Lincoln Electric SVM107-B service manual Welding Sparks can cause fire or explosion, Iii

Page 4

iii

iii

SAFETY

Return to Master TOC

Return to Master TOC

Return to Master TOC

WELDING SPARKS can cause fire or explosion.

6.a. Remove fire hazards from the welding area. If this is not possible, cover them to prevent the welding sparks from starting a fire. Remember that welding sparks and hot

materials from welding can easily go through small cracks and openings to adjacent areas. Avoid welding near hydraulic lines. Have a fire extinguisher readily available.

6.b. Where compressed gases are to be used at the job site, special precautions should be used to prevent hazardous situations. Refer to “Safety in Welding and Cutting” (ANSI Standard Z49.1) and the operating information for the equipment being used.

6.c. When not welding, make certain no part of the electrode circuit is touching the work or ground. Accidental contact can cause overheating and create a fire hazard.

6.d. Do not heat, cut or weld tanks, drums or containers until the proper steps have been taken to insure that such procedures will not cause flammable or toxic vapors from substances inside. They can cause an explosion even though they have been “cleaned”. For information, purchase “Recommended Safe Practices for the Preparation for Welding and Cutting of Containers and Piping That Have Held Hazardous Substances”, AWS F4.1 from the American Welding Society (see address above).

6.e. Vent hollow castings or containers before heating, cutting or welding. They may explode.

6.f. Sparks and spatter are thrown from the welding arc. Wear oil free protective garments such as leather gloves, heavy shirt, cuffless trousers, high shoes and a cap over your hair. Wear ear plugs when welding out of position or in confined places. Always wear safety glasses with side shields when in a welding area.

6.g. Connect the work cable to the work as close to the welding area as practical. Work cables connected to the building framework or other locations away from the welding area increase the possibility of the welding current passing through lifting chains, crane cables or other alternate circuits. This can create fire hazards or overheat lifting chains or cables until they fail.

6.h. Also see item 1.c.

CYLINDER may explode if damaged.

7.a. Use only compressed gas cylinders

containing the correct shielding gas for the process used and properly operating regulators designed for the gas and

pressure used. All hoses, fittings, etc. should be suitable for the application and maintained in good condition.

7.b. Always keep cylinders in an upright position securely chained to an undercarriage or fixed support.

7.c. Cylinders should be located:

Away from areas where they may be struck or subjected to physical damage.

A safe distance from arc welding or cutting operations and any other source of heat, sparks, or flame.

7.d. Never allow the electrode, electrode holder or any other electrically “hot” parts to touch a cylinder.

7.e. Keep your head and face away from the cylinder valve outlet when opening the cylinder valve.

7.f. Valve protection caps should always be in place and hand tight except when the cylinder is in use or connected for use.

7.g. Read and follow the instructions on compressed gas cylinders, associated equipment, and CGA publication P-l, “Precautions for Safe Handling of Compressed Gases in Cylinders,” available from the Compressed Gas Association 1235 Jefferson Davis Highway, Arlington, VA 22202.

FOR ELECTRICALLY powered equipment.

8.a. Turn off input power using the disconnect switch at the fuse box before working on the equipment.

8.b. Install equipment in accordance with the U.S. National Electrical Code, all local codes and the manufacturer’s recommendations.

8.c. Ground the equipment in accordance with the U.S. National Electrical Code and the manufacturer’s recommendations.

