TROUBLESHOOTING & REPAIR |
| ||||
Observe Safety Guidelines |
| TROUBLESHOOTING GUIDE | |||
detailed in the beginning of this manual. |
|
|
| ||
|
|
|
| ||
PROBLEMS | POSSIBLE AREAS OF | RECOMMENDED |
| ||
(SYMPTOMS) | MISADJUSTMENT(S) | COURSE OF ACTION |
| ||
|
|
|
|
| |
| OUTPUT PROBLEMS |
|
|
| |
No DC welding output. AC welding | 1. Make sure the Polarity Switch is | 1. Perform the Output Bridge Test. | |||
output and auxiliary power is nor- | in the proper position and is | 2. | Check the Choke (L1), | the | |
mal. | “seated” correctly. | ||||
| Polarity Switch (S2) and associ- | ||||
|
|
| |||
| 2. Make sure the electrode and |
| ated wires for loose or faulty | ||
| polarity are correct for the |
| connections. Check the choke | ||
| process being used. |
| winding for continuity and test | ||
|
|
| to be sure it is NOT grounded | ||
|
|
| the choke iron. |
| |
|
|
|
| ||
No AC welding output. DC welding | 1. Make sure the Polarity Switch is | 1. Check the operation of | the | ||
output and auxiliary power is nor- | in the proper position and is |
| Polarity Switch (S2). Also check | ||
mal. | “seated” correctly. |
| the associated wires for loose | ||
| 2. Make sure the electrode is cor- |
| or faulty connections. | See | |
|
| Wiring Diagram. |
| ||
| rect for the process being used. |
|
| ||
|
|
|
| ||
| 3. Make sure the welding cables | 2. | Check for continuity from lead | ||
|
| “S2” to lead “E” located in the | |||
| are not coiled or too long. |
| |||
|
| main stator. See Wiring Dia- | |||
|
|
| |||
|
|
| gram. |
| |
|
|
|
|
|