation Flowchart Installation Procedures Mount the TransmitterSet Switches LCD Switches LOI SwitchesConfigure Alarm Direction AMSConnect Wiring and Power Up Hart Terminal BlocksInstalling the LCD Meter GroundingSection Configuration Setting the Loop to Manual Commissioning on the Bench with HartWiring Diagrams Hart Communicator Menu TreeFast Key Sequence Function Hart Fast Key SequenceReview Configuration Data Process Variables Sensor TemperatureCheck Output Rerange Basic SetupSet Process Variable Units Fast Keys 3, 1 Damping LCD DisplayDetailed Setup Failure Mode Alarm and SaturationAlarm and Saturation Level Configuration Alarm and Saturation Levels for Burst Mode Alarm and Saturation Values for Multidrop ModeAlarm Level Verification Process Alerts Scaled Variable Configuration Rosemount Re-mapping Transmitter Test Sensor Temperature UnitDiagnostics Service Loop Test Saving, Recalling, Cloning Configuration Data Advanced Functions for Hart ProtocolRosemount Burst Mode Multidrop Communication Polling a Multidropped Transmitter Changing a Transmitter AddressCommunicating with a Multidropped Transmitter Operation and Maintenance Overview Calibration for Hart ProtocolCalibration Overview Transmitter Data Flow with Calibration Options Calculate total probable error TPE Determining Calibration FrequencyChoosing a Trim Procedure Sensor Trim Zero Trim Full TrimRecall Factory Trim Recall Factory Trim- Sensor Trim Recall Factory Trim- Analog Output Analog Output Trim Digital-to-Analog TrimDigital-to-Analog Trim Using Other Scale Diagnostic Messages Fail ModuleNonpv Limit Stuck KEY Troubleshooting Symptom Corrective Actions Appendix a Reference Data SpecificationsPerformance Specifications Functional Specifications 00809-0100-4027, Rev AA December Range and Sensor LimitsRosemount Physical Specifications Dimensional Drawings 11/2 inch Tri-Clamp ModuleInch Tri-Clamp Module Fractional Line Fitting Module Ordering Information Code Process Connection StyleAppendix B Product Certificates Hazardous Locations Certifications North American CertificationsRosemount Rosemount Index Index-2 Page ¢00809-0100-4027 ¤