Timer setting

-

Call

Normal/Priority/Urgent

10 to 600 (sec.), 0 (Unlimited)

Normal: 30 (sec.)

 

 

 

 

 

 

 

Priority: 90 (sec.)

 

 

 

 

 

 

 

Urgent: 0

 

 

 

 

 

 

 

(Unlimited)

 

 

Communication

In Local (Not available)

30 to 600 (sec.) (Not used for network

60 (sec.)

 

 

 

 

 

 

direct system)

 

 

 

 

Via IP

 

 

30 to 600 (sec.)

60 (sec.)

 

 

 

Telephone (Not available)

30 to 600 (sec.) (Not used for network

120 (sec.)

 

 

 

 

 

 

direct system)

 

 

 

Paging

-

 

 

30 to 600 (sec.)

60 (sec.)

 

 

Monitor

-

 

 

10 to 600 (sec.)

60 (sec.)

 

 

Scan monitor:

-

 

 

5 to 60 (sec.)

7 (sec.)

 

 

Switching

 

 

 

 

 

 

 

Contact output

External sound source 1

10 to 300 (sec.)

30 (sec.)

 

 

(Not available)

External sound source 2

10 to 300 (sec.)

30 (sec.)

 

 

Door release

-

 

 

0 to 300 (sec.), (0: Released while

10 (sec.)

 

 

 

 

 

 

holding the Door release button pressed.)

 

Remote site

-

Remote site master

Normal/Priority/Urgent

(Select one from the registered stations

-

pilot call setting

 

call

 

 

 

in your site for each of “Normal”, “Priority”

 

 

 

 

 

 

 

and “Urgent”.)

 

 

 

Remote site door call

Normal/Priority/Urgent

(Select up to 20 stations from the

-

 

 

 

 

 

 

registered master stations in your site for

 

 

 

 

 

 

 

each of “Normal”, “Priority” and “Urgent”.)

 

 

 

Remote site room

Normal/Priority/Urgent

(Select up to 20 stations from the

-

 

 

sub call (available

 

 

 

registered master stations in your site for

 

 

 

when the remote site

 

 

 

each of “Normal”, “Priority” and “Urgent”.)

 

 

 

is a standard (IP)

 

 

 

 

 

 

 

system that includes

 

 

 

 

 

 

 

room sub stations

 

 

 

 

 

 

 

(IS-RS).)

 

 

 

 

 

 

 

Remote site paging

Normal/Priority/Urgent/

(Select one from the registered zones in

-

 

 

 

Broadcast

 

your site for each of “Normal”, “Priority”,

 

 

 

 

 

 

 

“Urgent” and “Broadcast”.)

 

Video setting

-

Frame Rate

-

 

 

1/2/5/7.5/10/15 (fps)

15 (fps)

 

 

Quality

-

 

 

Low, Middle, High, Excellent

Excellent

Time and date

-

Set current time

Manual setting

 

Year: 2009 to 2099

(Internal time

setting

 

 

 

 

 

Month: 1 to 12

of the IP Host

 

 

 

 

 

 

Day: 1 to 31

unit)

 

 

 

 

 

 

Hour: 0 to 23

 

 

 

 

 

 

 

Minute: 0 to 59

 

 

 

 

 

 

 

Second: 0 to 59

 

 

 

 

Synchronized with PC

-

-

 

 

NTP

Synchronized with NTP server

ON/OFF

OFF

 

 

 

NTP server*1

 

IP address or domain name

-

 

 

 

NTP port number*1

 

1 to 65535

123

 

 

 

(UTC time zone*1)

 

-12 to +13 (h)

0

 

 

 

Hour difference*1

 

 

 

 

 

 

(UTC time zone*1)

 

-45/-30/0/+30/+45 (m)

0

 

 

 

Minute difference*1

 

 

 

 

 

 

Synchronize interval

1 to 240 (h)

24 (h)

 

 

Daylight savings time

-

 

 

ON/OFF

OFF

 

 

 

Starts*2

Month

 

JAN to DEC (M)

JAN

 

 

 

 

Day

(Week)

1st to 4th (W)/The last

1st

 

 

 

 

 

(Day)

Sunday to Saturday

Sunday

 

 

 

 

Hour

(Hour)

0 to 23 (h)

-

 

 

 

 

 

(Minute)

0 to 59 (m)

-

 

 

 

Ends*2

Month

 

JAN to DEC (M)

JAN

 

 

 

 

Day

(Week)

1st to 4th (W)/The last

1st

 

 

 

 

 

(Day)

Sunday to Saturday

Sunday

 

 

 

 

Hour

(Hour)

0 to 23 (h)

-

 

 

 

 

 

(Minute)

0 to 59 (m)

-

 

 

 

Hour difference*2

 

0 to 12 (h)

1

 

 

 

Minute difference*2

 

0/30/45 (m)

0

*1: Available only when [Synchronized with NTP server] is set to ON.

*2: Available only when [Daylight savings time] is set to ON.

6

Image 6
Contents Setting Manual Contents Purpose of the System Settings About this ManualManual configurations Setting List Title Sub title Sub item Setting range DefaultDT1/DT2 NTP Call Priority Go to P System Setting FlowFrom the chart below, then start the network settings by First selectFlow All units Static IP addresses are set For the IP host unitFor each IP client unit Started Setting the System Using the System Remote site connection settings ProcedureSystem requirements for PC When connecting a PC to the IP unit via a hub switchWhen connecting a PC to the IP unit directly Connect a PC to the IP unitPassword Enter aiphone Turn on the power to the IP unitLog in to the system by setting the following items Go to the nextSystem Setting Details Basic setting procedureClick Network setting Individual in the table Click Network setting Common in the tableRepeat to 5 to make settings to other IP units Close the windowRegistering zones System setting Zone registration RequiredRegistering IP units System setting IP unit registration Click IP unit registration in the table of contentsCheck the boxes for the IP units you want to register Collective setting Registering stations System setting Registering stationsHow to select multiple stations Other buttonsClick Advanced station settings in the table of contents Basic setting procedureMaking detailed settings to door stations When you have finished making all the detailed settingsSettings on Stations to be scan monitored window Making detailed settings to master stationsSettings on Other window About the priorityClick Close after you have finished selecting the stations Registering stations to zones System setting Zone settingCheck to select the target stations Click Registering daily transfer scheduleClick Transfer schedule setting in the table of contents Settings on Weekly schedule setting windowSettings on Individual schedule setting window Setting the timer Timer setting Settings on Remote site door call setting window Click Remote site pilot call setting in the tableSettings on Remote site master call setting window Settings on Remote site paging setting windowSetting time and date Time and date setting When uploading setting data Downloading/uploading setting data Setting fileWhen downloading setting data onto the PC Click Downloading setting data in the table of contentsMaintenance Setting Information Memo