DeVillbiss Air Power Company MGP-SL10120H-2A, L10120H2-2 owner manual 117-207 ft.-lbs

Page 20

TROUBLESHOOTING GUIDE

PROBLEM

CAUSE

CORRECTION

 

 

 

 

Compressor is not supplying

Loose belt.

Adjust belt tension.

enough air to operate accesso-

Hole in hose.

Check and replace if required.

ries. (Continued)

 

Check valve restricted.

Remove and clean or replace.

 

Air leaks.

Tighten fittings. (See "Air Leaks" section of "Trou-

 

 

bleshooting Guide".)

 

 

 

 

Knocking noise.

Defective check valve.

Remove and clean or replace.

 

Loose pulley.

Tighten pulley set screw, 145 to 165 in.-lbs.

 

Low oil level.

Maintain prescribed oil level. Add oil.

 

Loose flywheel.

Tighten screw, 33 to 37 ft.-lbs.

 

Loose compressor mounting screws.

Check screws. Tighten as required.

 

Belt too tight/too loose.

Adjust belt tension. (See Belt Replacement.)

 

Carbon build-up.

Remove the head. Clean the valves and the top of the

 

 

piston. (Be sure carbon does not fall into the cylinder.)

 

 

Reassemble using new gaskets and torque screws,

 

 

117-207 ft.-lbs.

 

 

 

 

Excessive oil consumption.

Restricted air intake.

Replace the air intake.

 

Compressor overworked.

Reduce air consumption or add another air compres-

 

 

sor to take up some of the load.

 

Poor quality oil.

Drain pump and replace with correct oil. Refer to

 

 

Lubrication and Oil Section.

 

 

 

 

Compressor overheating.

The compressor is overworked.

Reduce air consumption or add another air compres-

 

 

sor to take up some of the load.

 

The check valve is restricted.

Inspect the check valve. Clean if necessary.

 

Dirty compressor.

Clean the compressor thoroughly.

 

High ambient temperature.

Use remote air intake.

 

 

 

 

Motor overheating.

Incorrect oil, low oil.

See oil recommendation under Maintenance.

 

Compressor starting against load.

Dirty or defective check valve.

 

Low voltage.

Provide correct voltage. Consult local power com-

 

 

pany or electrician.

 

Pressure switch set beyond factory set-

Do not set switch beyond maximum for which outfit

 

ting.

was designed as noted on nameplate.

 

Belt too tight.

Adjust for proper tension.

 

Compressor valves have excessive car-

Clean or replace compressor valves or check valve.

 

bon deposits build-up; restricted check

 

 

 

valve.

 

 

 

 

 

 

MGP-SL10120H-2A

20—ENG

Image 20
Contents OUR Office Hours are from Monday Through FridayTable of Contents Risk of Bursting What can Happen HOW to Prevent ITRisk of Explosion or Fire Risk of Electrical Shock Risk from Flying ObjectsRisk to Breathing Risk of Property Damage When Transporting Compressor Risk from Moving PartsRisk of Burns Risk of FallingDuty Cycle SpecificationsGlossary General Information ON-RECEIPT InspectionDescription of Operation Installation and BREAK-IN Procedures Horizontal UnitsVoltage and Circuit Protection Wiring InstructionsWiring of Compressor Units Air Filter Installation Break-In ProceduresAdditional Regulators Controls Lubrication and OilPiping Operating Procedures When You Are FinishedMaintenance Routine Maintenance ScheduleService Instructions Air Filter Inspection ReplacementOil Chart Check Valve Inspection and ReplacementAdjusting Belt Tension Safety Valve Inspection and ReplacementMotor Pulley and Flywheel Alignment Additional ServiceStorage of Compressor Outfit Troubleshooting Guide Problem Cause CorrectionFuses. Time delay fuses should be marked 117-207 ft.-lbs No adjustment is necessary Compressor Diagram Compressor Parts List Key Part Number DescriptionCompressor Pump Diagram Parts List Service Notes Limited Warranty This Warranty does not CoverWarranty Manual DEL Operador Para Compresor DE Aire DE DOS Etapas Diagrama DE LA Bomba Compresora Tabla DE ContenidosInstalación Y Procedimientos Guía Para DiagnósticoRiesgo DE Explosión ¿QUÉ Puede OCURRIR? ¿CÓMO PREVENIRLO?Riesgo DE Descarga Eléctrica Riesgo DE Objetos Arrojados POR EL AireRiesgo DE Inhalación Riesgo DE Partes Móviles Riesgo DE QuemadurasRiesgo DE Caidas Riesgo DE Daños a LA Propiedad AL Transportar EL CompresorCiclo DE Trabajo EspecificacionesGlosario Información General Inspección AL RecibirDescripción DE LA Operación Procedimientos Para LA Instalación Y Asentamiento Ubicación del Compresor de AireMétodos de Anclaje para el Compresor de Aire Unidades HorizontalesCableado de las Unidades Compresoras Instrucciones para el CableadoVoltaje y Protección del Circuito Ensamblaje del Filtro de Aire Procedimientos para el AsentamientoControles y Reguladores Adicionales Aceite y LubricaciónTuberías Cm de diámetroProcedimientos Para Operar Al TerminarMantenimiento Programa de Mantenimiento RutinarioInstrucciones Para EL Servicio Filtro de Aire Inspección y ReemplazoAceite Inspección y Cambio Tabla de AceiteVálvula de Seguridad Inspección y Reemplazo Válvula DE SeguridadInstrucciones Para EL Almacenaje DEL Compresor Regulación de la Tensión de la CorreaPoleas Propulsora y Volante Alineamiento Servicio AdicionalGuía Para Diagnóstico DE Problemas Problema Causa SoluciónDefectuoso Remplazo si fuese necesario Correcto. Referirse a la sección de Aceite y Asistencia adicional Diagrama DEL Compresor Lista DE Partes DEL Compresor Número EN Número DE Diagrm Parte DescripciónDiagrama DE LA Bomba DEL Compresor Lista DE Partes DE LA Bomba Compresora Número Diagrm DE Parte DescripciónNotas DE Servicio Garantía Limitada Esta Garantía no CubreGarantía