Aurora Electronics PVI-3600-OUTD-UK-F-W manual Inverter

Page 13

Installation and Operator’s Manual

 

 

 

Page 13 of 63

(PVI-3600-OUTD-UK-F-W Rev.: 1.0)

 

 

 

 

 

Aurora Wind Inverter

 

 

Aurora Wind

DC/DC Boost Converter

High Voltage DC Bus

 

 

 

Grid Interface Inverter

CB1

 

Inteface Box

 

 

 

K1

20 A

 

20 A

 

 

 

 

PMSG

 

 

 

Line Filter

To

 

 

 

 

Distribution

 

 

 

 

 

 

Panelboard

 

 

 

 

 

 

Breaker

 

PMG

3.6 kW

 

3.6 kW

 

 

 

input

 

 

 

 

 

 

 

 

 

Voc

= 400 V max.

Gate Drive Board

Gate Drive Board

 

Vnom

= 360 V nom.

 

 

Vmin = 40

 

 

 

 

 

 

 

 

Optoisolation

 

 

 

Load Bank

 

 

 

 

 

 

(Optional)

DC Current Feedback

Inverter

Inverter Current Feedback

 

 

 

 

 

 

 

 

Inverter

 

 

 

 

 

Embedded

 

 

 

 

Generator Voltage Feedback

Embedded

Grid Voltage Feedback

 

 

 

 

Controller

 

 

 

 

 

Controller

 

 

 

 

Operator

 

 

 

 

 

 

Interface

 

 

 

 

 

 

 

2 - line LCD

Reset

 

Fig.4 AURORA block diagram

The block diagram shows the model AURORA PVI-3600-OUTD-UK-F-W with its two input Dc-Dc converters. The two Dc-Dc converters are controlled in parallel by the Wind maximum power point tracker control.

Thanks to its high efficiency and large heat-sink, AURORA offers max. power operation over a wide ambient temperature range.

The inverter is digitally controlled by means of two independent Digital Signal Processors (DSP), and one microprocessor.

Two single-chip independent computers maintain control in full compliance with the electric standards relating to systems power supply and safety.

The AURORA operating system performs inter-process communication checks to ensure the entire unit operates properly.

Image 13
Contents AURORA Revision Table Important Safety InstructionsImportant Safety Instructions Assembly Useful Information and Safety Standard ForewordGeneral Electrical Connection Maintenance and ServiceOperation Save ALL Documents in a Safe PlacePVI-3600-OUTD-UK-F-W Contents Page Wind Energy Main Elements of a Wind System Simplified diagram of a Wind system Aurora Technical Description Data Transmission and CheckInverter Protective Devices Anti-Islanding Ground FaultFurther Protective Devices System Design Package Inspection Package Check List Description Quantity No Minimum clearance requirements Choosing Installation LocationWall Mounting Wall mounting diagramPage Inverter tilted mounting Preliminaries to Electrical Connections General wiring diagram Position of the holes on the bottom side Removing the side panel Page Location of Main Ground PE Screw Aurora Connect Aurora to the Dc disconnect switchesPV Input Close the side panel START-UP User’s Interface Mode Data Transmission Options Real time data Available DataInternally Logged Data KEY LED IndicatorsLED on LED blinking LED off Any of the above conditions Installation phase Aurora is disconnected from grid Aurora Initialization and Grid Check Sleep ModeAurora Under Production Ground InsulationRS-485 Address Setting Signal Malfunction-Fault SignalMessages and Error Codes Error Description LCD Display Second screen Serial Number and Firmware release number Pac ## W Vin Timegrid hhmmss Numgrid ## Error Grid fail Data RS-485 serial link Multiple units connection Data transmission to a PC Power Line Modem PLMData transmission to Aurora Easy Control Display menù Manual address settingAddress Information Verifying the paralleled input configuration Automatic settingSET in Mode Parallel Data Description Unit Measurement AccuracyData Resolution Accuracy Display Measurement Troubleshooting Info Aurora Input Values PVI-3600-OUTD-UK-F-W ValueOutput Values Description Grid protection characteristicsGeneral characteristics Description Value Power Derating due to Ambient Temperature Power DeratingPower Derating due to Input Voltage