Lincoln Electric IM916 Parameter Definition Show Test Modes, View Diagnostics, View Fatal Logs

Page 30

 

b-12

 

OPERATION

b-12

 

 

 

 

 

 

 

 

 

 

 

 

USER DEFINED PARAMETERS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Parameter

Definition

 

 

 

 

 

P.99

Show Test Modes

 

 

 

 

 

 

 

Most power sources contain weld modes used for calibration and test purposes. By default, the machine

 

 

 

 

 

 

does not include test weld modes in the list of weld modes that are available to the operator. To manually

 

 

 

 

 

 

select a test weld mode, set this option to "Yes". When the power source is turned off and back on again,

 

 

 

 

 

 

the test modes will no longer appear in the mode list. Test weld modes typically require the machine out-

 

 

 

 

 

 

put to be connected to a grid load and cannot be used for welding.

 

 

 

 

 

 

 

 

 

 

 

 

P.100

View Diagnostics

 

 

 

 

 

 

 

Diagnostics are only used for servicing or troubleshooting the Power Wave system.

 

 

 

 

 

 

Select "Yes" to access the diagnostic options in the menu. Additional parameters will

 

 

 

 

 

 

now appear in the setup menu (P.101, P.102, etc).

 

 

 

 

 

 

 

 

 

 

 

 

P.101

View Event Logs

 

 

 

 

 

 

 

Used for viewing all the system event logs. Press the Right Button to enter the option. Rotate Control

 

 

 

 

 

 

Knob to select the desired event log to read. Press the Right Button again to enter the selected log.

 

 

 

 

 

 

Rotating the Control Knob will scroll through the event log, displaying the log index number, event code

 

 

 

 

 

 

and some other data. Press the Left Button to back out to select another log. Press the Left Button again

 

 

 

 

 

 

to exit this option.

 

 

 

 

 

 

 

 

 

 

 

 

P.102

View Fatal Logs

 

 

 

 

 

 

 

Used for viewing all the system fatal logs. Press the Right Button to enter the option. Rotate Control Knob

 

 

 

 

 

 

to select the desired fatal log to read. Press the Right Button again to enter that log. Rotating the Control

 

 

 

 

 

 

Knob will scroll through the log, displaying the log index number and fatal code. Press the Left Button to

 

 

 

 

 

 

back out to select another log. Press the Left Button again to exit this option.

 

 

 

 

 

 

 

 

 

 

 

 

P.103

View Software Version Information

 

 

 

 

 

 

 

Used for viewing the software versions for each board in the system. Press the Right Button to

 

 

 

 

 

 

enter the option. Rotate Control Knob to select the desired board to read. Press the Right

 

 

 

 

 

 

Button again to read the firmware version. Press the Left Button to back out to select another

 

 

 

 

 

 

board. Rotate the Control Knob to select another board, or press the Left Button to exit this

 

 

 

 

 

 

option.

 

 

 

 

 

 

 

 

 

 

 

 

P.104

View Hardware Version Information

 

 

 

 

 

 

 

Used for viewing the hardware version for each board in the system. Press the right MSP

 

 

 

 

 

 

Button to enter the option. Rotate Set knob to select the desired board to read. Press the right

 

 

 

 

 

 

button again to read the hardware version. Press the left button to back out to select another

 

 

 

 

 

 

board. Press the left button again to exit this option.

 

 

 

 

 

 

 

 

 

 

 

 

P.105

View Welding Software Information

 

 

 

 

 

 

 

Used for viewing the Weld Set in the Power Source. Press the Right Button to read the Weld

 

 

 

 

 

 

Set version. Press the Left Button to back out and exit this option.

 

 

 

 

 

 

 

 

 

 

 

 

P.106

View Ethernet IP Address

 

 

 

 

 

 

 

Used for viewing the IP address of Ethernet compatible equipment. Press the Right Button to

 

 

 

 

 

 

read the IP Address. Press the Left Button to back out and exit this option. The IP address can-

 

 

 

 

 

 

not be changed using this option.

