Grizzly G0647, G0646 owner manual Circuit Requirements, 220/440V Operation, Full Load Amp Draw

Page 14

circuit requirements

SECTION 2: CIRCUIT REQUIREMENTS

220/440V Operation

Serious personal injury could occur if you connect the machine to the power source before you have completed the setup pro- cess. DO NOT connect the machine to the power source until instructed after setup.

Electrocution or fire could result if this machine is not installed to code. You MUST ensure compliance by checking with a quali- fied electrician!

NOTICE

The Model G0646/G0647 is prewired for 220V operation. If you plan to use your machine at 440V, you MUST have a quali- fied electrician perform the 440V conver- sion described on Page 13.

Full Load Amp Draw

G0646 220V 3-Phase

14.5A

Power Supply Circuit Requirements

You MUST connect your machine to a grounded circuit that is rated for the amperage given below. Never replace a circuit breaker on an existing cir- cuit with one of higher amperage without consult- ing a qualified electrician to ensure compliance with wiring codes.

If you are unsure about the wiring codes in your area or you plan to connect your machine to a shared circuit, consult a qualified electri- cian.

G0646/G0647 220V Minimum Circuit

20A

G0646/G0647 440V Minimum Circuit

15A

Power Connection Device

The power connection device depends on the type of installed or planned service. We recom- mend using one of the devices shown in Figure 5, depending on the model and voltage being used.

��������

����������

220V

NEMA 15-20

�������Plug & Receptacle

��������

������

�������������

Hardwired Locking

Disconnect Switch

G0646 440V 3-Phase

7.5A

������� �������

�� ��

for 440V, 3-Phase

G0647 220V 3-Phase

16A

G0647 440V 3-Phase

8A

������� ������������

Figure 5. Recommended connection types.

NOTICE

Phase Converter Precaution

The power from the manufactured leg of a phase converter may damage electrical components if connected to the wrong incoming power terminal on your machine. Only connect the manufactured leg to the T3 terminal of the main power switch (see Page 53 for identification).

-12-

NOTICE

Extension Cords (220V Only)

Using extension cords may reduce the life of the motor. Instead, place the machine near a power source. If you must use an extension cord:

Use at least a 12 gauge cord that does not exceed 50 feet in length.

Ensure that the extension cord contains a ground wire and plug pin.

G0646/G0647 50/65 Ton Ironworker

Image 14
Contents 50/65 TON Ironworker Page Table of Contents Contact Info IntroductionForeword Functional Overview Identification G0646 Machine Data Sheet G0646/G0647 50/65 Ton Ironworker G0647 Machine Data Sheet G0646/G0647 50/65 Ton Ironworker Safety Instructions for Machinery G0646/G0647 50/65 Ton Ironworker Additional Safety Instructions for Ironworkers Additional Safety Instructions for Hydraulics Circuit Requirements Power Supply Circuit RequirementsPower Connection Device 220/440V OperationTo rewire the Model G0646/G0647 for 440V operation 440V ConversionItems Needed for Setup SetupSetup Safety UnpackingInventory Clean Up Inventory Figure QtyMoving & Placing Base Unit Placement LocationSite Considerations Floor LoadBolting to Concrete Floors Using Machine MountsMounting to Shop Floor Test Run To test run the machineRecommended Adjustments Factory adjustments that should be verifiedBasic Controls Operation SafetyOperations Punching Using the Punching StationOperation Tips Motor Stop Button Turns the motor OFFTo remove punch tooling Removing/Installing Punch ToolingTools Needed Qty To install punch tooling Punch, adapter, retaining ring, Die installedBolster Mounting Hex Bolts 4 shown Notching Using the Notching StationRemoving & Installing Notch Dies To install the notch dies Notch Die ClearancesPage Flat Stock Shearing To avoid tooling or workpiece breakageTo shear flat stock Bar Stock Shearing To shear bar stockMaking a 90 Cut Extension BarAngle Iron Shearing Making a Less Than 90 Cut Adjusting Stroke Length Beam Lubrication T20448T20452 T20501 T20456 H0736 AccessoriesH7379-Tapmatic#1 Gold 16 oz H7380-Tapmatic#1 Gold 1 Gal Available Tooling Schedule MaintenanceCleaning Protecting Beam Pivot Shaft Shearing Hold-Down Adjustment RodLubrication Support Frame Lubrication Fluid Capacity Hydraulic SystemFilling Hydraulic Reservoir To drain and re-fill the hydraulic reservoir Draining & Re-Filling HydraulicReservoir Beam Alignment To align the beamMotor & Electrical ServiceTroubleshooting Operations Flat Stock Shearing Dies To remove and replace the flat stock shearing diesAngle Iron Shearing Dies To remove the angle iron shearing diesBar Stock Shearing Dies To remove and replace the bar stock shearing diesDisconnect Machine from Power Shearing Table Alignment Hydraulic Fluid Pressure To reset the position of the limit ringsLimit Rings Electrical Panel Wiring Control Panel Wiring Electrical Panel Wiring Diagram Control Panel Wiring Diagram Electrical Components Wiring Diagram Limit switch wiringMotor Wiring Diagram Motor wiring G0646/G0647 50/65 Ton IronworkerHydraulic System Overview Parts G0646 Upper Front-Half Parts List DescriptionG0647 Upper Front-Half Parts List Upper HalfG0646 Upper Rear-Half Parts List G0647 Upper Rear-Half Parts List DescriptionCabinet G0646 Cabinet G0647 Cabinet Notching Station Punching Station Extension Bar & Tools Label Placement Page Page Warranty and Returns