OPERATION | ||
|
|
|
OPERATIONAL FEATURES AND CONTROLS
POWER FEED™-10M SERIES SYSTEM CONFIGURA- TION
The specific system component function of the pc board will be configurable by dip switch or by software configuration tool. Dip switch configuration is as follows: Refer to DIP switch settings of figures below.
Notes:
1.Basic Power
POWER
UI/WD PCB - S25629 |
|
| O 1 2 | 3 | 4 | 5 | 6 | 7 8 | |||
N |
|
|
|
|
|
| |||||
(located on Wire Drive divider panel) |
|
|
|
|
|
| |||||
|
|
|
|
|
|
|
| ||||
WD only PCB - S25616 |
|
|
| O 1 2 3 | 4 | 5 6 7 8 | |||||
|
|
| |||||||||
(located on Wire Drive rear access door) | N |
|
|
|
|
|
CONTROLS (Refer to Figure B.2)
1. WIRE FEED SPEED (WFS) / AMP METER
This meter displays either the WFS or current value depending on the status of the machine. Located below the display are the text "WFS" and "Amps." An LED light is illuminated next to one of these in order to indicate the units of the value displayed in the meter.
•Prior to CV operation, the meter displays the desired pre- set WFS value.
•Prior to
•During Welding, the meter displays actual average amps, but may be configured to display actual WFS.
•After welding, the meter holds the actual current or WFS value for 5 seconds. During this time, the display is blink- ing to indicate that the machine is in the "Hold" period. Output adjustment while in the "Hold" period results in the "prior to operation" characteristics stated above.
•After the 5 second "Hold" period, the meter displays the set WFS (CV modes) or Amp (CC modes) value.
2.VOLT / TRIM METER
This meter displays either the voltage or trim value depending on the status of the machine. Located below the display are the text "Volts" and "Trim." An LED light is illuminated next to one of these in order to indicate the units of the value displayed in the meter.
CV Processes
•Prior to
•Prior to
•During Welding, the meter displays actual average volts.
•After welding, the meter holds the actual voltage value for 5 seconds. During this time, the display is blinking to indicate that the machine is in the "Hold" period. Output adjustment while in the "Hold" period results in the "prior to operation" characteristics stat- ed above.
•After the 5 second "Hold" period, the meter displays the set Voltage (GMAW, FCAW) or Trim
CC Processes
•The meter displays the status of the output.
•When output is enabled, the meter will display "ON."
•When there is no output, the meter will display "OFF."
FIGURE b.2
4
|
| 72 | ALUMINUM |
| IR PORT | 3/64" | |
|
|
| SETUP |
|
| PULSE 4043 Ar | |
5 | WELD MODE |
| START OPTIONS |
ARC CONTROL |
| END OPTIONS | |
| SET |
|