INSTALLATION AND BREAK-IN PROCEDURES

Piping

Plastic or PVC pipe is not designed for use with compressed air. Regardless of its indi- cated pressure rating, plastic pipe can burst from air pressure. Use only metal pipe for air distribution lines.

Note

Where a remote air intake is used, en- large the size of the air intake piping by one pipe size for each 10 feet of length.

A typical compressed air distribution system as shown below should be of sufficient pipe size to keep the pressure drop between the supply and point of use to a minimum. All pipes and fittings used must be certified safe for the pressures involved. Pipe thread sealant must be used on all threads, and all joints are to be made up tight, since small leaks in the piping system are the largest single cause of high operating costs.

All piping should be sloped to an accessible drain point and all outlets should be taken from the top of the main distribution air line so that moisture cannot enter the outlet.

The main distribution air line should not be smaller than the compressor air discharge valve outlet. A smaller line will restrict the flow of air. If piping is over 100 feet long, or if required air flow will exceed 15 SCFM, use 3/4" piping.

Note

For underground installation, bury air lines below the frost line and avoid pockets where condensation can gather and freeze. Apply pressure before un- derground lines are covered to make sure all pipe joints are free from leaks.

It is recommended that a flexible coupling be installed between the air discharge valve outlet and main air distribution line to allow for vibration.

To remove dirt, oil and water, install a separator in the main distribution line. Install separator a minimum of 5 to 6 feet from compressor to allow the air to cool to room temperature before passing through the separator. Addi- tional separators or filters may be used depending on the application.

Liquid water occurs naturally in air lines as a result of compression. Moisture vapor in ambient air is concen- trated when pressurized and condenses when cooled in downstream air piping. Compressed air dryers reduce the water vapor concentration and prevent liquid water formation in compressed air lines. Dryers are a neces- sary companion to filters, aftercoolers, and automatic drains for improving the productivity of compressed air systems.

Water and water vapor removal increases the efficiency of air operated equipment, reduces contamination and rusting, increases the service life of pneumatic equip- ment and tools, prevents air line freeze-ups, and reduces product rejects. The use of dryers and filters are recom- mended when these moisture related problems are reported to our factory or distributor service department.

MGP-SL10120H-2A

12—ENG

Image 12
Contents OUR Office Hours are from Monday Through FridayTable of Contents What can Happen HOW to Prevent IT Risk of Explosion or FireRisk of Bursting Risk from Flying Objects Risk to BreathingRisk of Electrical Shock Risk of Property Damage When Transporting Compressor Risk from Moving PartsRisk of Burns Risk of FallingSpecifications GlossaryDuty Cycle General Information ON-RECEIPT InspectionDescription of Operation Installation and BREAK-IN Procedures Horizontal UnitsWiring Instructions Wiring of Compressor UnitsVoltage and Circuit Protection Air Filter Installation Break-In ProceduresAdditional Regulators Controls Lubrication and OilPiping Operating Procedures When You Are FinishedMaintenance Routine Maintenance ScheduleService Instructions Air Filter Inspection ReplacementOil Chart Check Valve Inspection and ReplacementAdjusting Belt Tension Safety Valve Inspection and ReplacementAdditional Service Storage of Compressor OutfitMotor Pulley and Flywheel Alignment Troubleshooting Guide Problem Cause CorrectionFuses. Time delay fuses should be marked 117-207 ft.-lbs No adjustment is necessary Compressor Diagram Compressor Parts List Key Part Number DescriptionCompressor Pump Diagram Parts List Service Notes Limited Warranty This Warranty does not CoverWarranty Manual DEL Operador Para Compresor DE Aire DE DOS Etapas Diagrama DE LA Bomba Compresora Tabla DE ContenidosInstalación Y Procedimientos Guía Para DiagnósticoRiesgo DE Explosión ¿QUÉ Puede OCURRIR? ¿CÓMO PREVENIRLO?Riesgo DE Objetos Arrojados POR EL Aire Riesgo DE InhalaciónRiesgo DE Descarga Eléctrica Riesgo DE Partes Móviles Riesgo DE QuemadurasRiesgo DE Caidas Riesgo DE Daños a LA Propiedad AL Transportar EL CompresorEspecificaciones GlosarioCiclo DE Trabajo Información General Inspección AL RecibirDescripción DE LA Operación Procedimientos Para LA Instalación Y Asentamiento Ubicación del Compresor de AireMétodos de Anclaje para el Compresor de Aire Unidades HorizontalesInstrucciones para el Cableado Voltaje y Protección del CircuitoCableado de las Unidades Compresoras Ensamblaje del Filtro de Aire Procedimientos para el AsentamientoControles y Reguladores Adicionales Aceite y LubricaciónTuberías Cm de diámetroProcedimientos Para Operar Al TerminarMantenimiento Programa de Mantenimiento RutinarioInstrucciones Para EL Servicio Filtro de Aire Inspección y ReemplazoAceite Inspección y Cambio Tabla de AceiteVálvula de Seguridad Inspección y Reemplazo Válvula DE SeguridadInstrucciones Para EL Almacenaje DEL Compresor Regulación de la Tensión de la CorreaPoleas Propulsora y Volante Alineamiento Servicio AdicionalGuía Para Diagnóstico DE Problemas Problema Causa SoluciónDefectuoso Remplazo si fuese necesario Correcto. Referirse a la sección de Aceite y Asistencia adicional Diagrama DEL Compresor Lista DE Partes DEL Compresor Número EN Número DE Diagrm Parte DescripciónDiagrama DE LA Bomba DEL Compresor Lista DE Partes DE LA Bomba Compresora Número Diagrm DE Parte DescripciónNotas DE Servicio Garantía Limitada Esta Garantía no CubreGarantía