Yamaha PJP-100H Making a Call, Calling another unit by specifying an IP address, 192.168.100.20

Page 19

Making a Call

Calling another unit by specifying an IP address

Follow the procedure below to specify an IP address to call another unit. Both PJP units should be turned on and connected to the network with a LAN cable.

/ Numeric keys

LAN

1

2

3

 

 

4

5

6

 

OUT

 

AUDIO

7

8

9

 

 

 

 

 

 

 

IN

 

0

 

 

 

 

MIC MUTE

 

VOL

IN 12V

 

 

DC

 

 

 

 

 

 

 

 

 

MIC MUTE VOL +/–

 

 

 

 

 

 

1 Press

repeatedly until the initial display

 

3 Press

.

 

appears.

 

 

The calling display appears.

000.000.000.000

IP: 192.168.0.10

^

 

 

192.168.100.20

Menu :Address

[ ]

:Cancel

[#]

2Use the numeric keys to enter the IP address of the destination unit.

000.000.000.000

^

[] [#]

If you make an entry mistake, press (*) or

(#)to move the cursor below the number you want to correct, and use the numeric keys to enter the correct figure.

BASIC CALL OPERATIONS

English

15

Image 19
Contents IP audio conference system Important Safty Instractions FCC Information for US customers Iii Contents Arrayed microphones and speakers for high audio quality FeaturesSettings from the PC Audio conference through networksAbout this manual Supplied AccessoriesAbout trademarks Top panel Controls and FunctionsAudio OUT terminal Right side panelDC in 12V terminal Audio in terminalArrayed speakers Bottom panel OtherSerial label Serial terminalMenu Address 192.168.100.200Display LAN cable Preparation ProcedureTo configure the settings from a PC To use this unit with a SIP serverStandby mode Connecting this unitTo exit the standby mode and switch this unit on again To check if the correct network information is obtained Registering the network settings of this unitIf the IP address display is ???.???.???.??? Obtaining the IP address automaticallyIP ???.???.???.??? Menu Address Menu Settings Call History OnlineSettings Network Settings Sound Settings General Settings Network Settings IP Address Subnet Mask Default GatewayIP Adress 192.168.100.200 Enable DisableSubnet Mask 255.255.255.000 Press or to select 4. DNS Server, Then press Default Gateway 000.000.000.000Press or to select 3. Default Gateway Then press DNS Server 000.000.000.000About installation environment Installing this unit in the conference roomTake the positions of the talkers in consideration 192.168.100.20 Menu Address CancelMaking a Call Calling another unit by specifying an IP addressTo make a call involving multiple Locations 192.168.0.10To mute the microphone Online 192.168.0.20 Calling another unit using the address bookAddress Book Headquarter Branch a Branch B Calling another unit in online statusPress or to select 2. Call History, Then press Online 192.168.0.20 CancelCalling another unit using the call history Call History Headquarter Branch aCall History Headquater Branch a CancelTo deny the call Answering a CallWhile having an incoming call, press To call another location during a call Carry out one of the following procedure during a callCarry out the procedure in Answering a Call Talking with Multiple Locations192.168.100.20 192.168.100.30 192.168.100.40 Menu Address When Speaker Mode is set to DivideWhen Speaker Mode is other than Divide 192.168.100.20 192.168.100.30 Menu AddressPress during call Change Location 192.168.100.20 192.168.100.30 Menu AddressPress or to select 4. Change location Then press Configuring settings using the keys on this unit Configuring SettingsPress or to select the menu category Then press Change the parameter Configuring settings using the web menuTo return to the previous menu without saving the setting To confirm the setting, pressConfiguring network settings Setting Menu ListManaging address book information Configuring the SIP server setting Configuring the Dhcp server settingsConfiguring the connection mode Configuring the NAT traversal settingSelecting the audio pickup area Microphone mode Configuring sound settingsConfiguring the speaker mode Using the web menuConfiguring the external input/output Setting Configuring the room sizeConfiguring the audio connection function Configuring general settings Restoring the factory settings Setting the passwordStoring the call history Registering a new address Editing Address BookEditing an existing address Deleting an address Click Submit Using the SIP ServerRegistering the SIP server information Web menu, click SIP ServerInitial display Display in SIP server operationTokyohq@sales.yama 2006.05 09 48 Menu Address Calling another unit by dialing the userWeb menu, click Sntp Server Setting Date and TimeManaging the Call History Contents of call history fileViewing the call history file Confirming the System Log Message of This Unit syslog Web menu, click Syslog SettingMaximum number of locations by Cascade connection What is cascade connection ?Configure the settings Cascade clients Configure the setting of the cascade serverDisplay in cascade connection Software Licensing Agreement Updating the FirmwareWhen the firmware update is complete Settings General Settings Restore Settings Firmware UpdateFirmware Update ver. DT1.12-V1.6x Yes 2. No Firmware update process takes a few minutes to completeUpdating the firmware manually Press To cancel the firmware updateQ1 LED indicators do not light up TroubleshootingWeb menu cannot be opened Q2 Web menu setting is not availableCall cannot be originated Q3 Call is impossibleAudio is interrupted Q4 Other problemsTo cancel resetting in the middle Resetting the UnitRestore Settings Yes 2. No Resetting using the keys on this unitWeb menu, click Restore Factory Settings Resetting using the web menuClick Restore Factory Settings Click Save Obtaining the Setting Information for Support on this UnitObtaining the audio characteristic information Click Download Setting Information in the web menuSpecifications Page All rights reserved