Return to Master TOC

Mar ‘95

Image 4
Contents Rangertm Safety Electric Shock can kill Welding Sparks can cause fire or explosion IiiPrécautions DE Sûreté Master Table of Contents for ALL Sections Table of Contents Installation Section Auxiliary Power Welding Output50 100 150 200 20 B50 100 150 200 250 300 350 Output Amps Installation Instructions Battery Connections OilAWG FuelAngle of Operation Connection of the LN-7 to the Ranger Welder OutputRanger Constant CurrentDuplex Receptacles Motor StartingElectrical Device USE with the Ranger Type Common Electrical Devices Possible ConcernsAuxiliary Power While Welding Standby Power ConnectionsConnection of Ranger 8 to Premises Wiring Figure A.1Ranger Table of Contents Operation Section AC/DC Stick Welding Constant Current DC Semiautomatic Wire Feed Welding Constant VoltageAC/DC TIG Welding Constant Current Control Switch Provides a fine welding current adjustment withinRange Switch settings in the STICK/TIG mode Welding voltage control with the Range switch setStarting/Shutdown Instructions Stopping the EngineStick Constant Current Welding Wire Feed Welding Processes Constant VoltageTIG Constant Current Welding Summary of Welding Processes Stick AutoSection C-1Section C-1 Accessories Recommended Equipment Ranger Table of Contents Maintenance Routine Maintenance Engine OIL ChangeEngine OIL Refill Capacities Kohler Onan HondaOIL Filter Change Engine Adjustments Engine Maintenance PartsPre-Cleaner Slip RingsFigure D.1 Major Component Locations Ranger Table of Contents Theory of Operation Section Theory of Operation Rotor Field Feedback and Auxiliary Power Weld WINDING, REACTOR, Range Switch Output BRIDGE, Choke Polarity SWITCH, and Output Terminals Ranger Table of Contents Trouble Shooting & Repair Section Troubleshooting & Repair HOW to USE Troubleshooting GuidePC board can be damaged by static electricity Static-SensitiveDevices Handle only atTroubleshooting Guide Output ProblemsObserve Safety Guidelines Detailed in the beginning of this manualTroubleshooting & Repair Troubleshooting & Repair Troubleshooting Guide Troubleshooting & Repair Engine Problems Troubleshooting & Repair Troubleshooting & Repair Welding Problems Ranger Test Description Rotor Voltage TestMaterials Needed Test Procedure Rotor Resistance Test Rotor Resistance Test Troubleshooting & Repair Ranger Auxiliary and Field Winding Test To test the 115 VAC winding To test the 230 VAC windingTo test the field winding Ranger Output Rectifier Bridge Test Output Rectifier Bridge Test Charging Circuit Test Charging Circuit Test Engine Throttle Adjustment Test Engine Throttle Adjustment Test Engine Throttle Adjustment Test Oscilloscope Method Normal Open Circuit Voltage Waveform 115 VAC Supply Scope SettingsHigh Idle no Load Output Control AT Maximum Typical DC Weld Output Waveform CV Mode Machine LoadedTypical DC Weld Output Waveform CC Mode Machine Loaded to 200 Amps AT 26 VDCTypical AC Weld Output Waveform Machine Loaded to 225 Amps AT 25 VDCAbnormal Open Circuit Weld Voltage Waveform CV Mode Abnormal Open Circuit DC Weld Voltage Waveform Normal Open Circuit Weld Voltage Waveform CV Mode Normal Open Circuit DC Weld Voltage Waveform CC Mode Normal Open Circuit AC Weld Voltage Waveform Ranger Brush Removal and Replacement DescriptionBrush Removal and Replacement ProcedureSlip Rings Figure F.10 Brush LEADS/BRUSHES Retained with Cable TIERanger Field Capacitor AND/OR Rectifier Bridge Removal Replacement Replacement Field Capacitor AND/OR Rectifier Bridge RemovalProcedure Rectifier Bridge Removal and Replacement Ranger Printed Circuit Board Removal Replacement Printed Circuit Board Removal and Replacement ProcedurePrinted Circuit Board Removal Ranger Output Rectifier Bridge Removal Replacement Remove the case top, then reinstall the fuel cap Output Rectifier Bridge RemovalSection TOC Ranger ENGINE/ROTOR Removal and Replacement InstructionsENGINE/ROTOR Removal Figure F.14 Component LOCATIONS, ENGINE/ROTOR RemovalEngine and Rotor Removal Procedure Rotor Removal Procedure Figure F.15 Engine and Rotor Removed from StatorReplacement KIT S20788 Reassembly ProcedureRetest After Repair Table of Contents Diagrams Section Dimension Dimension Print Ranger 8 Honda & Kohler RANGER8Diagrams Connection of Ranger 8 to LN-7 & K240 Contactor KITElectrical Diagrams Wiring Diagram Onan NON CSA ModelK1418-2 Ranger 8 Onan CSA Version Wiring Diagram Wiring Diagram Onan CSA ModelK1419-1 Ranger 8 Kohler Wiring Diagram Wiring Diagram Kohler NON CSA ModelK1419-2 Ranger 8 Kohler CSA Wiring Diagram Wiring Diagram Kohler CSA ModelK2160-1 Ranger 8 Honda CSA Wiring Diagram Schematic IDLER/CONTROL PC Board 16482PC Board Assembly IDLER/CONTROL SVM Error Reporting Form