Using the SIP Server
Registering the SIP server information
When this unit is used in an environment with a SIP server, the address of the SIP server to be referenced by this unit and the SIP address of this unit should be registered. If password authentication is required for accessing the desired SIP server, it is also necessary to enter the password. Consult your system administrator for details.
Note
The settings described in this section are not required if this unit is used in an environment without SIP server.
1In the web menu, click “SIP Server”.
The “SIP Server” window appears.
2In the “SIP Server” field, click “Enable”.
3In the “SIP Server Name” field, enter the name or IP address of the SIP server.
4If password authentication is required for accessing the desired SIP server, enter the authentication password for the SIP server in the “SIP URI Password” field.
5In the “SIP URI” field, enter the SIP address to be set to this unit.
Enter the SIP address in the format “sip:(sip address)”.
Example: sip:sipuser@yamaha.co.jp
6Click “Submit”.
The setting is registered and the top window of the web menu reappears.
Notes on SIP server operation
•To connect a call using the SIP server, the SIP address of this unit should be registered in the SIP server.
•It is not possible to establish a connection between a PJP unit that uses the SIP address and a PJP unit that uses the IP address.
•If the SIP server is installed outside the LAN, it is required to use the NAT transversal function (page 27) of this unit.
Branch A | Branch B |
Router | Router |
| Router |
SIP server
Headquarter
In this case, the following conditions are required.
•The router to which the PJP is connected supports the UPnP function.
•A global IP address is assigned to the WAN on the router side.
Note
When a SIP call is connected using the NAT transversal function, it is not possible to install multiple PJP units in a single segment and connect a call between them.