DeVillbiss Air Power Company L10120H2-2 owner manual General Information, ON-RECEIPT Inspection

Page 7

GENERAL INFORMATION

You have purchased a complete compressor outfit con- sisting of an air compressor, air tank, electric motor, and associated controls and instruments. The outfit you have selected is a stationary model and contains a two stage air compressor pump.

Your new compressor outfit can be used for operating paint sprayers, air tools, grease guns, air brushes, caulk- ing guns, sandblasters, inflating tires, etc.

An air pressure regulator is usually necessary for most applications. An air line filter is normally required for removal of moisture and oil vapor in compressed air when a paint spray gun is used.

An in-line lubricator is often required for air tools to prolong tool life.

Separate air transformers which combine the functions of air regulation and/or moisture and dirt removal should be used where applicable.

A regularly scheduled program of preventive mainte- nance will help provide the long life that has been designed into your compressor outfit. Before operating or performing any maintenance on your compressor, refer to this manual. To keep your compressor in good working order, refer to these publications often and perform preventive maintenance steps as recommended.

ON-RECEIPT INSPECTION

Each air compressor outfit is carefully checked before shipment. With improper handling, damage may result in transit and cause problems in compressor operation.

Immediately upon arrival, check equipment for both concealed and visible damages to avoid expenses being incurred to correct such problems. This should be done regardless of any visible signs of damage to the shipping container. Report any damages to carrier and arrange for inspection of goods immediately.

For the location or a listing of the nearest DeVilbiss Air Power Authorized Warranty Service Center, call our toll free number at 1-800-888-2468.

7—ENG

MGP-SL10120H-2A

Image 7
Contents Monday Through Friday OUR Office Hours are fromTable of Contents Risk of Explosion or Fire What can Happen HOW to Prevent ITRisk of Bursting Risk to Breathing Risk from Flying ObjectsRisk of Electrical Shock Risk of Falling Risk of Property Damage When Transporting CompressorRisk from Moving Parts Risk of BurnsGlossary SpecificationsDuty Cycle ON-RECEIPT Inspection General InformationDescription of Operation Horizontal Units Installation and BREAK-IN ProceduresWiring of Compressor Units Wiring InstructionsVoltage and Circuit Protection Lubrication and Oil Air Filter InstallationBreak-In Procedures Additional Regulators ControlsPiping When You Are Finished Operating ProceduresRoutine Maintenance Schedule MaintenanceCheck Valve Inspection and Replacement Service InstructionsAir Filter Inspection Replacement Oil ChartSafety Valve Inspection and Replacement Adjusting Belt TensionStorage of Compressor Outfit Additional ServiceMotor Pulley and Flywheel Alignment Problem Cause Correction Troubleshooting GuideFuses. Time delay fuses should be marked 117-207 ft.-lbs No adjustment is necessary Compressor Diagram Key Part Number Description Compressor Parts ListCompressor Pump Diagram Parts List Service Notes This Warranty does not Cover Limited WarrantyWarranty Manual DEL Operador Para Compresor DE Aire DE DOS Etapas Guía Para Diagnóstico Diagrama DE LA Bomba CompresoraTabla DE Contenidos Instalación Y Procedimientos¿QUÉ Puede OCURRIR? ¿CÓMO PREVENIRLO? Riesgo DE ExplosiónRiesgo DE Inhalación Riesgo DE Objetos Arrojados POR EL AireRiesgo DE Descarga Eléctrica Riesgo DE Daños a LA Propiedad AL Transportar EL Compresor Riesgo DE Partes MóvilesRiesgo DE Quemaduras Riesgo DE CaidasGlosario EspecificacionesCiclo DE Trabajo Inspección AL Recibir Información GeneralDescripción DE LA Operación Unidades Horizontales Procedimientos Para LA Instalación Y AsentamientoUbicación del Compresor de Aire Métodos de Anclaje para el Compresor de AireVoltaje y Protección del Circuito Instrucciones para el CableadoCableado de las Unidades Compresoras Aceite y Lubricación Ensamblaje del Filtro de AireProcedimientos para el Asentamiento Controles y Reguladores AdicionalesCm de diámetro TuberíasAl Terminar Procedimientos Para OperarPrograma de Mantenimiento Rutinario MantenimientoTabla de Aceite Instrucciones Para EL ServicioFiltro de Aire Inspección y Reemplazo Aceite Inspección y CambioVálvula DE Seguridad Válvula de Seguridad Inspección y ReemplazoServicio Adicional Instrucciones Para EL Almacenaje DEL CompresorRegulación de la Tensión de la Correa Poleas Propulsora y Volante AlineamientoProblema Causa Solución Guía Para Diagnóstico DE ProblemasDefectuoso Remplazo si fuese necesario Correcto. Referirse a la sección de Aceite y Asistencia adicional Diagrama DEL Compresor Número EN Número DE Diagrm Parte Descripción Lista DE Partes DEL CompresorDiagrama DE LA Bomba DEL Compresor Número Diagrm DE Parte Descripción Lista DE Partes DE LA Bomba CompresoraNotas DE Servicio Esta Garantía no Cubre Garantía LimitadaGarantía