Emerson 400501-08 manual Input Word Select Data Pointer, Code Description

Page 26

Epsilon Ei DeviceNet Drive Reference Manual

Input Word Select Data Pointer

The Input Word Select Data Pointer may be used when a polled connection is established between the Ei-DN and the DeviceNet Master. Using the Input Data Pointer Bits, 32-bit parameters may be read from the Ei-DN by the PLC. Entering the code into the input select data pointer will place the corresponding parameter value within the two high words of the 4 word polled data packet. The Input Word Data Select Data Pointer is set by the master in word 1 of the Master Send Data.

Code

Description

0x00

No Operation

 

 

0x01

Position Feedback

 

 

0x02

Position Command

 

 

0x03

Velocity Feedback

 

 

0x04

Command Velocity

 

 

0x05

Reserved

 

 

0x06

Torque Command

 

 

0x07

Index Position

 

 

0x08

Index Velocity

 

 

0x09

Index Accel

 

 

0x0A

Index Decel

 

 

0x0B - 0x1D

Reserved

 

 

0x1E

Fault Status Bitmap

 

 

0x1F

Reserved

 

 

14

Image 26
Contents Reference Manual Page Epsilon Ei DeviceNet Drive Reference Manual Page Website and Email Customer Support952 Technical Support 952 995-8033 or 800Document Conventions Training Services 952 995-8000 or 800Customer Service Sales 952 995-8000 or 800 Application Engineering 952 995-8000 or 800This Represents General Warning Safety InstructionsReference Materials Qualified PersonSetup, Commissioning and Maintenance Safety ConsiderationsSafety Precautions EnclosureSafety of Machinery General warningTable of Contents Drive Parameters Network Configuration Quick StartExplicit Messaging Quick Start Appendix Glossary IndexIntroduction PurposeDeviceNet Overview DeviceNet Communications LinkDeviceNet Messaging and Communications Master/Slave RelationshipMaster/Slave Relationship DeviceNet Hardware Components InstallationMechanical Installation CablesPower Supply Requirements Electrical InstallationConnectors Physical Connections to the DeviceNet NetworkInstallation Epsilon Ei DeviceNet Drive Reference Manual DeviceNet Tab Connection TypesSoftware Interface Polled I/O Connections Implicit MessagingBaud Rate Master Receive and Master Send Assembly Block SelectionsMacID Index Select Predefined Index Sel PredefConfiguring the DeviceNet Network Index Select User Defined Index Sel UserDefIndex Type Position ControlNo Operation CCWInput Word Select Data Pointer Code DescriptionOutput Word Select Data Pointer Command Assembly Code Response Assembly CodesConfiguring the DeviceNet Network Host Mode Enable Ei-DN Input Processing LogicCounters DeviceNet Online TabInformation Network Status LED StatusEstablished Connections Module Status LEDInput and Output Tab DeviceNet BitsFaults and Diagnostic Display Ei-DN Modbus Address DN Allocation Choice Connections EstablishedDN Allocation Master MacID DN Bus Off Counter DN Bus Off Fault CountDN Baud Rate DN Bus Off InterruptDN Device Type DN Comm Time-out Fault CountDN Duplicate MacID Fault Count DN FAB Master Receive BlockDN MacID DN Host ModeDN FAB Master Send Block DN Master Send Bitmap DN Master Receive BitmapDN Master Receive FAB Type DN Master Send FAB Type DN Module StatusDN Network Status DN Status Major Recoverable FaultDN Status Major Unrecoverable Fault DN Receive CounterDN Transmit Counter DN Status Minor Recoverable FaultDN Status Minor Unrecoverable Fault DN Vendor IDModule Status LED Accessing the EDS FileHardware Interface Viewing and Changing the Baud Rate and MacID Setting the Baud Rate and MacID Externally One TouchNetwork Status LED Display Value Baud Epsilon Ei DeviceNet Drive Reference Manual Network Configuration Quick Start EquipmentPolled I/O Setup Example #1 Index SelPredefNetwork Configuration Quick Start Example #2 Index Sel Userdef DN Setup / Index Sel Userdef Inputs Tab Outputs Tab Example #3 Index Type DN Setup / Index Type Output Word Select Input Word Select Example #4 Position Control Dn Setup / Position Control Network Configuration Quick Start Master Configuration RS Networx ConfigurationScanlist Tab Input Tab Output Tab Epsilon Ei DeviceNet Drive Reference Manual How to Send Explicit Messages Explicit Messaging Quick StartExecute Explicit Messaging Examples Description of N10 Integer FileExample 1 Read Index 0 Velocity Explanation of PLC ProgramExamples Example 2 Write Index 1 Velocity Integer File N11 High Byte Low ByteInterger File N10 High Byte Low Byte Explicit Messaging Quick Start Epsilon Ei DeviceNet Drive Reference Manual Name Drive ParametersBy Name DeviceNet Data TypeUdint Drive Parameters ProductID.Option1IDFunctionModule By DeviceNet Class 0x01 DeviceNet.DeviceNetIdentityObject.DeviceType 104 0x68 See Note 0x09 Index.Instance#.RegistrationOffset 109 0x6D 0x01 0x04 Position.FollowingError 0x01 0x0D Status.TorqueFeedback Epsilon Ei DeviceNet Drive Reference Manual Appendix Index Select PredefinedMaster Receive Assembly Block Index Sel User Def Index Select User DefinedIndex Type Position Control CCWGlossary Explicit Message Drop LineEpsilon Drive Explicit Messaging ConnectionsLink Consumer Object One touch ConfigurationConnections Link Producer ObjectUcmm Index Epsilon Ei DeviceNet Drive Reference Manual Index Epsilon Ei DeviceNet Drive Reference Manual