TROUBLESHOOTING |
|
The only viable solution is to refrain for using
15.16 POPUP WARNING
Problem:
An xnmevent popup warns that only 10 popups can be generated at a time.
Solution:
The /usr/OV/appdefaults/XNm resource file sets the xnmevents.maxDisplayMsgs to ten (10). This can be modified if desired. The limit is set to this value so all the system resources are not used up by popups when no one is around to clear them.
15.17 MULTINODE TRAFFIC NOT SEEN CORRECTLY ON MSM SESSIONS
Problem:
MultiSite Monitor fails to display originating node traffic on NIM (site) column and destination node traffic on Device (node) column.
Solution:
Sometimes the CEC/IMC CAM card gets confused, especially if it has been moved between card cages. To clear the problem, clear the CAM’s NOV RAM using the following procedure (For CEC/IMC information, refer to
1.Remove the CAM card and reset the DIP switches so the card will function as another device, such as a CIM.
2.Reinsert the card into the card cage. This will clear the NOV RAM.
3.Remove the card and reconfigure the DIP swiches so card card will function as a CAM.
4.Reinsert the card.
77