Sipura Technology SPA-2000 manual Installation Overview, Software Configuration, Firmware Upgrade

Page 6

Unknown DHCP Error

SLOW

Silent

Note: The Link LED will blink on transmit and receive (TX/RX) of packets. The LED will display solid off if no link is available. The LED will display solid on if link is up but no TX/RX activity is present.

Important Warning: Do not disrupt the power to the SPA-2000 while the Status LED is blinking FAST.

2. Installation Overview

Please check to make sure that you have the following package contents:

1.Sipura Phone Adapter Unit

2.Ethernet Cable

3.SPA-2000 QuickGuide

4.5 Volt Power Adapter

You will also need:

1.One or Two Analog Touch Tone Telephones (or Fax Machine)

2.Access to an IP Network via an Ethernet Connection

Please observe the following steps to install the SPA-2000.

From the Left Side of the SPA-2000:

1.Insert a standard RJ-45 Ethernet cable (included) into the LAN port.

2.Insert the power adapter cable into the 5V power adapter cable receptacle. Ensure that the power adapter jack is snugly attached to the SPA.

From the Right Side of the SPA-2000:

1.Insert a standard RJ-11 telephone cable into the Phone 1 port.

2.Connect the other end of the cable to an analog telephone or fax machine.

3.Insert a standard RJ-11 telephone cable into the Phone 2 port (Optional).

4.Connect the other end of the cable to an analog telephone or fax machine. Note: Do not connect RJ-11 telephone cable from the SPA to the wall jack

to prevent any chance of connection to the circuit switched telco network.

You may now insert the plug end of the power adapter into a live power outlet which will power up the SPA-2000.

3. Software Configuration

3.1.1.1.Firmware Upgrade

The SPA-2000 is firmware upgradeable via TFTP or via an executable PC program obtained from Sipura Technology or an authorized distributor/reseller of Sipura Technology products.

Please contact the company from whom you purchased your SPA-2000 for access to Sipura Technology firmware upgrades.

Firmware Upgrade via TFTP:

Firmware designed for TFTP upgrades are released as single binary files, which contain all the modules pertaining to any one release version. By convention, the firmware loads are named with the extension “.bin” (e.g. spa.bin)

The SPA-2000 can be configured to upgrade to a specific version, possibly staging through intermediate releases, if necessary. This process can be automated for a pool of devices through configuration profile parameters.

© 2003 Sipura Technology, Inc

Proprietary (See Copyright Notice on Page 2)

6

Image 6
Contents Sipura Technology, Inc DecemberDisclaimer Please Read Use of Proprietary Information and Copyright NoticeTable of Contents Sipura Technology, Inc SPA-2000 User GuideProduct Description SPA-2000 Hardware OverviewDefault Handset Blink Behavior Rate Status LED DescriptionStatus Description Firmware Upgrade Installation OverviewSoftware Configuration Firmware Upgrade via TftpFirmware Upgrade via PC Utility Program IVR InterfaceIVR Conventions IVR Action IVR Menu Choice Parameters SPA-2000 Interactive Voice Response IVR MenuExample 100110 Requires Password101 111Administration Privileges SPA Web InterfaceWeb Interface Conventions Basic and Advanced Views SPA-2000 Web Page Configuration Default Values SPA-2000 Information Web Page Advanced Admin ViewSPA-2000 System Configuration Web Page Advanced Admin View SPA-2000 SIP Configuration Web Page Advanced Admin View Sipura Technology, Inc Proprietary See Copyright Notice on SPA-2000 Regional Configuration Web Page Advanced Admin View SPA-2000 Line 1 Configuration Web Page Line 2 Is Identical SPA-2000 User 1 Configuration Web Page User 2 Is Identical Configuration Parameters System ParametersProvisioning Parameters Upgrade Parameters Protocol ParametersSIP T1 SDP Audio Codec Names Parameter Name Description Default NAT Support Parameter Name Description DefaultUser Account Information Parameter Name Description Default Line 1 and Line 2 ParametersSupplementary Services Enable Audio Settings Parameter Name Description Default Dial Plan Parameter Name Description Default Polarity Settings Parameter Name Description DefaultUser 1 and User 2 Parameters Speed Dial Settings Parameter Name Description Default Call Progress Tones Parameter Name Description Default Regional ParametersRing and CWT Cadence Parameter Name Description Default Control Timer Values sec Parameter Name Description Default Page System Status Miscellaneous Parameters Parameter Name Description DefaultCall Statistics Reporting Line 1/2 StatusUser Guidelines Call 1/2 StatusOriginating a Phone Call Basic ServicesEnhanced Services Receiving a Phone CallCalling Line Identification Presentation Clip Call Waiting To block Caller ID on all outbound calls, doFollowing Disable or Cancel Call Waiting Call-Waiting with Caller ID Voice MailAttendant Call Transfer Unattended or Blind Call TransferCall Hold Three-Way CallingThree-Way Ad-Hoc Conference Calling Call ReturnAutomatic Call Back Call FWD UnconditionalCall FWD Busy Call FWD No Answer Anonymous Call Blocking Distinctive / Priority Ringing and Call Waiting ToneSpeed Calling Up to Eight 8 Numbers or IP Addresses Sipura Technology, Inc Proprietary See Copyright Notice on Where to Get Support Appendix I Dial Plan Administration Dial PlanPage Xxx 4911 1 2-9xx