Epsilon Ei DeviceNet Drive Reference Manual
5.Install the .eds file in the Master Configuration software (RsNetworx, Wonderware, etc.).
6.Download a configuration for 8 polled input bytes and 8 polled output bytes to be transferred to/from the
7.Use ladder logic commands to initiate explicit messaging commands over DeviceNet.
Polled I/O Setup
The following examples assume that the user is familiar with and can set up the Ei using the Epsilon Ei Reference Manual (P/N
Example #1: Index Sel(Predef)
This sample procedure for the Index Sel(Predef) assembly block will run preconfigured Index 1 and 2 and Jog while reading back Torque Command and Command Velocity respectively.
1.Start a new
2.Configure Index 0 as a Incremental Index, Index Count of 1, Distance of 20 revs at a Velocity of 1000 RPM, both Acceleration and Deceleration set to 1000 ms/Krevs/m and a Dwell Time of 0.
3.Enter the DeviceNet setup and set the MacID to 1 and the Baud Rate to 125K. Select the Index Sel (Predef) for both Master Send Assembly Block and Master Receive Assembly Block.
36