 

 

 

 

 

 

 

 

 

 

 

 

P.107

View Power Source Protocol

 

 

 

 

 

 

 

Used for viewing the type of power source the feeder is connected to. Press the Right Button to

 

 

 

 

 

 

identify the power source as either LincNet or ArcLink. Press the Left Button to back out and

 

 

 

 

 

 

exit this option.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

POWER FEED™ 10M DUAL WIRE FEEDER

Image 30
Contents Safety Depends on You IM916Safety Electric Shock can kill Welding and Cutting Sparks can Cause fire or explosion IiiPrécautions DE Sûreté Sûreté Pour Soudage a L’ArcPlease Examine Carton and Equipment For Damage Immediately On-Line Product RegistrationTAbLE of Contents Section E ViiSection D Section FPower Feed 10M Dual Wire Feeder Welding Capacity RatingAmp Rating Duty Cycle Electrode Routing Safety PrecautionControl CAbLE Specifications Control CAbLE ConnectionsTAbLE A.1 Negative Electrode PolarityElectrode Sense Polarity Minimum CopperVoltage Sensing CAC-CWork Voltage Sensing Wire Drive Gear Ratio High or LOW SpeedSelecting the Proper Gear Ratio Electrode Voltage SensingGear Ratio Recognition Changing the Wire Drive Gear RatioGear Ratio Change Procedure TAbLE A.3With Standard Connection Wire Feed Drive Roll KitsProcedure to Install Drive Rolls and Wire Guides With FAST-MATECONNECTIONGeneral GUN Connection Guidelines Gmaw Shielding GASFlow Sensor Kit installation is as follows Wire Spindle PlacementWire Feed Shut Down Circuit Optional Water Connections for Water Cooled GunsExAMPLES of Connecting AN Arclink Power Wave System Safety Precautions Definitions of Welding ModesRecommended Processes Product DescriptionRecommended Processes and Equipment Recommended EquipmentWire Feed Speed WFS / AMP Meter Operational Features and ControlsPower FEED-10M Series System CONFIGURA- Tion Volt / Trim MeterOutput Controls Mode Select Panel 4 MSP4Dual Procedure / Dual Head Select W/MEMORY Panel OverviewSearching for a Weld Mode POWER-UP SequenceWeld Mode Searching LAYOUT-DIGITAL DisplayAccessing the Machine Setup Menu Limit SettingMachine SETUP/USER Preferences Changing ARC Wave ControlSET-UP Features Menu Parameter DefinitionUser Defined Parameters Parameter Definition Procedure Change Method Stall Factor AdjustmentReset Consumable Weight Parameter Definition Gun Offset AdjustmentCrater Delay TIG Gas ControlDisplay Trim as Volts Option Arc Start/Loss Error TimeParameter Definition Push-Pull Gun Knob behavior Sense From StudsParameter Definition Show Test Modes 100 View Diagnostics107 View Power Source Protocol 102 View Fatal Logs505 Setup Menu Lock 503 Memory button Disable504 Mode Select Panel Lock Parameter Definition 501 Encoder LockoutOnly be accessed using Power Wave Manager software Parameter Definition 506 Set User Interface Passcode509 UI Master Lockout Figure B.4 Memory Dual Head / Dual Procedure with MemoryDual Procedure / Head Select Saving to MemoryStep / 4 Step Operation Cold FEED/GAS Purge Switch Foot Amptrol Wire Reel Loading READI-REELS, Spools or CoilsHOT Inch Electrode PolarityFigure b.1 Procedure for Setting Angle of Feedplate AdjustmentDrive Roll Pressure Setting GAS Guard Regulator SettingWire Reel Changing Wire Feed Overload ProtectionMaking a Weld Component Status Lights Status Light StatesStatus Light States CON’T Low Limit Limit SettingHigh Limit AttributeCored Electrode Aluminum ElectrodeRoll DH Drive 4-Driven K1504-1 Coil Adapter K162-1 Wire Spindle AdapterField Installed OPTIONS/ACCESSORIES Optional Control Panel KitsK438 READI-REEL Adapter K435 Coil AdapterK363P READI-REEL Adapter Guns and GUN AdaptersK590-6 Water Connection KIT Dual Procedure Switch OptionsConduit Adapters K1536-1 Water Flow Sensor KITK1556-1 Light Duty Caster KIT K1733-1 Wire StraightenerK659-1 GAS Guard Regulator K1555-2 Insulated Lift HookMaintenance Routine MaintenancePeriodic Maintenance TROUbLESHOOTING TROUbLESHOOTING Field Service Facility PRObLEMS POSSIbLE CauseSymptoms Course of Action RecommendedTROUbLESHOOTING Either of these fail, the problem is With switch open and closed. If it Err 004 Err 001Err 003 Err 005Err 200 Err 020Err 100 Err 201Err 211 Err 212Three dashes Error Codes for the Power Wave ErrTROUbLESHOOTING Other Trol boardPower Feed 10M Dual Wire FeederPower Feed Dual Wire FeederL11044 DIAGRAMSF-4 Wire Drive Dimension Print Precaucion Warnung