2 Turn on the power to the IP unit.

*If the unit is connected to a switch or injector that has a PoE function, the power is being supplied. If a power supply unit is connected to the unit, turn on the power of the power supply unit.

*Turn on all the units constituting the system depending on the network setting method.

*The status LED of an IP video door station changes from red lighting to orange blinking.

(When the settings have correctly made, it changes to orange lighting.)

The status LED of an IP master station changes from red lighting to red blinking.

(When the settings have correctly made, it turns off.)

3 Start up the PC, and then open the browser window.

4 Enter the (static) IP address assigned to the IP unit to access the web browser for settings.

Default: https://192.168.0.40

192.168.0.40/

After selecting English as the target language, the login window of the web browser is displayed.

5 Log in to the system by setting the following items.

ID

Enter “aiphone”.

Password Enter “aiphone”.

Login

Click Login to display the setting window.

*When you log in for the first time, the [Registration] window appears. Register your system as needed.

(When registering your system, if you use an IS-SOFT in the system, enter the license key of the IS-SOFT.)

NOTE:

Be sure not to log in to the system more than once at the same time by opening multiple browser windows on the PC.

Go to the next page.

14

Image 14
Contents Setting Manual Contents Manual configurations Purpose of the System SettingsAbout this Manual Setting List Title Sub title Sub item Setting range DefaultDT1/DT2 NTP Call Priority Go to P System Setting FlowFrom the chart below, then start the network settings by First selectFlow For each IP client unit All units Static IP addresses are setFor the IP host unit Started Setting the System Using the System Remote site connection settings ProcedureSystem requirements for PC When connecting a PC to the IP unit via a hub switchWhen connecting a PC to the IP unit directly Connect a PC to the IP unitPassword Enter aiphone Turn on the power to the IP unitLog in to the system by setting the following items Go to the nextSystem Setting Details Basic setting procedureClick Network setting Individual in the table Click Network setting Common in the tableRepeat to 5 to make settings to other IP units Close the windowRegistering zones System setting Zone registration RequiredCheck the boxes for the IP units you want to register Registering IP units System setting IP unit registrationClick IP unit registration in the table of contents Collective setting Registering stations System setting Registering stationsHow to select multiple stations Other buttonsClick Advanced station settings in the table of contents Basic setting procedureMaking detailed settings to door stations When you have finished making all the detailed settingsSettings on Stations to be scan monitored window Making detailed settings to master stationsSettings on Other window About the priorityClick Close after you have finished selecting the stations Registering stations to zones System setting Zone settingCheck to select the target stations Click Registering daily transfer scheduleSettings on Individual schedule setting window Click Transfer schedule setting in the table of contentsSettings on Weekly schedule setting window Setting the timer Timer setting Settings on Remote site door call setting window Click Remote site pilot call setting in the tableSettings on Remote site master call setting window Settings on Remote site paging setting windowSetting time and date Time and date setting When uploading setting data Downloading/uploading setting data Setting fileWhen downloading setting data onto the PC Click Downloading setting data in the table of contentsMaintenance Setting Information Memo