TROUBLESHOOTING & REPAIR |
|
|
| |||
Observe Safety Guidelines |
| TROUBLESHOOTING GUIDE | ||||
detailed in the beginning of this manual. |
|
|
|
|
| |
|
|
|
|
| ||
PROBLEMS | POSSIBLE AREAS OF | RECOMMENDED |
|
| ||
(SYMPTOMS) | MISADJUSTMENT(S) | COURSE OF ACTION |
| |||
|
|
|
|
|
|
|
| OUTPUT PROBLEMS |
|
|
|
|
|
Major Physical or Electrical | 1. Contact your local Lincoln | 1. Contact The Lincoln Electric | ||||
Damage is Evident. | Authorized Field Service |
| Service Dept. | |||
| Facility. |
| (WELD). |
|
|
|
|
|
|
| |||
No weld output and no auxiliary | 1. Check the brushes for wear and | 1. | Perform the Rotor Voltage Test. | |||
power. Engine runs normally. | proper contact to the rotor slip | 2. | Check | for the | presence of | |
| rings. | |||||
|
| 12VDC (at the pc board) from | ||||
|
|
| ||||
|
|
| lead #216 to frame ground. This | |||
|
|
| is the “flashing” voltage and is | |||
|
|
| present only when the Start, | |||
|
|
| Run, Stop switch S3 is in the | |||
|
|
| “Start” position. If the 12 VDC is | |||
|
|
| missing | check | the | leads, |
|
|
| switches and connections asso- | |||
|
|
| ciated with the lead #216. See | |||
|
|
| Wiring Diagram. |
|
| |
|
|
| Check for the presence of 12 | |||
|
|
| VDC (at the pc board) from lead | |||
|
|
| #224 to frame ground. This is | |||
|
|
| the supply voltage to the board | |||
|
|
| and is present when the engine | |||
|
|
| is running and the S3 switch is | |||
|
|
| in the “Run” position. If the | |||
|
|
| 12VDC is missing check the | |||
|
|
| leads, switches and connec- | |||
|
|
| tions associated with the lead | |||
|
|
| #224. See Wiring Diagram. | |||
|
| 3. If Rotor Voltage Test is normal, | ||||
|
|
| then | preform | the | Rotor |
|
|
| Resistance Test. |
|
| |
|
| 4. If the Rotor Voltage Test is NOT | ||||
|
|
| normal, | perform | the | Auxiliary |
|
|
| and Field Winding Voltage Test. | |||
|
|
| Then check the Field Diode | |||
|
|
| Bridge (D2) and the Field | |||
|
|
| Capacitor (C1). Replace if nec- | |||
|
|
| essary. If the Field Bridge and | |||
|
|
| Field Capacitor are good, then | |||
|
|
| the Printed Circuit Board may | |||
|
|
| be faulty. Replace. |
| ||
|
|
|
|
|
|
|
CAUTION
If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, con- tact the Lincoln Electric Service Department for electrical troubleshooting assistance before you proceed. Call