Samsung Version 2.1 manual Communication Environment Setup for TCP/IP connections

Page 21

Link SettingsOfficeServ Link Version 2.1 User Guide

--------------------------------------------------------------------------------------------------------------------------------------------------------------------

ySIM connection mode: Uses SIM Module to connect the PBX system.

ySerial Cable connection mode: Connects a serial cable to the PBX system directly.

yTCP/IP connection mode: Uses LAN-based TCP/IP to connect

These three connections are basically divided into Serial communications and TCP/IP communications. Because both methods need environment settings different from each other, the appropriate communication parameter dialog box becomes active once the primary communications method is selected.

Communication environment setup for SIM / Serial cable connections

This entry allows you to change environment settings for serial communications. The environment settings for serial communications are as follows:

yCOM Port: Receives the COM port No. of computer. The Link software uses the specified COM port No. to set up the channel of serial communications to connect the telephone system.

yBaud Rate: Receives the value of serial communications. Your specification of this value depends on the baud rate of system. By default, the value is defined as 9600 bps. However, as for iDCS 500 / OfficeServ, you have to use the primary speed of serial communications as 19200 bps. This value shall conform to the primary speed of PBX system.

Note

Primary speed of serial communications for each telephone system

 

• DCS 180: SIM Type, 9600 BPS

 

• SDX COMPACT: SIM / Serial Type, 19200 BPS

 

• iDCS 500/OfficrServ: Serial, 19200 BPS

 

Each system has a function of changing the baud rate. For the setting related with your installed

 

system, contact an Authorised Samsung Reseller.

 

 

yData Size: A value of 8 bits is used by default. This value shall coincide with that of communication environment of telephone system. Usually, this value is not changed.

yStop Bits: A value of 1 bit is used by default. This value shall coincide with that of communication environment of telephone system. Usually, this value is not changed.

Communication Environment Setup for TCP/IP connections

Some Samsung telephone systems support the LAN-based TCP/IP communications. The environment settings for TCP/IP connections are as follows:

yIP address: Receives the IP address of telephone system working in TCP/IP. (See the MMC 830 settings of Key telephone system.)

yPort No.: Receives the port No. waiting for a connection request from the Link. By default, this value is set to 5002. Usually, this value is not changed.

Note

TCP/IP connection is the preferred method of connection for iDCS and OfficeServ Systems.

 

The other methods are retained for compatibility with previous systems.

 

 

© SAMSUNG Electronics Co., Ltd.

Page 21

Image 21
Contents User Guide OfficeServ Link Conventions About This ManualPage Table of contents OfficeServ Link Version 2.1 User Guide Overview of OfficeServ Link IntroductionPage Preparation for installing Link Installation of LinkComputer System Requirements DCS Key Telephone RequirementsLink Configuration EnvironmentInstallation System Administration RequirementsPage Page Page Page Post Installation Installing the Link LicenseChecking the registered program group Executing OfficeServ Link OfficeServ Link SettingsDescription of Link Main Window Configuration of Link Main WindowStatus Bar Link Status bar informationConnection mode to telephone system Communication Environment SetupIDCS 500/OfficrServ Serial, 19200 BPS Communication Environment Setup for TCP/IP connectionsStatus View of Ports in Use Example of TCP/IP connections Example of Environment SetupOption Settings Normal optionRestriction for the currently connected users in number Message Monitoring and Saving Option General message monitoring option settingsMessage Auto Clear Option Automatic connection to PBX system at Link startupPassword Protection Option SMDR/ UCD message monitoring option settingsSmdr / UCD Message Exteranl Send Options OfficeServ Call+ Function Support OptionLink State Message Display Option Switch Link Recovery Try Count Option Recovery Try Time Period OptionLink Display Language Option Page Page Check the configuration of the Phone System Using LinkConnecting to a telephone system Telephone settings for a serial Link connectionOfficeServ Link Version 2.1 User GuideMessage Monitoring Connection state of Link is indicated as , and the AVI 1st recovery try failed and wait 1 minute Selection of Disconnect button Disconnecting to the PBX system and userLink Operating State View Viewing Link state in Default modeUser-connected Link Case that a user is currently connectedRunning the Switch Message Monitor SCMonitor.exe Message MonitoringCall processing message monitoring program Environment Setup of Switch Message Monitor Program Environment SetupMain window of Switch Message Monitor Click on the Stop Monitoring button to stop monitoring Smdr / UCD Message Monitoring ProgramExecuting the Smdr / UCD Message Monitor Running the Smdr / UCD Message Monitor SUMonitor.exeConfiguration of window is as follows Main window of Smdr / UCD Message Monitor Message MonitoringOfficeServ Link Version 2.1 User Guide Installing Monitoring Program on other Computer Page Page Running the License Tools License RegistrationPaste the valid license key Installing the LicenseLink Shutdown Check How to check the License Status Page Samsung OfficeServ Link